12.07.2015 Views

Accuron 7700 - Eastech Flow Controls

Accuron 7700 - Eastech Flow Controls

Accuron 7700 - Eastech Flow Controls

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ACCURON ® <strong>7700</strong>PARTIALLY FILLED CLOSED PIPESInline Cartridge MetersThe <strong>Accuron</strong> <strong>7700</strong> is an Inline CartridgeMeter specifically designed for partiallyfilled closed pipe applications. A 304stainless steel spool-type Cartridge,incorporating a trapezoidal flume,ultrasonic level sensor, and a pair of transittimevelocity sensors is manufactured tomeet exact customer laying length and endconnection specifications. During periods of minimal flow (Zero to 1/3 pipe),measurements are achieved through a highly efficient combination ofa trapezoidal flume (traceable to Bureau of Reclamation WinFlumestandards) and an ultrasonic level sensor enclosed within an “above theflow” protective casing. During periods of maximum flow (1/3 to fullpipe), measurements are achieved through proven area-velocity methodsby combining a pair of chordal transit-time velocity sensors with the same“above the flow” ultrasonic level sensor.The bi-directional transit-time velocitysensors also allow for monitoring of reverse and stagnant flow conditions.Each Cartridge is provided with an inspection port located directly above thetrapezoidal flume for calibration verification. Should the need ever arise forcleaning or replacement of a sensor, level sensor access is provided througha flange located on top of the protective casing. Velocity sensors are simplyremoved and cleaned through the utilization of isolation ball valves integratedwithin each sensor housing.This highly efficient maintenance feature eliminatesthe requirement for Cartridge removal or dewatering of the system.LOW FLOW(0 to 1/3 Pipe)HIGH FLOW(1/3 to Full Pipe)Level SensorInspectionPortTrapezoidalFlumeVelocity Sensors304 StainlessCartridgeVelocity SensorsPVC/304 StainlessSensor CableTriax w/PVC CoatingCable LengthMax: 1000 feetOperating Temp. -40° F to 158° F (-40° C to 70° C)Ball Valve Bronze (2”)Level SensorPVCSensor Cable4 Cond. w/PVC CoatingCable LengthMax: 1000 feetOperating Temp. -40° F to 158° F (-40° C to 70° C)


METER SPECIFICATIONS (Bi-directional)FACTORYPROGRAMMEDFLOWMETERSPre-programmed at thefactory for specific customerapplications, the <strong>Accuron</strong> flowmeter is a highly advancedmicroprocessor-based ultrasonic flow transmitter forextremely precise measurement of flow in open channels.DATA LOGGINGThe <strong>Accuron</strong> has a built-in datalogger with eight distinct channels for loggingflow and totals.The storage capacity for a single channel at 5 minute intervalsis 113 days. Logger data may be visually accessed on the display of the meterin pre-programmed time intervals or retrieved through a laptop or optionalmodem installed within the enclosure of the meter.Daily Averages: Daily summary allows viewing of the previous eightdays. This includes times, dates, averages, minimums, maximums and totals.Logger Graph: In addition, a bar graph may be visually displayed on the<strong>Accuron</strong>. The graph will display the stored logger data in pre-programmedtime intervals.Data Retrieval: Logger data can be collected by using a laptopcomputer or an optional modem installed within the <strong>Accuron</strong> enclosure.ENCLOSUREStandardIP66 / Nema 4, 4X polycarbonate enclosureOptionalExplosionproof, Aluminum EnclosureClass I ,Grps. C & D, Class II, Grps. E, F, G. Div. 1 & 2AccessoriesHeater and thermostat, Door LockTEMPERATUREStandard-4° to 158°F (-20 to 70°C)With Heater-40° to 158°F (-40 to 70°C)OUTPUTS3) 4-20 mA Analog isolated into 800 ohms max, monitored(<strong>Flow</strong>, Level,Velocity) to detect open circuits. RFI and gasdischarge surge protection and two fuses.Relay Alarms3 SPDT (plug-in) 2.5 AmpsRS-232 Serial Port 1200-38400 Baud, Modbus RTURS-485 Serial Port Optically isolated, Modbus RTUNetwork Protocols Modbus, Profibus or DeviceNetDC Power Out12 VDC. 100mA maximumDISPLAYBacklit LCDGraphical LEDPOWERWattage 30Voltage80/240 VAC, 50/60 Hz / 12-28VDC @ 550 mA.DATA LOGGINGNon-volatile flash memory, storage of up to 32768 records.SUGGESTED SPECIFICATIONS: An ultrasonic microprocessor-based Inline Cartridge Meter shall be installed at the location on the plans in accordancewith the manufactures recommendation. A field-ready___________(pipe size) stainless steel cartridge, containing a stainless steel trapezoidal flume/ultrasoniclevel sensor/transit-time velocity sensor combination shall be provided with each flowmeter. The IP66/Nema 4,4X flowmeter (or Chartmeter) shall be factoryprogrammed for the specific application and be provided with a datalogger integral to the electronics. The Cartridge Meter must be capable of field validation priorto installation of permanent power. The unit shall be Model <strong>Accuron</strong> <strong>7700</strong> as manufactured by <strong>Eastech</strong> <strong>Flow</strong> <strong>Controls</strong>, Tulsa, OK or equal.ORDERING GUIDECARTRIDGE METER NOMINAL OVERALL END SENSOR OPTIONS PROGRAM DATAPIPE SIZE LAYING LENGTH CONNECTIONS CABLE RETRIEVALCARTRIDGE 77Accuracy:(0 - 1/3 Pipe): ±1-5%(1/3 - Full Pipe): ±1-3%Turndown: 60:1Rangeability:40 to 0.1ft/secRepeatability:±2% of actual flowMETER 10Nema 4,4XIP663-4-20mARS232/4853 RelaysDataloggerBi-directionalSpecifyPipe I.D.PleaseSpecify30 ftW50 ft.X100 ft.Y200 ft.Z(Over 200 ft.pleasespecify)IntegratedChartRecorderCircular Chart1 Day7 Day31 Day(please specify)GHeater &ThermostatBKeylockCSplice KitDGal/Min.ACu. Ft./Sec.HMil.Gal/DayJLit./Sec.KGal./Hr.LOther(please specify)Modem(phone line)MProfibusEUpstreamDownstreamDevice-NetFwww.eastechflow.comeastechFLOW CONTROLS4250 S. 76th E. Ave.Tulsa, OK 74145email: info@eastechflow.com918-664-1212800-226-3569Fax: 918-664-8494

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!