Main<strong>switchSurfacemounting</strong><strong>Partno</strong>.<strong>T0</strong>-2-<strong>8900</strong>/<strong>I1</strong>/<strong>SVB</strong>Articleno. 207151CatalogNo.C<strong>T0</strong>2-<strong>8900</strong>-<strong>I1</strong>CRQIP65DeliveryprogrammeProduct range Switch-disconnectorsBasic function Main switchesMaintenance switchesManual override switchesPart group reference <strong>T0</strong>Design Surface mountingProtection type IP65Emergency stop As an emergency switching off/emergency stop deviceWith red rotary handle and yellow locking ringStandards According to IEC/EN 60204-1, VDE 0113 Part 1Locking facility Lockable in the 0 (Off) positionwithout auxiliary contactsContacts Neutral poleContact sequenceFront plate no.Main conducting pathsNo. of poles M 3 + NAuxiliary contactsN/O 0B 0Max. motor ratingAC-23A04/23/2013 HPL-ED2013 V1.0 EN 1 / 6


400/415 V50-60 HzP kW 6.5Rated uninterrupted current I u A 20GeneralStandards IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, ULSwitch-disconnectors to IEC/EN 60947-3Load-break switches to IEC/EN 60947-3Lifespan, mechanical Operations x10 6 0.4Maximum operating frequency Operations/ 3000hClimatic proofing Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC60068-2-30Ambient temperature °COpen °C - 25 - 50Enclosed °C - 25 - 40Mounting position As requiredMechanical shock resistance to IEC 60068-2-27ContactsHalfsinusoidalshock 20msRated operational voltage U e VACg > 15690Rated impulse withstand voltage U imp VAC6000Overvoltage category/pollution degree III/3Rated uninterrupted current I u Aopen I u A 20Enclosed I u A 20Load rating with intermittent operation, class 12AB 25 % DF x I e 2AB 40 % DF x I e 1.6AB 60 % DF x I e 1.3Short-circuit ratingFuse AgG/gL20Rated short-time withstand current (1 s current) I cw A rms 320Safe isolation to EN 61140between the contacts VAC440Switching angles ° 90604530Contact units 11Double-break contacts max. 22Current heat loss per contact at I e W 0.6TerminalcapacitiesSolid or stranded 2mm 1 x (1 - 2.5)2 x (1 - 2.5)Flexible with ferrules to DIN 46228 mm 2Flexible with ferrule 2mm 1 x (0.75 - 1.5)2 x (0.75 - 1.5)Terminal screw M3.5Tightening torque Nm 1SwitchingcapacityAC x U sRated making capacity cos ϕ = 0.35 A 130Rated breaking capacity, motor load switch cos ϕ = 0.35 A230 V A 10004/23/2013 HPL-ED2013 V1.0 EN 2 / 6


400 V A 110500 V A 80690 V A 60Rated operational current 440 V load-break switch AC-21A I e A 20Rating, AC-3 motor load switch P kW220 V 230 V P kW 3230 V Star-delta P kW 4380 V 400 V P kW 4400 V Star-delta P kW 5.5500 V P kW 5.5500 V Star-delta P kW 7.5660 V 690 V P kW 4690 V Star-delta P kW 5.5AC-23A Motor load switches (main switches maintenance switches) P kW230 V P kW 3.5400 V P kW 6.5500 V P kW 7.5Rated operational current control switch AC-15220 V 230 V 240 V I e A 6380 V 400 V 415 V I e A 4500 V I e A 2DC x U sDC-1, Load-break switches L/R = 1 msRated operational current I e A 10Voltage per contact pair in series V 60DC-21A I e ARated operational current 240 V I e A 1240 V Contacts Quantity 1DC-23A, motor load switch L/R = 15 ms24 V48 V60 V120 V240 VRated operational current I e A 10Contacts Quantity 1Rated operational current I e A 10Contacts Quantity 2Rated operational current I e A 10Contacts Quantity 3Rated operational current I e A 5Contacts Quantity 3Rated operational current I e A 5Contacts Quantity 5DC-13, Control switches L/R = 50 msRated operational current I e A 10Voltage per contact pair in series V 32Control circuit reliability at 24 V DC, 10 mAAuxiliarycontactsFaultprobabilityH F< 10-5 , < 1 fault in 100000 operationsStandards According to IEC/EN 60204-1, VDE 0113 Part 1NotesNotesIsolating characteristics as specified in IEC/EN 60947 for rated operating voltage U e of up to 500 VACThe following applies for solid, multiwire, and flexible terminal capacities:If 2 conductors are being used, a max. difference of 2 cross-section categories is permissible04/23/2013 HPL-ED2013 V1.0 EN 3 / 6


TechnicaldataETIM4.0Version as switch disconnector compact NoVersion as main switch YesVersion as maintenance-/service switch YesVersion as safety switch NoVersion as emergency stop installation YesMax. rated operation voltage Ue AC V 690Rated permanent current Iu A 20Rated operation power AC-3, 400 V kW 4Rated operation power at AC-23, 400V kW 6,5Conditioned rated short-circuit current Iq kA 0Number of poles 4Number of auxiliary contacts as normally closed contact 0Number of auxiliary contacts as normally open contact 0Number of auxiliary contacts as change-over contact 0Motor drive optional NoMotor drive integrated NoVoltage release optional NoDevice construction Complete device in housingSuitable for ground mounting YesSuitable for front mounting NoSuitable for front mounting center NoSuitable for distribution board installation NoSuitable for intermediate mounting NoType of control element -Interlockable YesConnection type main current circuit Screw connectionDegree of protection (IP), front side IP65CharacteristicsFor utilisation category AC-4 (extreme load: 100 % inching, reversing or plugging)The blocked rotor current of the motor should not exceed the rated current of the switch for AC-21A to ensure a reasonable device lifespan.Dimensions04/23/2013 HPL-ED2013 V1.0 EN 4 / 6


Depth of one contact unit: 9.5 mm04/23/2013 HPL-ED2013 V1.0 EN 5 / 6


Diameter of drilled hole Bottom3 PadlocksAdditionalproductinformation(links)IL03801007Z(AWA1150-1687)Camswitch:SurfacemountingenclosureIL03801007Z (AWA1150-1687) Camswitch: Surface mounting enclosureftp://ftp.moeller.net/DOCUMENTATION/AWA_INSTRUCTIONS/IL03801007Z2013_02.pdfhttp://ecat.moeller.net/flip-cat/?edition=HPLEN&startpage=4.8704/23/2013 Eaton Industries GmbHhttp://www.eaton.eu© 04/2013 by Eaton Industries GmbHHPL-ED2013 V1.0 EN6 / 6