12.07.2015 Views

Boyden Lab

Boyden Lab

Boyden Lab

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Report #UCR P5482 <strong>Boyden</strong> <strong>Lab</strong>ReportNameItem/LocationBarrier(noted feature, item or area does not meet thenew construction criteria detailed below)Action Priority TargetDateEstimatedCostInterimSolutionActionCompletionDateUCR P5482 1-Pedestrian Ramps:<strong>Boyden</strong> <strong>Lab</strong> West Entrance on the1st Floor. [10' ramp.]UCR P5482 2-Ramp Handrails: West<strong>Boyden</strong> <strong>Lab</strong> Entrance on the 1stFloor.8.33% maximum surface slope at ramp. 60" x60" min. top landing. NOTE: When a ramp leadsdirectly to a door that swings out into the toplanding area the top landing must measure aminimum 42"+ the door width. 2% maximumslope in any direction at bottom landing.Handrails are provided on both sides.Handrails are on both sides and continuous thefull length of the ramp.Replace pedestrian ramp.Replace bottom landing forramp. Extend the top landingarea. See Sequence #2 foradditional actions.Install free-standing handrails.Provide bottom railing for dropoffat ramp.2 $4,655.462 $9,370.94UCR P5482 3-Doors: West Entrance<strong>Boyden</strong> <strong>Lab</strong> on the 1st Floor. [Oneset of double doors.]1/4" maximum vertical threshold or 1/2" beveledat 1:2. 32" minimum clear width of doorway. 5 lb.maximum pressure to operate exterior doors.Door hardware is operable with a single effort(lever type, panic bar or push pull type). Bottom10" of door (except automatic or sliding doors)has a smooth uninterrupted surface that allowsdoor to be opened by a wheelchair footrestwithout creating a trap or hazardous condition(kick plate). The international symbol ofaccessibility is posted at all primary entrances.Replace or modify thethreshold. Replace doorhardware with complianthardware. Install automaticdoor opening device. Post asign/decal displaying the"International Symbol ofAccessibility" at the primaryentrance.1 $7,236.72UCR P5482 4-Clear Space at Doors:<strong>Boyden</strong> <strong>Lab</strong> West Entrance on the1st Floor. [One set ofdouble doors.]UCR P5482 5-Signage: West<strong>Boyden</strong> <strong>Lab</strong> Entrance on the 1stFloor.60" min. clear space in direction of door swing.44" min. clear space opposite direction of doorswing (48" with latch and closer).Permanent I.D. signs, when provided, areinstalled on the wall adjacent to the latch side ofthe door NOTE: At double leaf doors, and whenthere is no room on the latch side, signs shall beplaced on the nearest adjacent wall, preferablyon the right.Relocate furniture to provideclear space. University staffshall be instructed to place andmaintain the placement offurniture to provide a clear pathof travel and avoid theobstruction of accessiblerequired clear spaces. SeeSequence #1 forrecommendations. Relocatetanks to provide clear space.Install permanent ID sign tolatch side of door.1M $245.011 $183.756/1/2012 Page 1 of 18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!