ISOLATED POWER CENTERS - Bender

ISOLATED POWER CENTERS - Bender

ISOLATED POWER CENTERS - Bender

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

IntroductionISOTROL SYSTEMS Type IPC Isolated Power Centers havebeen designed to provide isolated power to electrical circuitsinstalled within operating rooms and other electricallysusceptible patient care areas. Designed in strict compliancewith Underwriters Laboratories Standards UL1047, UL1022and UL50, the IPC offers the most current technology for allisolated power distribution requirements.GeneralThe Type IPC typically includes a single phase transformer, aBENDER Line Isolation Monitor (LIM), a reference ground bus,a primary circuit breaker, branch circuit breakers, HospitalGrade power receptacles and Hospital Grade ground jacks.The maximum number of branch circuit breakers is limited tosixteen (16) plug-on or twelve (12) bolt-on.BackboxAll backboxes are fabricated from 14GA galvanized steel.Surface mounted enclosures are finished with a coat ofhospital ivory, epoxy enamel. Outline drawings shown on thefollowing pages of this brochure provide additional dimensionaland construction details.Front TrimManufactured from 14GA Type 304 Stainless Steel with a #4brushed finish, the front trim contains a door with hiddenhinges and a flush mounted key lock that covers the loadcenter. The front trim for flush mounted units extends 1" on allsides of the backbox. For surface mounted units, the front trimshall exactly match the dimensions of the backbox.Isolation TransformerIsolation transformers are available with various primary andsecondary single phase voltages. The transformer ratings aregiven on the isolation transformer data sheet found in ISOTROL'sfull catalog or by request.Line Isolation Monitor (LIM)The BENDER LIM2000plus TM series Line Isolation Monitorprovides a digital / analog display. The LIM is available in singleor three phase models with readout and response values of2 or 5mA. The LIM2000plus TM has a patented measuringprinciple and is capable of detecting all combinations ofcapacitive and resistive faults, including balanced, unbalancedand hybrid faults. A self-test and calibration function is alsofeatured. The LIM2000plus TM series LIM contributes less than35µA to the Total Hazard Current (THC). Available optionsinclude load monitoring and RS485 communication. Forfurther information see the LIM2000plus TM series data sheet.Line Isolation MonitorLIM2000plus TMLoadcenterThe loadcenter is an integral part of the IPC. Included is aprimary circuit breaker which provides protection for theisolation transformer. All Isolated Power Centers canaccommodate either plug-on or bolt-on circuit breakers.Power Receptacles & Ground JacksThe Type IPC provides an eight gang section for HospitalGrade power receptacles and Hospital Grade ground jacks.The Hospital Grade power receptacles are available in eitherstraight-blade (single or duplex) or twist-to-lock style. Eachgang can accommodate one duplex or single power receptacleand one ground jack or two ground jacks.Reference Ground BusThe Type IPC Isolated Power Center is provided with a twenty(20) point reference ground bus to satisfy equipotentialgrounding requirements and for connection to master groundmodules and ground jacks in patient ground modules andreceptacle ground modules. Other ground bus configurationsavailable.Support and ServicesOn-site installation inspection and certification servicesSystem design assistance provided upon requestTechnical support hotline: (800) 833-6834IPC - 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!