<strong>Power</strong> 770Product Line <strong>IBM</strong> <strong>Power</strong> 770Machine type9117-MMBSystem packaging19" rack drawer (4U per node)1 – 4 nodes per CECMicroprocessor type64-bit <strong>POWER7</strong># of processor sockets per server 2, 4, 6, 8 (2 per processor card)Processor optionsGHz (cores/socket) | # of cores3.1 GHz (8) | 16, 32, 48, 643.5 GHz (6) | 12, 24, 36, 48EnergyScaleYLevel 2 (L2) cache per core256 KBLevel 3 (L3) cache per core4 MBSystem memory (minimum - maximum)32 GB – 2 TB (1066 MHz DDR3)Active Memory ExpansionOptionalReliability, availability, serviceabilityChipkill memoryYService processorRedundant SP <strong>and</strong> clock with failover (2 nodes or more)Hot-swappable disksYDynamic Processor DeallocationYProcessor Instruction RetryYAlternate Processor RecoveryYDynamic deallocation: PCI bus slotsYHot-plug PCI slotsYBlind-swap PCI slots in system unitYRedundant hot-plug powerYRedundant hot-plug coolingYNode Add, Node Repair, Memory UpgradeY eDual VIOSOptionalCapacity <strong>and</strong> exp<strong>and</strong>abilityCapacity on Dem<strong>and</strong> (CoD) functionsP, M, U, T, OO<strong>Power</strong>VM Express EditionN/A<strong>Power</strong>VM St<strong>and</strong>ard EditionOptional<strong>Power</strong>VM Enterprise EditionOptionalMax logical partitions/micro-partitions640 (10 per core)Maximum system unit PCI slots24 PCIe 8xMax PCI slots: system unit + PCI-X 12X I/O drawers24 PCIe + 192 PCI-X DDRMax PCI slots: system unit + PCIe 12X I/O drawers184 PCIeSystem unit: Disk bays | media bays24 SFF | 4 (optional)Maximum disk storage in system unit14.4 TB (with 24 600 GB disks)Maximum I/O loops (12X) 8Maximum PCI-X 12X I/O drawers 32Maximum PCIe 12X I/O drawers 16Max disk drives (system unit+I/O drawers) │ StoragePerformance*AIX rPerfGHz (cores/socket): perf (# cores)<strong>IBM</strong> i CPWGHz (cores/socket): perf (# cores)1344 | 806 TB with 600 GB drives3.1 GHz (8): 165.30(16), 306.74(32), 443.06(48), 579.39(64)3.5 GHz (6): 140.75 (12), 261.19(24), 377.28(36), 493.37(48)3.1 GHz (8): 88800(16), 155850(32), 229800(48) g , 292700(64) g3.5 GHz (6): 73100(12), 131050(24), 248550(48) g10


<strong>Power</strong> 780Product Line <strong>IBM</strong> <strong>Power</strong> 780Machine type9179-MHBSystem packaging19" rack drawer (4U per node)1 – 4 nodes per CECMicroprocessor type64-bit <strong>POWER7</strong># of processor sockets per server 2, 4, 6, 8 (2 per processor card)Processor optionsGHz (cores/socket) | # of cores3.86 GHz (8) | 16, 32, 48, 644.14 GHz (4) f | 8, 16, 24, 32 (TurboCore mode)EnergyScaleYLevel 2 (L2) cache per core256 KBLevel 3 (L3) cache per core4 MB (MaxCore mode)8 MB (TurboCore mode) fSystem memory (minimum - maximum)32 GB – 2 TB (1066 MHz DDR3)Active Memory ExpansionOptionalReliability, availability, serviceabilityChipkill memoryYService processorRedundant SP <strong>and</strong> clock with failover (2 nodes or more)Hot-swappable disksYDynamic Processor DeallocationYProcessor Instruction RetryYAlternate Processor RecoveryYDynamic deallocation: PCI bus slotsYHot-plug PCI slotsYBlind-swap PCI slots in system unitYRedundant hot-plug powerYRedundant hot-plug coolingYNode Add, Node Repair, Memory UpgradeY eDual VIOSOptionalCapacity <strong>and</strong> exp<strong>and</strong>abilityCapacity on Dem<strong>and</strong> (CoD) functionsP, M, U, T, OO<strong>Power</strong>VM Express Edition -<strong>Power</strong>VM St<strong>and</strong>ard EditionOptional<strong>Power</strong>VM Enterprise EditionOptionalMax logical partitions/micro-partitions640 (10 per core)Maximum system unit PCI slots24 PCIe 8xMax PCI slots: system unit + PCI-X 12X I/O drawers24 PCIe + 192 PCI-X DDRMax PCI slots: system unit + PCIe 12X I/O drawers184 PCIeSystem Unit: Disk bays | media bays24 SFF | 4 (optional)Maximum disk storage in system unit14.4 TB (with 24 600 GB disks)Maximum I/O loops (12X) 8Maximum PCI-X 12X I/O drawers 32Maximum PCIe 12X I/O drawers 16Max disk drives (system unit+I/O drawers) │ StoragePerformance*AIX rPerfGHz (cores/socket): perf (# cores)<strong>IBM</strong> i CPWGHz (cores/socket): perf (# cores)1344 | 806 TB with 600 GB drives3.86 GHz (8): 195.45(16), 362.70(32), 523.89(48), 685.09(64)4.14 GHz (4): 115.16(8), 226.97(16), 326.24(24), 425.50(32)3.86 GHz (8): 105200(16), 177400(32), 265200(48) g ,343050(64) g4.14 GHz (4): 57450(8), 114850(16) i , 172450(24) i , 229650(32) i11


System Unit Details (<strong>POWER7</strong> <strong>Blades</strong>)System Unit Details BladeCenterPS700 ExpressBladeCenterPS701 ExpressBladeCenterPS702 ExpressBladeCenterPS703 ExpressBladeCenterPS704 ExpressSAS Disk bays in CEC 2 SFF 1 SFF 2 SFF 1 SFF 2 SFFAvailable media bays - 1 - 1 - 1 - 1 - 1St<strong>and</strong>ard HH size - - - - -Slimline size - - - - -System ports 1 2 1 2 1 2 1 2 1 2Serial ports - - - - -USB ports 2 2 2 2 2HMC ports n/a 3 n/a 3 n/a 3 n/a 3 n/a 3Integrated Ethernetcontroller ports2 at 1 Gbps 2 at 1 Gbps 4 at 1 Gbps 2 at 1 Gbps 4 at 1 GbpsIntegrated storagecontrollers1 SAS 1 SAS 1 SAS 1 SAS 1 SASMax SAS speed 3.0 Gbps 3.0 Gbps 3.0 Gbps 3.0 Gbps 3.0 GbpsProtected write cachefor integrated SAS- - - - -controllerOptional more disk- -- - -bays with write cachePCIe expansion slotsPCIe CIOv 1 1 2 1 2PCIe CFFh 1 1 2 1 2Max PCIe bus speed(GHz)2.5 2.5 2.5 5.0 5.0LED diagnostics Y Y Y Y Y123Media bay available in BladeCenter H or S chassisSerial over LAN (SOL) connection from service processor on blade to Adv. Mgmt. Module in BlaceCenter chassis.HMC not used. Use either SDMC or IVM for consoles specialized functions13


System Unit Details (<strong>POWER7</strong> <strong>Servers</strong>)System Unit Details <strong>Power</strong> 755 <strong>Power</strong> 770 Node <strong>Power</strong> 780 Node <strong>Power</strong> 795SAS Disk bays in CEC 8 SFF 6 SFF 6 SFF -Available media bays 1 1 1 2 in media drawerSt<strong>and</strong>ard HH size - - - 1 for opt. tapeSlimline size 1 for DVD-RAM 1 for opt. DVD-RAM 1 for opt. DVD-RAM 1 for opt. DVDSystem / serial ports 2 1 1 1 -Serial ports - 1 1 -USB ports 3 3 (9 max per system) 3 (9 max per system) -HMC ports 2 2 (4 max per system) 2 (4 max per system) 4Integrated Ethernetcontroller portsIntegrated storagecontrollers4 at 1 Gbpsor2 at 10 Gbps4 at 1 Gbpsor2 at 1 Gbps, 2 at 10 Gbps4 at 1 Gbpsor2 at 1 Gbps, 2 at 10 Gbps1 SAS/SATA 2 SAS, 1 SATA (media) 2 SAS, 1 SATA (media) -Max SAS speed 3.0 Gbps 3.0 Gbps 3.0 Gbps 3.0 GbpsProtected write cache Optional dual 175 MB. Optional dual 175 MB. Optional dual 175 MB.for integrated SAS enable RAID 