(2) Outdoor unitModels SCM40ZG-S, 45ZG-SModelsSCM40ZG-SSCM45ZG-SItemCooling capacity W 4000 (1900 ~ 5000) 4500 (1000 ~ 6400)Heating capacity W 5000 (2200 ~ 5200) 5600 (1800 ~ 6800)Power sourcePower consumptionRunning currentNoise levelExterior dimensionsHeight × Width × DepthColor1 Phase 220/230/240V 50HzCooling970 (470 ~ 1430) 1190 (190 ~ 2220)WHeating 1150 (400 ~ 1410) 1350 (220 ~ 1940)Cooling 4.5/4.3/4.1 5.5/5.2/5.0AHeating5.3/5.1/4.8 6.2/5.9/5.7Sound level Cooling : 45 Heating : 47 Cooling : 45 Heating : 47dBPower levelCooling : 60 Heating : 62 Cooling : 60 Heating : 62mm 640 × 850 × 290Stucco whiteNet weight kg 44 46Refrigerant equipmentCompressor type & Q’ty[Rotary] × 1 [Scroll] × 1Motor kW 0.7 0.7Starting methodRefrigerant controlDirect startCapillary tubes + Electric expansion valveRefrigerant kg R410A 1.4 (Pre-charged up to the piping length of 30m) R410A 1.6 (Pre-charged up to the piping length of 20m)Refrigerant oil R 0.32 (RB68A) 0.48 (RB68A)Air handling equipmentFan type & Q’tyPropeller fan × 1Motor W 34Air flow (at high) CMM 40Shock & vibration absorberSafety equipmentRubber (for compressor)Compressor overheat protection, Overcurrent protectionSerial signal error protectionRefrigerantpipingLiquid line: φ 6.35 (1/4″) × 2Size × Core × Number mm (in)Gas line: φ 9.52 (3/8″) × 2Connecting methodFlare connectingAttached length piping —InsulationPower source supplyNecessary (Both Liquid & Gas lines)Terminal block (Screw fixing type)ConnectionwiringSize × Core number 1.5 mm 2 × 4 cores (Including earth cable) × 2Connecting methodTerminal block (Screw fixing type)Accessories (included)Installation sheet, Manual instructionSKM20, 22, 25, 28, 35 type,Indoor units to be combined STM25, 35 type,SRRM25, 35 typeNotes (1) The data are measured at the following conditions.Item Indoor air temperature Outdoor air temperatureOperation DB WB DB WBStandardsCooling 27°C 19°C 35°C 24°C ISO-T1, JIS C9612Heating 20°C – 7°C 6°C ISO-T1, JIS C9612(2) The values for capacity and power consumption shown in a range ( ) indicate the minimum and maximum of the range.(3) The refrigerant quantity to be charged includes the refrigerant in 30 m connecting piping. (SCM40ZG-S)(4) If the piping length exceeds 20 m, additional charging is required. (20g/m, SCM45ZG-S)- 7 -

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!