LED control gearCompact fixed outputUconverter <strong>LCI</strong> <strong>60</strong> W <strong>700</strong>/<strong>1050</strong> <strong>mA</strong> <strong>TEC</strong> <strong>SR</strong><strong>TEC</strong> seriesProduct description• Independent fixed output LED control gear• Constant current LED control gear• Output current <strong>700</strong> or 1,050 <strong>mA</strong>• Max. output power <strong>60</strong> W• Nominal life-time up to 50,000 h• For luminaires of protection class I and protection class II• For luminaires with M and MM as per EN <strong>60</strong>598, VDE 0710 andVDE 0711• Temperature protection as per EN 61347-2-13 C5e• 5-year guaranteeProperties• Casing: polycarbonat, white• Type of protection IP20159,434Functions• Overtemperature protection37Ø 86• Overload protection• Short-circuit protectiontc313382• No-load protection125,5Technical dataRated supply voltage220 – 240 VInput voltage, AC198 – 264 VCurrent at 50 Hz 230 V0.29 AMains frequency50 / <strong>60</strong> HzOvervoltage protection300 V AC, 1 hMax. input power70 WOutput power<strong>60</strong> WTHD (at 230 V, 50 Hz, full load) < 20 %Output current tolerance ± 7.5 %Typical ripple current at full load ± 25 %Turn on time (at 230 V, 50 Hz, full load) ≤ 0.7 sTurn off time (at 230 V, 50 Hz, full load) ≤ 0.7 sHold on time at power failure0 sAmbient temperature ta -20 ... +50 °CAmbient temperature ta (at life-time 50,000 h) 40 °CStorage temperature ts -40 ... +80 °CDimensions L x W x H159.4 x 82 x 34 mmOrdering dataTypeArticlenumberPackaging,cartonPackaging,low volumePackaging,high volumeWeight perpc.<strong>LCI</strong> <strong>60</strong>W <strong>700</strong><strong>mA</strong> <strong>TEC</strong> <strong>SR</strong> 87500201 20 pc(s). 280 pc(s). 1,120 pc(s). 0.220 kg<strong>LCI</strong> <strong>60</strong>W <strong>1050</strong><strong>mA</strong> <strong>TEC</strong> <strong>SR</strong> 87500203 20 pc(s). 280 pc(s). 1,120 pc(s). 0.228 kgÈStandards, page 3Wiring diagrams and installation examples, page 4Data sheet 01/15-LC036-7Subject to change without notice.www.tridonic.com 1


LED control gearCompact fixed outputSpecific technical dataTypeOutputcurrentPowerfactor at fullload 1Efficiencyat fullload 1Power Efficiencyfactor at at min.min. load 1 load 1Min. outputvoltage 1Max. outputvoltage 1Max. outputvoltage (noloadvoltage)Max. repetitiveoutput peakcurrent at fullload 12Max. repetitiveoutput peakcurrent at min.load 12Max. nonrepetitiveoutputpeak current atfull load 12Max. nonrepetitiveoutputpeak current atmin. load 12Max. casingtemperature tc<strong>LCI</strong> <strong>60</strong>W <strong>700</strong><strong>mA</strong> <strong>TEC</strong> <strong>SR</strong> <strong>700</strong> <strong>mA</strong> 0.98 91.5 % 0.93C 90 % 46.5 V 85.5 V 92 V 950 <strong>mA</strong> 1,100 <strong>mA</strong> 1,050 <strong>mA</strong> 1,150 <strong>mA</strong> 80 °C<strong>LCI</strong> <strong>60</strong>W <strong>1050</strong><strong>mA</strong> <strong>TEC</strong> <strong>SR</strong> 1,050 <strong>mA</strong> 0.98 90.5 % 0.93C 89 % 31.0 V 57.0 V 62 V 1,420 <strong>mA</strong> 1,640 <strong>mA</strong> 1,420 <strong>mA</strong> 1,650 <strong>mA</strong> 85 °C1Test result at 230 V, 50 Hz.2The trend between min. and full load is linear.Data sheet 01/15-LC036-7Subject to change without notice.www.tridonic.com 2