5/6 & help enable RAID 5/6 & help enable RAID 5/6 & helpN/Acontrollerdisk performance disk performance disk performanceOptional more diskbays with write cachevia external SAS portYes, 12 SAS withEXP12S #5886Yes, 12 SAS per nodewith EXP12S #5886Yes, 12 SAS per nodewith EXP12S #5886PCI adapter slots 5 8 8 -PCIe 8x Long 1 8 8 -PCIe 8x Short 2 2 - - -PCI-X DDR Long 2 - - -Maximum PCI-X busspeed (MHz)Max PCIe bus speed(GHz)266 - - 2662.5 2.5 2.5 2.5GX adapter slots1 GX++ 2 GX++ 2 GX++PCIe 12X I/O drawers - Up to 4 Up to 4 Up to 32 3PCI-X DDR 12X I/Odrawers- Up to 8 Up to 8 Up to 30LED diagnostics Y Y Y Y-N/A123AIX uses only for modem <strong>and</strong> async terminal connections. Not supported by AIX when HMC ports are connected toHardware Management Console. <strong>IBM</strong> i can use for status link to UPS.Each GX+ <strong>and</strong> GX++ I/O loop adapter occupies same space as one PCIe short slot.Total number of 12X PCIe I/O drawers per system is 32. The maximum for I/O drawer #5873 is 31.15


Server I/O DrawersDrawerServer Loop PCI Slots per Disk Bays per <strong>POWER7</strong> Max Drwrs FootprintAttachment Drawer Drawer Availability per Loop#579714 PCI-X DDR +12X SDR6 PCI-X16 SCSI Y 1 24” rack#579814 PCI-X DDR +12X SDR6 PCI-X16 SCSI Y (supported) 1 24” rack#5803 12X DDR 20 PCIe 26 SFF SAS Y 1 24” rack#5873 12X DDR 20 PCIe 0 Y 1 24” rack7314-G30 12X SDR 6 PCI-X DDR 0 w/d mig 4 19" rack ½ 4U 2#5796 12X SDR 6 PCI-X DDR 0 Y 4 19" rack ½ 4U 2#5802 12X DDR 1 10 PCIe 18 SFF SAS Y 2 19” rack#5877 12X DDR 1 10 PCIe 0 Y 2 19” rackEXP24 7031-D24 n/a 0 24 SCSI w/d, mig n/a 19" rack 4UEXP24 #5786 n/a 0 24 SCSI w/d, mig n/a 19" rack 4UEXP12S #5886 n/a 0 12 SAS Y n/a 19" rack 2UEXP24S #5887 n/a 0 24 SAS Y n/a 19” rack 2U12w/dmigYn/aRuns at DDR (Double Data Rate) speed assuming GX adapter <strong>and</strong> 12X cable are also DDR. Otherwise runs at SDR.Logically two drawers in one 4-U foot print. Drawers can be configured on the same or different loops.Withdrawn from marketing, not orderable from <strong>IBM</strong> ManufacturingMigrate - Attachment of existing I/O units supportedNew I/O drawers orderable from <strong>IBM</strong> ManufacturingNot applicableServer I/O Drawer Attachment(inclusion in list does not necessarily mean can order new drawers)ServerDrawer 1<strong>Power</strong>710 / 730Express0 Loops<strong>Power</strong> 720Express0-1 Loops<strong>Power</strong> 740Express0-2 Loops<strong>Power</strong> 750Express0-2 Loops<strong>Power</strong> 7550 Loops<strong>Power</strong> 7700-8 Loops<strong>Power</strong> 7800-8 Loops<strong>Power</strong> 7951-32 loops#5797 0 0 0 0 0 0 0 30#5798 0 0 0 0 0 0 0 30#5803 0 0 0 0 0 0 0 32#5873 0 0 0 0 0 0 0 317314-G30 0 Max 8 4 Max 8 Max 8 0 Max 32 Max 32 0#5796 0 Max 8 4 Max 8 Max 8 0 Max 32 Max 32 0EXP24 7031-D240 Max 24 4 Max 24 Max 24 0 Max 60 Max 60 110EXP24 #5786 2 0 Max 24 4 Max 24 Max 24 0 Max 60 Max 60 110#5802 0 Max 2 4 Max 4 Max 4 0 Max 16 Max 16 0#5877 0 Max 2 4 Max 4 Max 4 0 Max 16 Max 16 0EXP12S#5886EXP24S#5887Max 8 3 Max 28 4 28 Max 48 Max 13 Max 110 Max 110 Max 185Max 4 3 Max 14 4 Max 14 Max 24 Max 7 Max 56 Max 56 Max 1681234Though you can mix 12X PCI-X DDR I/O drawers with 12X PCIe I/O drawers on a system with two or more loops,within a loop it