12.07.2015 Views

Balancer Diagnostic Codes - Snap-on Equipment

Balancer Diagnostic Codes - Snap-on Equipment

Balancer Diagnostic Codes - Snap-on Equipment

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

16. Check Optima outer scanner E364Affected models : Models with optima hardwareService <str<strong>on</strong>g>Codes</str<strong>on</strong>g> : C123Right side scanner self test fail or CCD not calibrated or zero mark not detected.Balancing is not possiblesince wheel data cannot be scanned.Problem during power up. Switch power off and <strong>on</strong> again. Shouldthe problem not go away please call service.17. Check Optima rear scanner E365Affected models : Models with optima hardwareService <str<strong>on</strong>g>Codes</str<strong>on</strong>g> : C123Rear scanner self test fail or CCD not calibrated or zero mark not detected.Wheel data can be scanned,balancing is possible. Run out measurement of the wheel is not possible.Problem during power up. Verifyif the scanner is <strong>on</strong> its rail. Switch power off and <strong>on</strong> again. Should the problem not go away please callservice.18. Check Optima main camera board memory E366Affected models : Models with optima hardwareService <str<strong>on</strong>g>Codes</str<strong>on</strong>g> : C123Possible causes: there is a fault in the camera c<strong>on</strong>troller boardCorrective acti<strong>on</strong>s: check the camera c<strong>on</strong>troller board19. Check Optima motor power supply E367Affected models : Models with optima hardwareService <str<strong>on</strong>g>Codes</str<strong>on</strong>g> : C123Possible causes: -Corrective acti<strong>on</strong>s:-the cable c<strong>on</strong>necting the camera c<strong>on</strong>troller board and the motor power supplyboard is unplugged, damaged or missing- the motor power supply is not c<strong>on</strong>figured properly- there is a fault in the motor power supply board- the cable c<strong>on</strong>necting the mains supply and the motor power supply board is unplugged,damaged or missingcheck all items above20. Check Optima main camera board A/D c<strong>on</strong>verter E368Affected models : Models with optima hardwareService <str<strong>on</strong>g>Codes</str<strong>on</strong>g> : C123Possible causes: - there is a fault in the camera c<strong>on</strong>troller boardCorrective acti<strong>on</strong>s:- check the camera c<strong>on</strong>troller board21. Check Optima main shaft encoder zero mark E369Affected models : Models with optima hardwareService <str<strong>on</strong>g>Codes</str<strong>on</strong>g> : C123Possible causes: - there is a fault in the camera c<strong>on</strong>troller board- there is a fault in the encoder- the cable c<strong>on</strong>necting the camera c<strong>on</strong>troller board and the encoder board is unplugged,missing or damagedCorrective acti<strong>on</strong>s:-check the camera c<strong>on</strong>troller board- check the encoder- check the c<strong>on</strong>necti<strong>on</strong>s22.1. Check Optima inner CCD signals E370Affected models : Models with optima hardwareService <str<strong>on</strong>g>Codes</str<strong>on</strong>g> : C123Possible causes: -the flat cable c<strong>on</strong>necting the camera c<strong>on</strong>troller board and the inner scanner CCDboard is unplugged, missing or damaged- there is a fault in the inner scanner CCD board- there is a fault in the camera c<strong>on</strong>troller boardCopyright © 2007 <str<strong>on</strong>g>Snap</str<strong>on</strong>g>-<strong>on</strong> <strong>Equipment</strong> Services. All Rights Reserved 5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!