Hydrometer Sharky 773 Ultrasonic Compact Energy ... - hsa-asia.com

Hydrometer Sharky 773 Ultrasonic Compact Energy ... - hsa-asia.com

Hydrometer Sharky 773 Ultrasonic Compact Energy ... - hsa-asia.com

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DATASHEET ultrasonic <strong>com</strong>pact energy metermodel <strong>773</strong>ACCESSORIES/SOFTWAREThe HYDRO-SET parametrization software based on theM-Bus is a convenient tool for handling the meter. It runs onWINDOWS® 2000/XP and is used for:❑ taking meter into operation❑ reading out different memories❑ printing out meter logs❑ meter configurationFurther information about the HYDRO-SET software isavailable for free downloading from our website atwww.hydrometer.<strong>com</strong>/Systems/Downloadcenter.html❑ Reading the meter on a certain day.Example: If the day for reading is 01.10, the meter readingis displayed for the period from 01.10 of the previousyear to 30.09 of the current year.❑ Comparison of the last consumption period with the precedingperiodEVENT MEMORYEvents such as changes and faults are stored in a non-volatilememory with a capacity of up to 31 entries. The followingevents are recorded:❑ Checksum error❑ Temperature measurement error❑ <strong>Ultrasonic</strong> echo time measurement errors❑ Start and end of test modeMONTHLY MEMORYSHARKY has a history memory of 24 months. The followingvalues are stored in the EEPROM on the programmed date1 ... 31 via (HYDRO-SET) of the actual month:❑ Date/Time ❑ Volume❑ <strong>Energy</strong> ❑ Error day counter❑ Tariff energy 1 ❑ Maximum monthly flow rate❑ Tariff energy 2 ❑ Maximum monthly power❑ Tariff definition 1 ❑ Date of maximum monthly flow rate❑ Tariff definition 2 ❑ Date of maximum monthly power❑ Impulse input 1 ❑ Impulse input 2Table 1MAX. VALUESThe integrator creates max. values for power and flow ratebased on consumption time, which are stored in the EEPROM.The integration intervals are adjustable to 6, 15, 30 or 60minutes or 24 h. Default setting is 60 minutes.TARIFF FUNCTIONThe integrator offers two optional tariff memories for monitoringplant load states for limit tariffs. Extensive tariffconditions make it possible to adapt the meter individuallyto the required customer-specific applications.Apart from the energy a time-based tariff can also be programmed.The following limit types are possible:(This example applies to the display with 3 decimal places)LOG MEMORYThe log memory is used to store consumption values. Thestorage frequency can be selected from various storageintervals (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30, 60 minutes orthe default setting of 24 hours, see Table 1). The data savedin the log memory can be used for the following analyses:

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!