must be all PCIe or all PCI-X DDR I/O drawers.In addition to the #5786, the EXP24 #5787 Disk Tower is supported, but not orderable, on the <strong>Power</strong> 750, 770 <strong>and</strong> 780.Disk-only I/O drawers are not supported on 4-core <strong>Power</strong> 710 Express configurations.12X I/O drawers or disk-only drawers are not supported on 4-core <strong>Power</strong> 720 Express configurations.For Additional I/O <strong>and</strong> I/O Adapter Information - Please reference the sales manual16


Physical Planning Characteristics (<strong>POWER7</strong> <strong>Servers</strong>)Note: More comprehensive information may be found in the <strong>IBM</strong> Site <strong>and</strong> Hardware Planning document) athttp://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp?topic=/iphad/sysreq.htm. Plus, additional summaryinformation can be found in the <strong>IBM</strong> Sales Manual for each server at ibm.com/common/ssiServer <strong>Power</strong> 710Express<strong>Power</strong> 720Express<strong>Power</strong> 730Express<strong>Power</strong> 740Express<strong>Power</strong> 750ExpressPackaging19" rack drawer(2U)19" rack drwr (4U)+ tower19" rack drawer(2U)19" rack drwr (4U)+ tower19" rack drawer(4U)Voltage (AC)100 -127 (1-ph.) 100 -127 (1-ph.)200 - 240 (1-ph.) 200 - 240 (1-ph.)200 - 240 (1-ph.) 200 - 240 (1-ph.) 200 - 240 1-phase<strong>Power</strong> supply N +1 optional N +1 optional N +1 st<strong>and</strong>ard N +1 st<strong>and</strong>ard N +1 st<strong>and</strong>ardMaximum altitudefeet 10000 10000 10000 10000 10000meters 3048 3048 3048 3048 3048Server <strong>Power</strong> 755 <strong>Power</strong> 770 * <strong>Power</strong> 780 * <strong>Power</strong> 795Packaging 19" rack drawer (4U) 19" rack drawer (4U) 19" rack drawer (4U) 24" system frame(+expansion frames)Voltage (AC) 200 - 240 1-phase 200 - 240 1-phase 200 - 240 1-phase 200 – 240 (3-phase)380 – 415 (3-phase)480 – 510 (3-phase)<strong>Power</strong> supply N +1 st<strong>and</strong>ard N+1 st<strong>and</strong>ard N+1 st<strong>and</strong>ard N+1 st<strong>and</strong>ardMaximum altitudefeet 10000 10000 10000 10000meters 3048 3048 3048 3048* Figures are for a single building block or node. Up to 4 nodes per system.** For system configurations installing above 2400 meters, additional ambient room temperature limits are in effect. Please refer to the Site<strong>and</strong> Hardware Planning Guide for details.19-inch I/O Drawer #5802 #5877 7314-G30 or #579612X DDR attach,10 PCIe slots,12X DDR attach,10 PCIe slots,12X SDR attach,6 PCI slots18 disk bay0 disk bayPackaging 19" rack drawer 19" rack drawer 19" rack drawerRack space 1 unit in 4U space 1 unit in 4U space 2 units fit side by sidein 4U space<strong>Power</strong> supply N+1 st<strong>and</strong>ard N+1 st<strong>and</strong>ard N+1 st<strong>and</strong>ardVoltage 200-240V, single phase 200-240 V, single phase 200-240 V, single phaseMaximum altitudefeet 10000 10000 10000meters 3048 3048 3048Racks 7014-S25 or #0555 7014-T00 or #0551 7014-T42 or #0553 7014-B4225U 36U 42U 42UHeightinches 49.0 71.0 – 75.8 79.3 79.3millimeters 1344 1804 – 1926 2015 2015Width (can vary depending on use of side panels)inches 23.8 24.5 – 25.4 24.5 - 25.4 24.5 - 25.4millimeters 605 623 – 644 623 - 644 623 - 644Depth (can vary depending on door options selected)inches 39.4 41.0 – 45.2 41.0 - 45.2 41.0 - 55.5millimeters 1001 1042 – 1098 1043 - 1098 1042 - 140918


