12.07.2015 Views

EN.33.C.14_LK Wireless Room Control Cq 1, 4 & 6 ... - LK Systems AB

EN.33.C.14_LK Wireless Room Control Cq 1, 4 & 6 ... - LK Systems AB

EN.33.C.14_LK Wireless Room Control Cq 1, 4 & 6 ... - LK Systems AB

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Assembly instructions | <strong>LK</strong> <strong>Wireless</strong> <strong>Room</strong> <strong>Control</strong> <strong>Cq</strong> 1, 4 & 6 (NO)<strong>Cq</strong> 4 and <strong>Cq</strong> 6 <strong>Control</strong> UnitFor the <strong>Cq</strong> 4 and <strong>Cq</strong> 6 Receiver Unit, a maximumof 4 actuators can be connected to each channel.The circuit diagram shows that all channels in <strong>Cq</strong>4, and 2 channels in <strong>Cq</strong> 6, have double terminalboards, a or c respectively, for connecting the actuators.<strong>Cq</strong>4 and <strong>Cq</strong>6 receiver units can operate amaximum of 16 actuators.When connecting two or more actuators to thesame channel, the connections must be only tothe double circuit boards.channel 1 channel 2 channel 3 channel 4Supply AC 24V<strong>LK</strong> TransformerMMains AC 230V29NCircuit diagram <strong>Cq</strong> 1, (M = Actuator).<strong>LK</strong> Transformer 230/24 V ACA transformer 60 VA for 24V AC supply is connectedin accordance with the circuit diagram foreach receiver unit.MainsAC 230VSupply AC 24V<strong>LK</strong> TransformerCircuit diagram <strong>Cq</strong> 4, (M = actuator).channel 1 channel 2 channel 3 channel 4 channel 5 channel 6MainsAC 230VSupply AC 24V<strong>LK</strong> TransformerCircuit diagram <strong>Cq</strong> 6, (M = actuator).<strong>Cq</strong> 1 Receiver Unit<strong>Cq</strong> 1 Receiver Unit differs from the other units asup to eight actuators can be connected.230V mains voltage connection• Connect the receiver unit and the transformerto the mains.• Check the primary and secondary voltage.• Reassemble the protection box on the receiverunit before Memorizing/Start-up.Up to two actuators can be connected direct to<strong>Cq</strong>1. However, if necessary, it is possible to connectup to eight actuators to <strong>Cq</strong>1 by using an externalwiring/junction box. In both cases the actuatorsare connected parrallel to each other andin line between terminal 9 and the <strong>LK</strong> Transformer.<strong>EN.33.C.14</strong>.2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!