Document Number 2620002GCode Identification 0WY55WSR-88D ROCTBDDUAL POL - DRAFTNAME DESCRIPTION FORMAT UNITS (5) RANGE LSB REMARKS HALFWORDLOCATIONAME ReceiverModuleTemperatureReal*4 deg C -40.0 to+125.00.1 N/A 61-62AME BITE/CALModuleTemperatureAME PeltierPulse WidthModulationAME PeltierStatusAME A/DConverterStatusReal*4 deg C -40.0 to+125.00.1 N/A 63-64Integer*2 % 0 to 100 1 N/A 65Integer*2 N/A 0 to 1 1 0 = OFF1 = ONInteger*2 N/A 0 to 1 1 0 = OK1 = FAILAME State Integer*2 N/A 0 to 3 1 0 = START 681 =RUNNING2 = FLASH3 = ERRORAME +3.3V PSReal*4 V 0.00 to 0.01 N/A 69-70Voltage4.09AME +5V PSReal*4 V 0.00 to 0.01 N/A 71-72Voltage6.10AME +6.5V PSReal*4 V 0.00 to 0.01 N/A 73-74Voltage7.50AME +15V PSReal*4 V 0.00 to 0.01 N/A 75-76Voltage19.00AME +48V PSReal*4 V 0.00 to 0.01 N/A 77-78Voltage60.00AME STALOReal*4 V 0.00 to 0.01 N/A 79-80Power4.09Peltier Current Real*4 A 0.00 to16.000.01 N/A 81-82ADC CalibrationReferenceVoltageReal*4 V 0.000 to2.0486667.001 N/A 83-84AME Mode Integer*2 N/A 0 to 1 1 0 = READY1 =MAINTENANCEAME PeltierModeAME PeltierInside FanCurrentAME PeltierOutside FanCurrentInteger*2 N/A 0 to 1 1 0 = COOL1 = HEAT86Real*4 A 0.00 to 0.01 N/A 87-884.00Real*4 A 0.00 to4.00850.01 N/A 89-903-34