22 Sensitivity<br />
Depth<br />
23<br />
Sensitivity is the detector’s level of<br />
response to its environment and to<br />
targets. Sensitivity can be only be<br />
adjusted in Smartfind and Digital Display.<br />
The Sensitivity bar is a visual indication of<br />
the Sensitivity setting.<br />
Sensitivity can be adjusted in both the<br />
Semi-automatic mode or Manual mode.<br />
In Semi-Automatic Sensitivity mode,<br />
the detector continuously monitors the<br />
environmental conditions and will adjust<br />
the Sensitivity as close as possible to your<br />
specified level of Sensitivity.<br />
In Manual Sensitivity mode the<br />
adjustment allows you to control the<br />
Sensitivity directly. This is recommended<br />
for high trash areas when best results<br />
are obtained by sweeping the coil very<br />
slowly. Manual Sensitivity is suitable<br />
for the beach and very quiet/stable<br />
(unmineralised) ground, where the<br />
ground conditions do not change as<br />
often.<br />
Modes: Semi-Automatic, Manual<br />
Range: 1 to 32<br />
Factory Preset: Semi-Automatic, 22<br />
Maximum setting (32)<br />
Current Sensitivity level (e.g. 22)<br />
Minimum setting (1).<br />
To adjust Sensitivity:<br />
Press the top-left shift button to increase<br />
Sensitivity.<br />
Press the bottom-left shift button to<br />
decrease Sensitivity.<br />
To switch from Semi-Automatic to<br />
Manual Sensitivity:<br />
Press the center-left shift button. A line will<br />
cycle around the number to indicate that<br />
Semi-Automatic Sensitivity is activated.<br />
The detector with a high Sensitivity setting<br />
will detect deep targets but may respond<br />
to unwanted noise and ground signals. A<br />
high Sensitivity setting is recommended<br />
for stable conditions with low interference.<br />
The detector with a low Sensitivity setting<br />
will ignore unwanted noise and ground<br />
signals, but may miss deep targets. A lower<br />
Sensitivity setting is preferable for very<br />
variable, ‘noisy’ conditions or high trash<br />
areas.<br />
Try reducing interference before<br />
reducing Sensitivity. Press the NOISE<br />
CANCEL shortcut button, or manually<br />
select the least noisy channel (pg. 56).<br />
The clear portion of the depth indicator<br />
represents the approximate distance of<br />
a target below the coil.<br />
The top of the indicator represents the<br />
position of the coil and the bottom<br />
represents 300mm (12 inches) from the<br />
coil. The bar will be clear if the target<br />
is deeper than 12 inches or its depth<br />
cannot be accurately gauged.<br />
Try to think of the clear area of the depth<br />
indicator as the amount of soil you will<br />
you have to dig to recover the target.<br />
The depth indicator is also<br />
updated for rejected targets.<br />
300mm<br />
eg. 120mm