23.7 Check Optima outer motor missing steps E386Affected models : Models with optima hardwareService <str<strong>on</strong>g>Codes</str<strong>on</strong>g> : C123Possible causes: - the outer scanner movement is not smooth or it is striking the frame- the motor power supply is not c<strong>on</strong>figured properly- there is a fault in the motor power supply board§ there is a fault in the outer scannermotor- there is a fault in the camera c<strong>on</strong>troller board motor drivers- the cable c<strong>on</strong>necting the camera c<strong>on</strong>troller board and the outer scanner motor ispartially unplugged or damagedCorrective acti<strong>on</strong>s:- check all items above23.8 Check Optima outer laser power supply E387Affected models : Models with optima hardwareService <str<strong>on</strong>g>Codes</str<strong>on</strong>g> : C123Possible causes: -the flat cable c<strong>on</strong>necting the camera c<strong>on</strong>troller board and the outer scanner CCDboard is unplugged, missing or damaged- the cable of the laser module of the outer scanner is damaged or there is a faultin the laser module itself- there is a fault in the camera c<strong>on</strong>troller board laser driversCorrective acti<strong>on</strong>s:- check all items above23.9 Check Optima outer laser modulati<strong>on</strong> E388Affected models : Models with optima hardwareService <str<strong>on</strong>g>Codes</str<strong>on</strong>g> : C123Possible causes: -the flat cable c<strong>on</strong>necting the camera c<strong>on</strong>troller board and the outer scanner CCDboard is unplugged, missing or damaged- the cable of the laser module of the outer scanner is damaged or there is a faultin the laser module itself- there is a fault in the camera c<strong>on</strong>troller board laser driversCorrective acti<strong>on</strong>s:- check all items above24.1 Check Optima rear CCD signals E390Affected models : Models with optima hardwareService <str<strong>on</strong>g>Codes</str<strong>on</strong>g> : C123Possible causes: -the flat cable c<strong>on</strong>necting the camera c<strong>on</strong>troller board and the rear scanner CCDboard is unplugged, missing or damaged- there is a fault in the rear scanner CCD board- there is a fault in the camera c<strong>on</strong>troller board- the supply voltage is c<strong>on</strong>figured too high <strong>on</strong> the power interface boardCorrective acti<strong>on</strong>s:- check all items above§ switch power off and <strong>on</strong> again; should the problem notgo away please call service24.2 Check Optima rear scanner memory E391Affected models : Models with optima hardwareService <str<strong>on</strong>g>Codes</str<strong>on</strong>g> : C123Possible causes: -the flat cable c<strong>on</strong>necting the camera c<strong>on</strong>troller board and the rear scanner CCDboard is unplugged, missing or damaged- there is a fault in the rear scanner CCD board- there is a fault in the camera c<strong>on</strong>troller boardCopyright © 2007 <str<strong>on</strong>g>Snap</str<strong>on</strong>g>-<strong>on</strong> <strong>Equipment</strong> Services. All Rights Reserved 9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!