manual<strong>FCS</strong>-<strong>30</strong>/<strong>60</strong>/<strong>150</strong> <strong>kg</strong> (3 olika vågar)PAKET OCH UNIVERSALVÅGNormal hanteringTryckknapparON/OFF Startar och stänger av vågen.HOLD hold-funktion som håller kvar viktsvärdet 2 minuter efter det vikten på vågenändratsUNIT Växlar mellan <strong>kg</strong> och lb.ZERO/TAREIndikatorerNollställer vågen över hela området 0 – <strong>30</strong>,00 / <strong>60</strong>,00 / <strong>150</strong>.0 <strong>kg</strong>.<strong>kg</strong>, lb, batterisymbol för låg matningsspänning, zero (stabil nollpunkt), en punkt tillvänster är tänd när vågen har holdfunktionen aktiverad. Vågen visar EEE när den äröverlastad.Auto power off (vågen stängs efter 2 minuter om inte viktvärdet ändrar sig eller någon knapptrycks in).Vid leverans har vågen vanligen denna funktion aktiverad. För att koppla ur den gör så här: TryckHOLD och håll kvar, tryck på ON, vågen visar A_ON. Tryck ZERO för att skifta till A_OFF. Tryck OFFoch ON.TYP KAPACITET GRADERING<strong>FCS</strong> <strong>30</strong><strong>kg</strong>/10g <strong>30</strong> <strong>kg</strong> 10 g<strong>FCS</strong> <strong>60</strong><strong>kg</strong>/20g <strong>60</strong> <strong>kg</strong> 20 g<strong>FCS</strong> <strong>150</strong><strong>kg</strong>/50g <strong>150</strong> <strong>kg</strong> 50 g upp till 100 <strong>kg</strong>, 100 g mellan 100 och <strong>150</strong> <strong>kg</strong>Storlek vågplatta:Netto / Bruttovikt:Arbetstemperatur:Matning:Utsignal:3<strong>30</strong> x 320 mm4,1 / 4,5 <strong>kg</strong> (Kartong 44,5x34,6x7 cm eller 5 st 46x36x39 cm)Optimalt 15-<strong>30</strong>°Cadapter 2<strong>30</strong> VAC / 9 VDC, 100 mA, +center eller 6 st AA batterier (ingår ej).RS232Nordens största webbshop för vågarBox 79, Industrivägen 37<strong>60</strong> 40 Väddö, SverigeTel. +46 (0)176-208920Fax +46 (0)176-208929Web www.vetek.seEmail info@vetek.seREVISION07.2010 1


manualSAFETY PRECAUTIONSAll safety messages are identified by the words “WARNING” and “CAUTION”. These words meanthe following: WARNING Important information to alert you to a situation that might cause seriousinjury and damage to your property if instructions are not followed.Use only the correct AC adaptor with the scale. Other adaptors may cause permanent electricaldamage.CAUTION• Important information that tells how to prevent damage to the equipment.• When using the scale, the following safety precautions should always be followed.• Avoid placing the scale in direct sunlight, this may cause discoloration or malfunction.• Replace all batteries at the same time – Do not replace only a portion of the 6 batteries asthis may cause a malfunction.• If the scale is not to be used for a long period of time, remove all batteries from the batterycompartment to avoid leakage, which may cause damage to this scale.• Avoid overloading the scale, as this may cause permanent damage and void your warranty– do not EVER exceed the maximum capacity of the scale• Keep the scale away from water – this scale is not water resistant. Shock, injury andelectrical damage can occur if used in a wet location!• Matter charged with static electricity could affect accuracy. Discharge all static electricity.For example, one method is to use Static-Guard spray, and spray it on both sides of theweighing platform.www.vetek.se info@vetek.se 2


manualFUNCTION SETTINGS1. Enter function setting mode.Press [ON/OFF] to turn the power off, Press [HOLD] first, then press [ON/OFF], while keeping [HOLD]pressed, the display will show A_ON or A_OFF.2. Selection of auto shut off mode.When the balance enter function setting menu. the display will show A_ON or A_OFF, Press [ZERO]key, selection display A_ON, this means auto shut off function active. Press [ZERO] again, thedisplay will show A_OFF, this means auto shut off function inactive.WEIGHINGBefore weighingWhenever possible, please allow the scale to warm up for several seconds after first turning thepower on so that the scale will function properly and accurately.Error messagesEEEE: OverloadLow batteryWeighing procedures1. Press [ON/OFF] to turn on the scale.When the power is turned on, all display segments appear for a few seconds and “0” will appear onthe display.2. Select the weighing unit with [UNIT]. Press [UNIT] to select a weighing unit “<strong>kg</strong>”, “lb”. Once theunit has been selected, the selected unit will be displayed next to the weight value.3. Start weighing If you do not use a container for weighing, Verify the reading is “0”. If not, press[ZERO/TARE] to display “0”. Place the items to be weighed on the platform. When the readingbecomes stable, the stable weighing is displayed. If you use a container for weighing,Place an empty container on the platform. Wait for the stability indicator to be displayed and press[ZERO/TARE]. Place the objects to be weighed in the container. When the reading becomes stable,the stable weighing displayed.CALIBRATIONWhen to calibrate - calibration is almost never required.If the scale is inaccurate, calibration may be desired when the scale is first set up for use, or if thescale is moved to a different altitude or gravitation. This is necessary because the weight of a massin one location is not necessarily the same in another location. Also, with time and use, mechanicaldeviations can occur.www.vetek.se info@vetek.se 4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!