5. INSTALLATION AND START-UP5.1 General informationa- <strong>SESAME</strong> may get all lots from one bidder.b- The contractor will specify the cables for the connections of the different controlsystem components at an early stage of the contract execution.c- For the setup, the manufacture shall write an installation manual that will bedelivered to <strong>SESAME</strong> at least 6 weeks before the system delivery. This manualshall contain all the important information for the startup procedure. In addition,the contractor shall supply all the special material required for the setup.d- The electrical power installed by <strong>SESAME</strong>. The low voltage fluctuations at<strong>SESAME</strong> are ± 1% of the nominal voltage. Radiation monitors must haveswitched mode power supplies.e- Earth connection labeling is proposed and labeled by the bidder. (See Annex 4 forlabeling examples)5:2 Responsibilities of <strong>SESAME</strong>:a) - Doing all the installation of the system.b) - Earth connections: <strong>SESAME</strong> shall do the earth connection from each station to theconnection point nearby provided by <strong>SESAME</strong> as well.c) - Connection of interlock cables from the radiation monitors to PSS.d) - Cable trays installation.e) - Installation of local plugs for data transmission “Serial or Ethernet sockets” in thehall around the Booster tunnel nearby each of the monitor station and One in the ControlRoom.f) - Electrical Power plugs (MK sockets, 230V, 50Hz) nearby each of the monitorstations.g) - Cabling from data connection points to the Control room.h)- Setup and start-up test (functioning and verification) will be done in situ, includingthe configuration of the Powerful computer workstation in the control room.i)- Powerful computer workstation will be supplied and installed by <strong>SESAME</strong> in thecontrol room and installation the software as well.5:3 Noise levela- The different radiation monitors are located in place where the noise andelectromagnetic emissions shall be kept under control.b- During the production of these devices, the supplier should proof that theserequirements have been followed. The proof shall be attached with the deliverydocumentation. NO electromagnetic signal (apart from X and Gamma rays) will affect tothe detectors.c- Chapter 9 and 11 of the applicable standards IEC 60846 and 61005 respectively withreference to the IEC 61000 relevant (or equivalent standards) should be fulfilled.d- In particular, <strong>SESAME</strong> uses a remote control for the Experimental Hall crane with afrequency range of 914.150 to 915.875MHz. This radio frequency should not have anyinfluence on the measurement devices.12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!