12.07.2015 Views

Hunter Control System Design Guide - Hunter Industries

Hunter Control System Design Guide - Hunter Industries

Hunter Control System Design Guide - Hunter Industries

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Control</strong>ler <strong>System</strong> <strong>Design</strong> <strong>Guide</strong>ChartsEach <strong>Hunter</strong> <strong>Industries</strong> electrical component has a maximum amperage draw, which must beconsidered when designing the electrical requirements of a system.As a general rule, wire should be sized for the maximum possible current for each device, since itis theoretically possible for all of the controllers on a given electrical circuit to operate at maximumcurrent simultaneously.Genesis ® /VSX Field <strong>Control</strong>lers Primary Current Requirements in Amps(<strong>Hunter</strong> VIH or ICV Valves)*LineVoltage<strong>Control</strong>lerOnlyTotals with Number of Active <strong>Hunter</strong> <strong>Industries</strong> solenoids1 2 3 4 5 6 7 8 9 10 11* 12* 13* 14*Standalone 115VAC .25 .31 .37 .42 .47 .53 .58 .63 .67 .72 .77 .81 .86 .90 .94Hardwire 115VAC .26 .32 .38 .43 .49 .54 .59 .64 .68 .73 .78 .82 .87 .91 .95Radio 115VAC .52 .58 .64 .69 .74 .79 .85 .89 .94 .98 1.03 1.07 1.11 1.16 1.20LineVoltage<strong>Control</strong>lerOnlyNumber of <strong>Hunter</strong> <strong>Industries</strong> solenoids1 2 3 4 5 6 7 8 9 10 11* 12* 13* 14*Standalone 220VAC .16 .19 .23 .26 .29 .33 .36 .39 .42 .45 .48 .50 .53 .56 .58Hardwire 220VAC .16 .20 .24 .27 .30 .33 .37 .40 .42 .45 .48 .51 .54 .56 .59Radio 220VAC .32 .36 .40 .43 .46 .49 .53 .55 .58 .61 .64 .66 .69 .72 .74* Station draws are for typical <strong>Hunter</strong> solenoids only, and are based on worst-case holding (not inrush) current.Other <strong>Hunter</strong> Components, Primary Current Requirements in AmpsComponent Line Voltage AmpsTriSend Central interface, with radio & hardwire (both)Data Retrieval, HardwireData Retrieval, RadioCWS4 Weather StationWire & Cable types used in <strong>Hunter</strong> <strong>System</strong>sGCBL Communications Cable: (Two twisted pairs,shielded & grounded):115VAC230VAC115VAC230VAC115VAC230VAC115VAC230VAC.45 max.25 max.24 max.14 max.45 max.25 max1 Amp, max.62 maxGVIKCBL1 & 2 Decoder Wire (twisted solid, red and blue):15

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!