TALEXXconverter LCI 60 W 700/1050 mA TEC SR - Tridonic
TALEXXconverter LCI 60 W 700/1050 mA TEC SR - Tridonic
TALEXXconverter LCI 60 W 700/1050 mA TEC SR - Tridonic
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
LED control gearCompact fixed outputSpecific technical dataTypeOutputcurrentPowerfactor at fullload 1Efficiencyat fullload 1Power Efficiencyfactor at at min.min. load 1 load 1Min. outputvoltage 1Max. outputvoltage 1Max. outputvoltage (noloadvoltage)Max. repetitiveoutput peakcurrent at fullload 12Max. repetitiveoutput peakcurrent at min.load 12Max. nonrepetitiveoutputpeak current atfull load 12Max. nonrepetitiveoutputpeak current atmin. load 12Max. casingtemperature tc<strong>LCI</strong> <strong>60</strong>W <strong>700</strong><strong>mA</strong> <strong>TEC</strong> <strong>SR</strong> <strong>700</strong> <strong>mA</strong> 0.98 91.5 % 0.93C 90 % 46.5 V 85.5 V 92 V 950 <strong>mA</strong> 1,100 <strong>mA</strong> 1,050 <strong>mA</strong> 1,150 <strong>mA</strong> 80 °C<strong>LCI</strong> <strong>60</strong>W <strong>1050</strong><strong>mA</strong> <strong>TEC</strong> <strong>SR</strong> 1,050 <strong>mA</strong> 0.98 90.5 % 0.93C 89 % 31.0 V 57.0 V 62 V 1,420 <strong>mA</strong> 1,640 <strong>mA</strong> 1,420 <strong>mA</strong> 1,650 <strong>mA</strong> 85 °C1Test result at 230 V, 50 Hz.2The trend between min. and full load is linear.Data sheet 01/15-LC036-7Subject to change without notice.www.tridonic.com 2