5.2 Digital Inputs (8-10)TM<strong>VeeCAN</strong> <strong>320</strong>This screen is designed for configuration of digital input signals.NOTE: Only pin 10 can be used as a tachometer signal.Signal Type - Select from a digital count, frequency, period or level.Parameter - Used to select the function.Table - Not selectable.Signal Gain and Signal Offset - used to adjust accuracy of the readings.25