Trihal cast resin dry type transformers (ENG) - Trinet
Trihal cast resin dry type transformers (ENG) - Trinet
Trihal cast resin dry type transformers (ENG) - Trinet
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
HV/LV distribution <strong>transformers</strong>TRIHAL <strong>cast</strong> <strong>resin</strong> <strong>transformers</strong>160 to 3150 kVAinsulation level 24 kV - low voltage 400 VISO 9001AFAQ N 1990/113bdescriptionThis range comprises <strong>transformers</strong> in accordancewith the following specifications: 50 Hz three-phase <strong>transformers</strong> for indoorinstallation (outdoor installation or otherfrequency on request); <strong>cast</strong> <strong>resin</strong> <strong>dry</strong> <strong>type</strong>; thermal class F; ambient 40°C, altitude 1000m (1) ; natural air cooling <strong>type</strong> AN; LV winding usually made of aluminium sheet(insulated strip for low ratings). The core and LVwindings assembly is given an additionalprotective coating of alkyd <strong>resin</strong>; HV winding manufactured from insulatedround wire or rectangular strip; HV winding is vacuum <strong>cast</strong> in epoxy<strong>resin</strong> (2) efficiently fireproofed with trihydratedalumina;TRIHAL <strong>transformers</strong> can be supplied: without enclosure (IP00).The installer must ensure that access to the livecore and windings is prevented (3) ; with IP31 metal enclosure.It prevents direct contact with live components.standardsThese <strong>transformers</strong> are in accordance withstandards: IEC 76-1 à 76-5; IEC 726 (1982); CENELEC (European Committee for Electrotechnicalstandardization) harmonizationdocuments HD 538-1 S1:1992 and HD 464 S1:1988 / A2: 1991 /A3:1992 concerning <strong>dry</strong> <strong>type</strong><strong>transformers</strong>.standard equipmentTRIHAL without enclosure (IP00): 4 flat bi-directional rollers; 4 lifting holes; haulage holes on the underbase; 2 earthing points; 1 rating plate (on HV side); 1 warning label“electricity danger”; HV voltage variation by off circuit tappinglinks; HV connection bars for connection fromabove;LV pre-drilled terminations on above; 1 routine test certificate and 1 instructionleaflet for installation commissioning andmaintenance;TRIHAL with IP31 metal enclosure: TRIHAL without enclosure (IP00) as above; IP31 integral metal enclosure (except thebottom: IP21): with standard anti corrosion protection; lifting lugs for transformer and enclosureassembly; access to tappings on the HV side byremoving a bolted panel which is fitted withhandles, warning label, rating plate and avisible braid for earthing; blanked off holes provided for fitting RonisELP1 or alternatively Profalux P1 locks on theHV tapping access panel; 2 gland plates, one on the HV and one on theLV side. These may be removed and drilled totake cable glands which are not supplied; 1 flap door in the base on the HV side topermit HV cable entry. Connection made to topof delta bars.optionsThe following fittings can be provide: 1 thermal protection module comprising6 PTC thermostatic sensors (2 per phase)connected to a terminal board with a plug-inconnector and an electronic converter with 2contacts (alarm 1 and alarm 2) suppliedseparately; 3 HV plug-in connectors (HN 52 S 61) maybe used as follows: fixed on a mounting plate from the uppercore clamp (TRIHAL IP00); fixed on top of the transformer enclosure onthe HV side (TRIHAL IP 31); straight or elbow connectors can also besupplied. Please state cable characteristics; additional LV terminal plates (tinned copper); 1 locking device to secure plug-in bushings(without lock and indiscriminitely suitable for aRonis EPL11AP, ELP1, ELP2 or Profalux P1,P2, V1, V21 lock mounting); forced cooling by fans to give an AF ratingof 140%.Nota: These options are those usuallyspecified and many alternatives can beprovided on request.250 kVA (IP00) 20 kV/400 V +400 kVA (IP31) 20 kV/400 VLV pre-drilled terminations630 kVA - 20 kV/400 V(1) Please state when ambient > 40°C or altitude > 1000 m.(2) a <strong>cast</strong>ing system developped and patented by FranceTransfo.(3) when the transformer is energized, the winding <strong>resin</strong> coatingand the heat shrinkable protection of the HV connectionbars do not ensure any protection against touch.