12.07.2015 Views

IHE Patient Care Device Technical Framework

IHE Patient Care Device Technical Framework

IHE Patient Care Device Technical Framework

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1020<strong>IHE</strong> <strong>Patient</strong> <strong>Care</strong> <strong>Device</strong> <strong>Technical</strong> <strong>Framework</strong>, Vol. 2: Transactions________________________________________________________________________HL7 definition: This component specifies the code for the building where the personis located. After facility, it is the most general person location designation.HL7 user-defined table 0307 does not suggest any values. The codification ofbuildings shall be defined at the site level in acute care settings.Component 8: Floor (IS), required but may be empty:HL7 definition: This component specifies the code for the floor where the person islocated. After building, it is the most general person location designation.HL7 user-defined table 308 does not suggest any values. The codification of floorsshall be defined at the site level in acute care settings.Component 9: Location description (ST), required but may be empty:HL7 definition: This component describes the location in free text.Component 10: Comprehensive Location Identifier (EI), required but may be empty:HL7 definition: The unique identifier that represents the physical location as a wholewithout regard for the individual components. This accommodates sites that may havea different method of defining physical units or who may code at a less granular level.For example, point of care, room, and bed may be 1 indivisible code.Component 11: Assigning Authority for Location (HD), required but may be empty:HL7 definition: The entity that creates the data for the individual physical locationcomponents. If populated, it should be the authority for all components populated.Refer to HL7 User-defined Table 0363 - Assigning authority for suggested values forthe first sub-component of the HD component, .By site agreement, implementers may continue to use HL7 User-defined Table 0300 -Namespace ID for the first sub-component.C.6 TS Data Type30Table 34 TS: Time StampSEQ LEN DT Usage Card. TBL# Component name1 24 DTM R [1..1] Time2 1 ID X [0..0] 0529 Degree of PrecisionThe first subfield is required. It specifies a point in time.Maximum length: 24.HL7 Format: YYYY[MM[DD[HH[MM[SS[.S[S[S[S]]]]]]]]][+/-ZZZZ]Constrained format in this PCD profile: YYYY[MM[DD[HH[MM[SS]]]]][+/-ZZZZ]Rev. 1.1 TI: 2006-08-1561Copyright © 2005-2006: ACC, ACCE, HIMSS, and RSNA

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!