MountingMaterial coneIn silos <strong>with</strong> bulk solids, material cones can form which changethe switching point. Please keep this in mind when installingthe sensor in the vessel. We recommend selecting aninstallation location where the probe detects the average valueof the material cone.The measuring probe must be mounted in a way that takes thearrangement of the filling and emptying apertures into account.To compensate measurement errors caused by the materialcone in cylindrical vessels, the sensor must be mounted at adistance of d/6 from the vessel wall.d6d6ddFig. 5: Filling and emptying centered14 <strong>VEGACAP</strong> <strong>67</strong> - <strong>with</strong> <strong>two</strong>-<strong>wire</strong> <strong>output</strong>31317-EN-060223