Warranty 1Warranty ServiceLevelsBladeCenterPS700, PS701 &PS702, PS703 &PS704 Express&BladeCenterChassis H, HT, S<strong>Power</strong> 710Express<strong>Power</strong> 720Express<strong>Power</strong> 730Express<strong>Power</strong> 740Express<strong>Power</strong> 750Express24x7 with two hour2service objectiveOptional Optional Optional Optional Optional Optional24x7 with four hourservice objectiveOptional Optional Optional Optional Optional Optional9x5 with four hourservice objectiveOptional Optional Optional Optional Optional Optional9x5 next-business-day St<strong>and</strong>ard 3 St<strong>and</strong>ard 3 St<strong>and</strong>ard 3 St<strong>and</strong>ard 3 St<strong>and</strong>ard 3 St<strong>and</strong>ard 3Warranty Period 3 years 3 years 3 years 3 years 3 years 1 yearWarranty ServiceLevels<strong>Power</strong> 755 <strong>Power</strong> 770 <strong>Power</strong> 780 <strong>Power</strong> 79524x7 with two hour2service objectiveOptional Optional Optional Optional24x7 with four hourservice objectiveOptional Optional St<strong>and</strong>ard St<strong>and</strong>ard9x5 with four hourservice objectiveOptional Optional - -9x5 next-business-day St<strong>and</strong>ard 3 St<strong>and</strong>ard 3 - -Warranty Period 1 year 1 year 1 year 1 year123These warranty terms <strong>and</strong> conditions are for the United States <strong>and</strong> may be different in other countries. Consult your local<strong>IBM</strong> representative or <strong>IBM</strong> Business Partner for country-specific information.Available in selected cities.M<strong>and</strong>atory Customer Replaceable Unit (CRU) <strong>and</strong> On-site service.19


<strong>Power</strong> <strong>Systems</strong> Express <strong>Blades</strong> <strong>and</strong> <strong>Servers</strong> Software Support<strong>Power</strong> <strong>Systems</strong>SoftwareBladeCenterPS700ExpressBladeCenterPS701/PS702Express<strong>Power</strong> 710Express<strong>Power</strong> 720Express<strong>Power</strong> 730Express<strong>Power</strong> 740Express<strong>Power</strong> 750ExpressSoftware Tier Small Small Small Small Small Small Small<strong>Power</strong>VM<strong>Power</strong>VM Express Supported Supported Supported Supported Supported Supported Supported<strong>Power</strong>VM St<strong>and</strong>ard <strong>and</strong>Enterprise EditionsSupported Supported Supported Supported Supported Supported SupportedAIXAIX 5.3St<strong>and</strong>ard EditionAIX 6.1Express 1 St<strong>and</strong>ard <strong>and</strong>Enterprise EditionsAIX 7.1Express 1 , St<strong>and</strong>ard <strong>and</strong>Enterprise EditionsAIX 5.2 WorkloadPartitions for AIX 7<strong>IBM</strong> i<strong>IBM</strong> i Software Tier<strong>IBM</strong> i 6.1.1Express, St<strong>and</strong>ard <strong>and</strong>Enterprise Editions<strong>IBM</strong> i 7.1Express, St<strong>and</strong>ard <strong>and</strong>Enterprise EditionsLinuxRed Hat EnterpriseLinux 5.5Red Hat EnterpriseLinux 6Novell SUSE LinuxEnterprise Server 10SP3Novell SUSE LinuxEnterprise Server 