12.07.2015 Views

GLIT051-G90 Rotors Brochure.pdf - Diamond Head Sprinkler Supply

GLIT051-G90 Rotors Brochure.pdf - Diamond Head Sprinkler Supply

GLIT051-G90 Rotors Brochure.pdf - Diamond Head Sprinkler Supply

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>G90</strong>/G95 Series <strong>Rotors</strong>Easy to adjust. Easy to maintain.It’s easy to see why Hunter rotorsare the perfect choice for the budgetminded.Through-the-top serviceability, aheavy-duty gear drive and the Pure Flowcontamination-resistant valve system arejust a few of the reasons why, for great playand beautiful results, the choice is easy.The <strong>G90</strong>/G95 from Hunter.Heavy-Duty <strong>Rotors</strong> Built to Go the DistanceFeatures & Benefits• Exclusive Pressure Port nozzling improvesdistribution uniformity• Color-coded nozzles with truly uniform coverageand fast identification• Closed case rotor assures absolute protection fromdirt and debris• Through-the-top serviceability gives easy access togear drive, riser screen and valve inlet assemblies• Proven, heavy duty impact resistant bodyprovides stability and protection from heavyequipment damage• Water activated riser seal for clean flushing actionand positive retraction• Pure Flow contamination-resistant valvesystem provides positive valve shutoff and extraprotection from dirt and dirty water


<strong>G90</strong>/95 SeriesModel Specifications<strong>G90</strong> – Full CircleG95 – Adjustable Arc (40˚ to 360˚)Model VariationsC – Check-O-Matic checks up to 25 feetin elevation changeE – Electric Valve-in-<strong>Head</strong> with pressureregulation, on-off-auto selector,190mA (370mA inrush) solenoid withcaptive plunger<strong>G90</strong> Nozzle Performance DataNozzle33Gray38Red43Dk. Brown48Dk. Green53Dk. Blue*63BlackPressurePSI708090100708090100708090100708090100708090100708090100RadiusFeet74'76'78'80'77'79'80'82'79'82'83'84'82'86'89'90'85'88'90'92'90'92'94'96'FlowGPM32.234.436.838.636.138.440.942.840.943.946.548.546.349.652.554.850.553.557.459.560.663.265.969.4Precip in/hr0.570.570.580.580.590.590.620.610.630.630.650.660.660.650.640.650.670.660.680.680.720.720.720.720.650.660.670.670.680.680.710.710.730.730.750.760.770.750.740.750.780.770.790.780.830.830.830.84G95 Nozzle Performance DataNozzle33Gray38Red43Dk. Brown48Dk. Green53Dk. Blue*63BlackPressurePSI708090100708090100708090100708090100708090100708090100RadiusFeet67'68'69'70'70'72'73'75'71'72'73'73'75'77'79'81'79'81'84'86'84'86'88'90'FlowGPM33.135.537.739.836.939.842.344.142.044.547.648.347.050.253.356.048.553.457.059.160.963.866.569.8Precip in/hr0.710.740.760.780.720.740.760.760.800.830.860.870.800.810.820.820.750.780.780.770.830.830.830.830.820.850.880.900.840.850.880.870.930.950.991.010.930.940.950.950.860.900.900.890.960.960.950.96Dimensions• Pop-up Height: 3"• Female inlet:Variation C = 1¼" ACMEVariation E = 1¼" ACME• Flange Diameter:Variation C = 7½"Variation E = 7½"• Overall height:Variation C = 12½"Variation E = 12½"Operating Specifications<strong>G90</strong>• Discharge rate: 32.2 to 69.4 gpm• Radius: 74' to 96'• Pressure range: 60 to 100 psiG95• Discharge rate: 33.1 to 69.8 gpm• Radius: 67' to 90'• Pressure range: 60 to 100 psi<strong>G90</strong> Nozzle Performance Data – MetricNozzle33Gray38Red43Dk. Brown48Dk. Green53Dk. Blue*63BlackPressureBars kPa Radiusm4.85.56.26.94.85.56.26.94.85.56.26.94.85.56.26.94.85.56.26.94.85.56.26.948255162068948255162068948255162068948255162068948255162068948255162068922.623.223.824.423.524.124.425.024.125.025.325.625.026.227.127.425.926.827.428.027.428.028.729.3Flowm 3 /hr l/min7.317.818.368.778.208.729.299.729.299.9710.5611.0210.5211.2711.9312.4511.4712.1513.0413.5213.7714.3614.9715.76S P E C I F I C A T I O N G U I D EMODEL<strong>G90</strong> = Full Circle<strong>G90</strong>C = Check-O-Matic converts toN.O. Hydraulic Valve-in-<strong>Head</strong><strong>G90</strong>E = Electric Valve-in-<strong>Head</strong>G95 = Adjustable Arc ModelsG95C = Check-O-Matic converts toN.O. Hydraulic Valve-in-<strong>Head</strong>G95E = Electric Valve-in-<strong>Head</strong>121.9130.2139.3146.1136.7145.4154.8162.0154.8166.2176.0183.6175.3187.8198.7207.4191.2202.5217.3225.2229.4239.2249.5262.7Precip mm/hr141515151515161616161717171616171717171718181818171717171717181819181919191919192020202021212121G95 Nozzle Performance Data – MetricNozzle33Gray38Red43Dk. Brown48Dk. Green53Dk. Blue*63BlackPressureBars kPa Radiusm4.85.56.26.94.85.56.26.94.85.56.26.94.85.56.26.94.85.56.26.94.85.56.26.9EXAMPLE: G-90E - 53 - P8 - S<strong>G90</strong> NOZZLES33-63 = Nozzle Factory InstalledG95 NOZZLES33-63 = Nozzle Factory InstalledSSU = #5348255162068948255162068948255162068948255162068948255162068948255162068920.420.721.021.321.321.922.322.921.621.922.322.322.923.524.124.724.124.725.626.225.626.226.827.4Flowm 3 /hr l/min7.528.068.569.048.389.049.6110.029.5410.1110.8110.9710.6811.4012.1112.7211.0212.1312.9513.4313.8314.4915.1115.86125.3134.4142.7150.7139.7150.7160.1167.0159.0168.5180.2182.8177.9190.0201.8212.0183.6202.1215.8223.7230.5241.5251.7264.2* Denotes nozzle installed in standard stocking unit (SSU).Note: All precipitation rates calculated for 360 degree operation.All triangular rates are equilateral.PRESSURE REGULATION*(Electric V.I.H. only)P7 = 70 PSI (4.8 bars; 482 kPa)P8 = 80 PSI (5.5 bars; 551 kPa)P9 = 90 PSI (6.2 bars; 620 kPa)P1 = 100 PSI (6.9 bars; 689 kPa)SSU = P8Precip mm/hr181919201819191920212222202121211920202021212121OPTIONSS = Standard212222232122222224242526242424242223232324242424Hunter Industries Incorporated • The Irrigation Innovators© 2004 Hunter Industries Incorporated1940 <strong>Diamond</strong> Street • San Marcos, California 92069 • Tel: (1) 760-744-5240 • Fax: (1) 760-471-9626www.HunterGolf.com P/N 715085 GLIT-051 1/04

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!