12.07.2015 Views

Trihal cast resin dry type transformers (ENG) - Trinet

Trihal cast resin dry type transformers (ENG) - Trinet

Trihal cast resin dry type transformers (ENG) - Trinet

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

HV/LV distribution <strong>transformers</strong><strong>Trihal</strong> <strong>cast</strong> <strong>resin</strong> <strong>transformers</strong>T thermal protection modulewith PT 100 sensorsT digital thermometer - technical dataconformity with standards IMQ - VDE - UL - CEEmonitoring circuits supply voltage (1) 24 V to 220 V AC/DCfrequency50-60 Hz AC/DCpower consumption10 VA AC/DC (40 VA pick up)output contacts: maximum switching voltage 250 V ACalarm 1 and alarm 2 maximum switching current 5 A (resistive circuit)rated continuous /service current2 A at 220 V AC/DCrecommended upstream fuse rating 3 Acontact life mechanical 2 x 10 7 operationselectrical 5 x 10 5 h/85°CT digital thermometer(1) universal supply irrespective of polarity.terminal blockmounted onthe transformer4-20 mAoutputtransformercolumnsoperating conditionsadmissible ambienttemperature rangemax. ambient humiditydimensions(H x L x P)weightcasing protection indexmaximum capacityon a terminal connectionfixingPT100 sensors mountedon the transformerACH11 2 3 4 5 6 7 8 913 14 15 16 17 18 19 20 21 22 23 2470 71 72 73S.N. /DATE1 2 3 4BCH2CCH3T - 935POWER24-220 VAC / DCCH45 6 7 8 9 10 1150 51424140ALL 1 ALL 2 FAULT FAN 1sensorfaultmonitorprimaryventilationDue to the evolution of standards and materials, the presentdocument is only binding subject to confirmation by ourtechnical department.whiteredred– 20° C to + 60° C90% RH (non condensable)96 x 96 x 130 mm520 gIP 54 self extinguishing2.5 mm 2locating recess 92 x 92 mm,suppliance of two pressure clipson the rear side.OPTIONSnot includedin the standard“France Transfo” offerFAN 2secondaryventilation(external tothe transformer)24-220 VAC/DCpower supplypower supplyMonitoring circuits have to be supplied from anauxiliary supply (standard: 24 to 220 V AC/DC).If no suitable supply is available they may besupplied from the transformer’s secondaryside. To avoid the “FAULT” relay tripping, it isfitted with a time delay.Warning: when the device is supplied directlyfrom the transformer’s secondary side, it isnecessary to protect it from possible overvoltagesthat could damage the electroniccircuit. We recommend to use our surge-limiterPT 73-120 or PT 73-220 (220 V CA).installationThe T thermometer should never be installedon the transformer or inside its metalenclosure due to its operating temperaturelimits (see table opposite). it can be installed in the low voltage switchboard(or on a wall) either horizontally or vertically(see table opposite for fixing details). it is recommended, especially for an installationin an LV switchboard, to retain a minimumclearance to other equipment (take intoaccount the highest voltage) or heat sourcesand ensure adequate ventilation. Take carealso to the highest voltage according to theinsulation distances. connections:PT 100 sensors are to be connected to the Tdigital thermometer between the connectingterminal attached to the transformer and the Tdigital thermometer’s plug-in connector.It is not supplied by France Transfo.See diagram opposite.Warning: since the transformer is of thermalclass F, the T digital thermometer must beprogrammed with a maximum temperature of150 °C for alarm 1 (L1) and 160 °C for alarm 2(L2). France Transfo is in no way liable for anydamage to the transformer should thesemaximum temperatures not be complied with.The following conditions must be compliedwith- use screened and braided cables(20 twists/meter)- minimum conductor cross-section: 1 mm 2- wiring should not pass near power circuits- maximum length of connection: 300 m- minimum clearances to live parts: see above.- wiring should not be attached to any live partof the transformer- the LV panel should be earthed.insulationminimum clearance(kV)(mm)7,2 27012 45017,5 45024 45036 650advised by France Transfoconnection diagramfor the T digital thermometerFrance TransfoBP 10140F 57281 Maizières-lès-Metz Cedextel. (+33) 03 87 70 57 57 - fax (+33) 03 87 51 10 16Ref : GEa.106 bN° ident. TVA : FR 78 357801109 • Edition France Transfo – Limited company - Social capital 10 280 000 FRF – RCS Metz B 357 801 109 • Printed in France • Composition and illustrations: COREDIT • 10/96

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!