5. INSTALLATION AND START-UP5.1 General informationa- <strong>SESAME</strong> may get all lots from one bidder.b- The contractor will specify the cables for the connections of the different controlsystem components at an early stage of the contract execution.c- For the setup, the manufacture shall write an installation manual that will bedelivered to <strong>SESAME</strong> at least 6 weeks before the system delivery. This manualshall contain all the important information for the startup procedure. In addition,the contractor shall supply all the special material required for the setup.d- The electrical power installed by <strong>SESAME</strong>. The low voltage fluctuations at<strong>SESAME</strong> are ± 1% of the nominal voltage. Radiation monitors must haveswitched mode power supplies.e- Earth connection labeling is proposed and labeled by the bidder. (See Annex 4 forlabeling examples)5:2 Responsibilities of <strong>SESAME</strong>:a) - Doing all the installation of the system.b) - Earth connections: <strong>SESAME</strong> shall do the earth connection from each station to theconnection point nearby provided by <strong>SESAME</strong> as well.c) - Connection of interlock cables from the radiation monitors to PSS.d) - Cable trays installation.e) - Installation of local plugs for data transmission “Serial or Ethernet sockets” in thehall around the Booster tunnel nearby each of the monitor station and One in the ControlRoom.f) - Electrical Power plugs (MK sockets, 230V, 50Hz) nearby each of the monitorstations.g) - Cabling from data connection points to the Control room.h)- Setup and start-up test (functioning and verification) will be done in situ, includingthe configuration of the Powerful computer workstation in the control room.i)- Powerful computer workstation will be supplied and installed by <strong>SESAME</strong> in thecontrol room and installation the software as well.5:3 Noise levela- The different radiation monitors are located in place where the noise andelectromagnetic emissions shall be kept under control.b- During the production of these devices, the supplier should proof that theserequirements have been followed. The proof shall be attached with the deliverydocumentation. NO electromagnetic signal (apart from X and Gamma rays) will affect tothe detectors.c- Chapter 9 and 11 of the applicable standards IEC 60846 and 61005 respectively withreference to the IEC 61000 relevant (or equivalent standards) should be fulfilled.d- In particular, <strong>SESAME</strong> uses a remote control for the Experimental Hall crane with afrequency range of 914.150 to 915.875MHz. This radio frequency should not have anyinfluence on the measurement devices.12