164.1.3 TYPICAL THROUGH THE CEILINGA. Move the stove into position with the fl ue centered, midpoint between twojoists to prevent having to cut them. Use a plumb bob to line up the center.B. Cut and frame an opening in the ceiling to provide a 2” clearance betweenthe outside of the chimney and any combustible material. DO NOT FILL THISSPACE WITH ANY TYPE OF MATERIAL.Nail headers between the joist for extra support.Firestop spacers must be placed on the bottomof each framed opening in any fl oor orceiling that the chimney passes through.If your chimney system is enclosed withinthe attic area, a rafter radiation shield isrequired.C. Hold a plumb bob from the underside ofthe roof to determine where the opening inthe roof should be. Cut and frame the roofopening to maintain proper 2” clearances.HEADERSFIRESTOP SPACER -UNDERSIDE OF JOISTNOTE: The chimney must be supported at the ceiling or roof so that it’sweight does not rest on the appliance and must comply with it’smanufacturer’s instructions.TERMINALLISTEDCHIMNEYSPECIFIEDCLEARANCEMAINTAIN 2”CLEARANCELISTED CHIMNEYSTORMCOLLARFLASHINGROOFINSULATIONCEILINGSUPPORTCHIMNEYSUPPORTTO STOVECONNECTIONDETAILCHIMNEYCONNECTORFLOORPROTECTORCOMBUSTIBLEWALL60.1AW415-0762 / B / 11.12.10