RangeResolutionFrequency(Hz)1 Yr Accuracy± (% of Reading+ % of Range)FUNCTIONAC Current (AC RMS Current)3-5Hz1.00% + 0.04%1.000000A1µA5-10Hz0.30% + 0.04%10-5kHz0.10% + 0.04%3-5Hz1.10% + 0.06%3.00000A10µA5-10Hz0.35% + 0.06%10-5kHz0.15% + 0.06%RangeResolutionTest Current1 Year Accuracy ±(% of Reading+ % of Range)FUNCTIONResistance100.0000Ω100µΩ1mA0.010% + 0.004%1.000000kΩ1mΩ1mA0.010% + 0.001%10.00000kΩ10mΩ100µA0.010% + 0.001%100.0000kΩ100mΩ10µA0.010% + 0.001%1.000000MΩ1Ω5µA0.010% + 0.001%10.00000MΩ10Ω500nA0.040% + 0.001%100.0000MΩ100Ω500nA0.800% + 0.010%Diode Test1.00000V10µV1mA0.010% + 0.020%Continuity1000.00Ω10mΩ1mA0.010% + 0.030%RangeFrequency1 Yr Accuracy± (% of Reading+ % of Range)FUNCTIONFrequency & Period3-5Hz0.10%100mV ~ 750V5-10Hz10-40Hz0.05%0.03%40-300kHz0.01%NOTE: Specification conditions are after 1 hour warm-up at 23°C ± 5°C at 6½ digits.M3500AFUNCTIONGeneralStandard InterfaceDimensions & WeightUSB85mm (H) x 210mm (W) x 350mm (D), 4.36kgStandard AccessoriesM3500-Opt01M3500-Opt02M3500-Opt03M3500-Opt04M3500-Opt05M3500-Opt06OPTIONS & ACCESSORIESCD (User Manual & Software Applications), Power Cable, Test Leads & USB Cable.Multi-Point Scanner Card.Thermal Adapter.BNC to Banana Adapter.GPIB Interface.RTD Probe Adapter.RS-232 Interface.114Tel: +44 (0)20 8868 1311 Fax: +44 (0)20 8866 65961-3 Kildare Close, Eastcote, Ruislip, Middlesex HA4 9UR
Bench Digital MultimetersGDM-8255 & GDM-8251• Up to 199999 Counts (Model GDM-8255).• Dual Colour VFD Display.• Auto/Manual Ranging.• Temperature Measurement.AVAILABLETO BUY ONLINEGDM-8255GDM-8251ResolutionSample RateDC VoltageAC VoltageTrue RMSDC CurrentAC CurrentTrue RMSResistanceOther FunctionsGeneralFull ScaleSlowMediumFastRangeAccuracyInput ImpedanceRangeAccuracyInput ImpedanceRangeAccuracyRangeAccuracyRange2 Wire Accuracy4 Wire AccuracyDiode TestFrequencyContinuity BeeperTemperatureOther FunctionsDisplayInterfacePower SourceAccessoriesDimensionsWeight199999 Counts100Ω, 1kΩ, 10kΩ, 100kΩ, 1MΩ, 10MΩ, 100MΩ, 7 Ranges100Ω Range : ± (0.1% Rdg + 8 Digits) (*) ; 1kΩ ~ 1MΩ 4 Ranges :± (0.08% Rdg + 5 Digits)10MΩ Range : ± (0.3% Rdg + 5 Digits) ; 100MΩ Range : ± (3% Rdg + 8 Digits)100Ω Range : ± (0.05% Rdg + 8 Digits) (*) ; 1kΩ ~ 1MΩ 4 Ranges:Ω (0.05% Rdg + 5 Digits)10MΩ Range : ± (0.3% Rdg + 5 Digits) ; 100MΩ Range : ± (3% Rdg + 8 Digits)Open Circuit Voltage 2.0V, Test Current 0.5mA20Hz ~ 300kHz1 ~ 1000Ω0°C ~ 300°C : J, K, T TypeAuto Range / Manual, Math : MX + B / % / 1 / X ; Max, Min, dBm, dB, REL,Hold, Compare, Store, RecallVFD, Two Colours, Dual DisplayStandard: Remote I/O, USB, RS-232C, Option: GPIB, Scanner CardAC 100V ~ 240V ± 10%, 50 / 60HzUser Manual x 1, Power Cord x 1, Test Lead GTL-118 x 1, Calibration KeyGDM-01 x 1 (Compatible with Fluke 5720A / 5725A Calibrators Only)265mm (W) x 107mm (H) x 350mm (D)2.6kgOPTIONS & ACCESSORIES5½ Digits, 10 Readings/Second4½ Digits, 30 Readings/Second3½ Digital, 60 Readings/Second120000 Counts100mV, 1V, 10V, 100V, 1000V, 5 Ranges±(0.012% Rdg + 5 Digits)10MΩ100mV, 1V, 10V, 100V, 750V, 5 Ranges20Hz ~ 45Hz: ± (1% Rdg + 10 Digits)45Hz ~ 10kHz : ± (0.2% Rdg + 100 Digits)10kHz ~ 30kHz : ± (1% Rdg + 100 Digits)30kHz ~ 100kHz : ± (3% Rdg + 200 Digits)10MΩ10mA, 100mA, 10A, 3 Ranges10mA, 100mA : ± (0.05% Rdg + 15 Digits)10A Range : ± (0.2% Rdg + 5 Digits)10mA, 100mA, 10A, 3 Ranges10mA, 100mA Range:20Hz ~ 50Hz : ± (1.5% Rdg + 100 Digits)50Hz ~ 10kHz : ± (0.5% Rdg + 100 Digits)10kHz ~ 20kHz : ± (2% Rdg + 200 Digits)Option 01Option 02GTL-108AGTL-245GPIB Interface (Factory Installed Only).GDM-SC1, 16 Channel Scanner Card.4 Wire Type Test Lead.Type A-A USB Cable.www.aspen-electronics.com sales@aspen-electronics.comFOR EQUIPMENT CALIBRATION DETAILS, CALL OUR SERVICE DEPARTMENT TODAY… 115