12.07.2015 Views

enda euc942 pid universal controller - SURAN Industrieelektronik

enda euc942 pid universal controller - SURAN Industrieelektronik

enda euc942 pid universal controller - SURAN Industrieelektronik

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

TERMSENDAPVEUC 942( 1 ) Process value during normal operationMnemonic parameter code during programming( 2 ) Set point during normal operation.Data value during programming( 7 )CNT/AL2AN/SSRAL1SETCSETASETSVUNIVERSAL CONTROLLER( 3 ) Increment key during normal operation and programmingParameter selection key during programming( 4 ) Decrement key during normal operationIf only this key is pressed in normal operation, software version number is seen.Parameter selection key during programming( 5 ) Alarm set key during normal operationMenu selection key during programming( 6 ) Control set key during normal operationParameter selection key during programming( 1 ) PV display( 2 ) SV displayCharacter heights( 3 ),( 4 ),( 5 ),( 6 ) Keypad( 7 ) State indicator4 digits 7 segment red LED4 digits 7 segment yellow LEDPV display :20 mmSV display :14 mmMicro switchALARM1 AND ALARM2 OUTPUT TYPESIndependent Alarm Deviation AlarmA1.tP. = indE A1.tP. = DE.3 red LEDs for Control, Alarm1 and SSR outputsBand AlarmA1.tP. = bAndSVON SV ON SVONOFF OFF A.StA. = HiOFF A1.St. = boHiON ON ONOFF OFF A.StA. = Lo OFF A1.St. = biHia1.Hy. A1.Hy.. A1.Hy. A1.Hy.ASVSV-ASV SV+ASV( ASV min = beginning of scale -300 SV+ASV +300 300300ASV max = end of scale)(ASV min. =-300, ASV max. = +300)SV = Set point of CONT output ASV = Set point of AL1 output(If inP = Pt..0,ASV min. = -30.0,ASV max. = +30.0)(ASV min. = 0, ASV max. = +300)SV = Set point of CONT output ASV = Set point of alarm output(If inP = Pt..0,ASV min. = 0.0, ASV max. = +30.0)Band Alarm With InhibitionA1.tP. = BAn.i.SV+ASVSVSV-ASVSV+ASVSVSV-ASVONOFFONOFFBeginningof procedureBand alarm is possibleBeginningof procedureBand alarm is possibleSV =Set point of CONT output ASV = Set point of AL1 output (ASV min. = 0, ASV max. = 300 )MODIFICATION OF CONTROL AND ALARM SET POINTS130150PVSVSETCSETC.SEt150PVSVSETCSETC.SEt149PVSVSETCSETC.SEt150PVSVWhen CSET is released, itreturns to normal operation.SETCSETSETFirst, press and hold key until the massageC.Setappears on the display. Then, the value is adjusted by using keys.CSETA1.sE.250PVA1.sE.249SVSVASET ASET ASETPVA1.sE.250PVSVASETWhen ASET is released, itreturns to normal operation.First, press and hold key, alarm setpoint value appears on the display. Then, the value is adjusted by using keys. .ASETIfC.ot.S different fromout1.Alarm1 and Alarm2 setpoint values can be adjusted in sequence when per press key.ASETNOTE: The maximum of C.SEt is the value of C.Hi.L. parameter and the minimum of it is the value ofC.Lo.L.parameter.If independent alarm is selected, A1.SE. andA2.SE.values can be adjusted between the limits of the full scale.If deviation alarm is selected, A1.SE. andA2.SE.values can be adjusted between -300 and + 300.If band alarm is selected, A1.SE. andA2.SE.values can be adjusted between0 and + 300.Error Messages- - - -- - - - PFA150 150 150Temperature value ishigher than the scalePV PV PV PVPSCSV SV SV SVTemperature value islower than the scaleTemperature sensoris broken or over temperature150Pt 100 or a sensorline is short circuited4./5 EUC942-E

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!