University of California at RiversideSite Evaluation SurveyReport: UCR P5482 <strong>Boyden</strong> <strong>Lab</strong> in Riverside, CA900 University Avenue39. Clear Space at Doors - Room #109D on the 1st Floor.Memo:Areas noted in compliance:Floor or landing is level and clear (2% max. slope).60” min. clear space in direction of door swing.44” min. clear space opposite direction of door swing (48” with latch and closer).Minimum strike side clearance on PUSH side of door: 12” front approach with latch and closer.Areas not meeting new construction standards:Minimum strike side clearance on PULL side of door: 18” interior doors, front approach. (0” to freezer.)Recommendation:Relocate furniture to provide clear space.Photo #UCR P5482 <strong>Boyden</strong> <strong>Lab</strong>-39-1 (originally 0559-400)64