LED control gearCompact fixed outputStandardsEN 55015EN <strong>60</strong>598-1EN 61000-3-2EN 61000-3-3EN 61347-1EN 61347-2-13EN 61547EN 62384Overload protectionIf the output voltage range is exceeded the LED control gear reduces the LEDoutput current. After elimination of the overload the nominal operation isrestored automatically.Overtemperature protectionThe LED control gear is protected against temporary thermal overheating. If thetemperature limit is exceeded the output current is reduced to limit tc at acertain level. It restarts automatically. The temperature protection is activatedtypically at 8 °C above tc max.Short-circuit behaviourIn case of a short circuit on the secondary side (LED) the LED control gear switchesinto hic-cup mode. After elimination of the short circuit the nominal operation isrestored automatically.No-load operationThe LED control gear works in constant voltage mode. In no-load operation theoutput voltage will not exceed the specified max. output voltage (see page 2).Installation instructionsThe LED module and all contact points within the wiring must be sufficientlyinsulated against 5.0 kV surge voltage.Air and creepage distance must be maintained.Fixing conditionsDry, acidfree, oilfree, fatfree. It is not allowed to exceed the maximum ambienttemperature (ta) stated on the device. Minimum distances stated below arerecommendations and depend on the actual luminaire. Is not suitable for fixingin corner.LeuchteLuminaire>100 mm>20 mmStorage conditionsHumidity: 5 % up to max. 85 %not condensed(max. 56 days/year at 85 %)Storage temperature: -40 °C up to max. +80 °C>50 mmThe devices have to be within the specified temperature range (ta) before theycan be operated.Replace LED module1. Mains off2. Remove LED module3. Wait for 10 seconds4. Connect LED module againHot plug-in or secondary switching of LEDs is not permitted and may cause avery high current to the LEDs.Expected life-timeType ta 40 °C 50 °C <strong>60</strong> °C<strong>LCI</strong> <strong>60</strong>W <strong>700</strong><strong>mA</strong> <strong>TEC</strong> <strong>SR</strong>tc 70 °C 80 °C xLife-time 50,000 h 30,000 h x<strong>LCI</strong> <strong>60</strong>W <strong>1050</strong><strong>mA</strong> <strong>TEC</strong> <strong>SR</strong>tc 75 °C 85 °C xLife-time 50,000 h 30,000 h xThe LED Drivers are designed for a life-time stated above under referenceconditions and with a failure probability of less than 10 %.Maximum loading of automatic circuit breakersAutomatic circuitC10 C13 C16 C20 B10 B13 B16 B20 Inrush currentbreaker typeInstallation Ø 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 1.5 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 Imax Time<strong>LCI</strong> <strong>60</strong>W <strong>700</strong><strong>mA</strong> <strong>TEC</strong> <strong>SR</strong> 20 30 40 50 16 24 32 40 13 A 50 µs<strong>LCI</strong> <strong>60</strong>W <strong>1050</strong><strong>mA</strong> <strong>TEC</strong> <strong>SR</strong> 20 30 40 50 16 24 32 40 13 A 50 µsHarmonic distortion in the mains supply (at 230 V / 50 Hz and full load) in %THD 3. 5. 7. 9. 11.<strong>LCI</strong> <strong>60</strong>W <strong>700</strong><strong>mA</strong> <strong>TEC</strong> <strong>SR</strong> 20 7 3 2 1 1<strong>LCI</strong> <strong>60</strong>W <strong>1050</strong><strong>mA</strong> <strong>TEC</strong> <strong>SR</strong> 20 5 2 1 1 1Data sheet 01/15-LC036-7Subject to change without notice.www.tridonic.com 3


LED control gearCompact fixed outputWiring diagram220–240 V50/<strong>60</strong> HzLN+ + LED– – LEDUmoduleUconverter<strong>LCI</strong> ... <strong>TEC</strong> <strong>SR</strong>Glow wire testaccording to EN <strong>60</strong>598-1 with increased temperature of 9<strong>60</strong> °C passed.Isolation and electric strength testing of luminairesElectronic devices can be damaged by high voltage. This has to be consideredduring the routine testing of the luminaires in production.NLSECPRIWiring type and cross sectionThe wiring can be in stranded wires with ferrules or solid. For perfect functionof the cage clamp terminals the strip length should be 5 – 7 mm for the inputterminal.The max. torque at the clamping screw (M3) is 0.2 Nm.Input / Output terminalmax. ∅ = 10,0 mmmin. ∅ = 2,2 mm0,5 – 2,55 – 7Wiring instructions• All connections must be kept as short as possible to ensure good EMIbehaviour• Mains leads should be kept apart from LED control gear and other leads(ideally 5 – 10 cm distance)• The maximum length of output wires is 2 m.• Secondary switching is not permitted.• Incorrect wiring can damage LED modules.• The wiring must be protected against short circuits to earth (sharp edged metalsparts, metal cable clips, louver, etc.)According to IEC <strong>60</strong>598-1 Annex Q (informative only!) or ENEC 303-Annex A, eachluminaire should be submitted to an isolation test with 500 V DC for 1 second. Thistest voltage should be connected between the interconnected phase and neutralterminals and the earth terminal.The isolation resistance must be at least 2 MΩ.As an alternative, IEC <strong>60</strong>598-1 Annex Q describes a test of the electrical strengthwith 1500 V AC (or 1.414 x 1500 V DC). To avoid damage to the electronic devices thistest must not be conducted.Additional informationAdditional technical information atwww.tridonic.com → Technical DataGuarantee conditions atwww.tridonic.com → ServicesNo warranty if device was opened.Data sheet 01/15-LC036-7Subject to change without notice.www.tridonic.com 4


LED control gearCompact fixed outputDiagrams <strong>LCI</strong> <strong>60</strong>W <strong>700</strong><strong>mA</strong> <strong>TEC</strong> <strong>SR</strong>Efficiency vs loadPower factor vs loadEfficiency [%]9290888684828050 <strong>60</strong> 70 80 90 100Load [%]Power factor1,000,980,9<strong>60</strong>,940,920,900,880,8<strong>60</strong>,840,820,8050 <strong>60</strong> 70 80 90 100Load [%]THD vs load2015THD [%]<strong>1050</strong>50 <strong>60</strong> 70 80 90 100Load [%]Data sheet 01/15-LC036-7Subject to change without notice.www.tridonic.com 5


LED control gearCompact fixed outputDiagrams <strong>LCI</strong> <strong>60</strong>W 1,050<strong>mA</strong> <strong>TEC</strong> <strong>SR</strong>Efficiency vs loadPower factor vs loadEfficiency [%]9290888684828055 <strong>60</strong> 65 70 75 80 85 90 95 100Load [%]Power factor1,000,980,9<strong>60</strong>,940,920,900,880,8<strong>60</strong>,840,820,8055 <strong>60</strong> 65 70 75 80 85 90 95 100Load [%]THD vs load20THD [%]15<strong>1050</strong>55 <strong>60</strong> 65 70 75 80 85 90 95 100Load [%]Data sheet 01/15-LC036-7Subject to change without notice.www.tridonic.com 6