12.07.2015 Views

msz-gc35va

msz-gc35va

msz-gc35va

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

NOTE 2FOR MULTI SYSTEM AIR CONDITIONEROUTDOOR UNIT : MXZ seriesMulti system air conditioner can connect two or more indoor units with one outdoor unit.•Unit won’t operate in case the total capacity of indoor units exceeds the capacity of outdoor units. Do not connectindoor units beyond the outdoor unit capacity.Operation indicator lamp flashes as shown in the figure below.•When you try to operate two or more indoor units with one outdoor unit simultaneously, one for the cooling andthe others for heating, the operation mode of the indoor unit that operates earlier is selected. The other indoorunits cannot operate, indicating as shown in the figure below. In this case, please set all the indoor units to thesame operation mode.OPERATION INDICATORLightedBlinkingNot lighted•When indoor unit starts the operation while the defrosting of outdoor unit is being done, it takes a fewminutes(max. 10 minutes) to blow out the warm air.•In the heating operation, though indoor unit that does not operate may get warm or the sound of refrigerantflowng may be heard, they are not malfunction. The reason is that the refrigerant continuously flows into it.9-5. AUTO VANE OPERATION1. Horizontal vane(1) Vane motor driveThese models are equipped with a stepping motor for the horizontal vane. The rotating direction, speed, and angle ofthe motor are controlled by pulse signals (approx. 12V) transmitted from indoor microprocessor.(2) The horizontal vane angle and mode change as follows by pressing VANE CONTROL button.(3) PositioningTo confirm the standard position, the vane moves until it touches the vane stopper. Then the vane is set to the selectedangle.Confirming of standard position is performed in the following cases:(a) When the operation starts or finishes (including timer operation).(b) When the test run starts.(c) When standby mode (only during multi system operation) starts or finishes.(4) VANE AUTO ( ) modeIn VANE AUTO mode, the microprocessor automatically determines the vane angle to make the optimum room temperaturedistribution.In COOL and DRY operationIn HEAT operationHorizontalpositionVane angle is fixed to Horizontal position.Vane angle is fixed to Angle 4.(5) STOP (operation OFF) and ON TIMER standbyIn the following cases, the horizontal vane returns to the closed position.(a) When OPERATE/STOP (ON/OFF) button is pressed (POWER OFF).(b) When the operation is stopped by the emergency operation.(c) When ON TIMER is ON standby.(6) Dew preventionDuring COOL or DRY operation with the vane angle at Angle 2 ~ 4 when the compressor cumulative operation timeexceeds 1 hour, the vane angle automatically changes to Angle 1 for dew prevention.11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!