11<strong>Power</strong>HA<strong>Power</strong>HA SystemMirrorfor AIX 6.1 2 St<strong>and</strong>ard<strong>and</strong> Enterprise Editions<strong>Power</strong>HA SystemMirrorfor AIX 7 2 St<strong>and</strong>ardEdition<strong>Power</strong>HA SystemMirrorfor i 6.1<strong>Power</strong>HA SystemMirrorfor i 7.1 St<strong>and</strong>ard <strong>and</strong>Enterprise EditionsSupportedTL 12SupportedTL 5SupportedTL 12SupportedTL 5SupportedTL 10/11/12SupportedTL 3/4/5/6SupportedTL 10/11/12SupportedTL 3/4/5/6SupportedTL 10/11/12SupportedTL 3/4/5/6SupportedTL 10/11/12SupportedTL 3/4/5/6SupportedTL 9/10/11/12SupportedTL 2/3/4/5Supported Supported Supported Supported Supported Supported SupportedSupported Supported Supported Supported Supported Supported SupportedSmallP05SmallP10SmallP05(4-core)P10(6/8-core)SmallP05(4-core)P10(6/8-core)SmallP20SmallP20SmallP20Supported Supported Supported Supported Supported Supported SupportedSupported Supported Supported Supported Supported Supported SupportedSupported Supported Supported Supported Supported Supported SupportedSupported Supported Supported Supported Supported Supported SupportedSupported Supported Supported Supported Supported Supported SupportedSupportedSP1SupportedSP1SupportedSP1SupportedSP1SupportedSP1SupportedSP1SupportedSupported Supported Supported Supported Supported Supported SupportedSupported Supported Supported Supported Supported Supported SupportedSupported Supported Supported Supported Supported Supported SupportedSupported Supported Supported Supported Supported Supported Supported<strong>IBM</strong> <strong>Systems</strong> Director for <strong>Power</strong>Express, St<strong>and</strong>ard <strong>and</strong>Supported Supported Supported Supported Supported Supported SupportedEnterprise Editions1 – Note that AIX 6.1 <strong>and</strong> AIX 7.1 Express Edition may be used for partitions of up to 4 cores <strong>and</strong> 8 GB of memory per core.2 -- <strong>Power</strong>HA SystemMirror for AIX 6.1 is supported with both AIX 5.3 <strong>and</strong> AIX 6.1. <strong>Power</strong>HA SystemMirror for AIX 7 is supported with both AIX 6.1 <strong>and</strong> AIX 7.1.20


<strong>Power</strong> <strong>Systems</strong> <strong>Servers</strong> Software Support<strong>Power</strong> <strong>Systems</strong>Software<strong>Power</strong> 755 <strong>Power</strong> 770 <strong>Power</strong> 780 <strong>Power</strong> 795Software Tier Small Medium Large Large<strong>Power</strong>VM<strong>Power</strong>VM Express N/A N/A N/A N/A<strong>Power</strong>VM St<strong>and</strong>ard <strong>and</strong>Enterprise EditionsN/A Supported Supported SupportedAIXAIX 5.3St<strong>and</strong>ard EditionAIX 6.1Express 1 , St<strong>and</strong>ard <strong>and</strong>Enterprise EditionsAIX 7.1Express 1 , St<strong>and</strong>ard <strong>and</strong>Enterprise EditionsAIX 5.2 WorkloadPartitions for AIX 7<strong>IBM</strong> i<strong>IBM</strong> i Software TierSupportedTL 9/10/11/12SupportedTL 2/3/4/5SupportedTL 9/10/11/12SupportedTL 2/3/4/5SupportedTL 9/10/11/12SupportedTL 2/3/4/5SupportedTL 10/11/12SupportedTL 6SOD 2 -TL 3/4/5Supported Supported Supported SupportedSupported Supported Supported SupportedN/A<strong>IBM</strong> i 6.1.1Express, St<strong>and</strong>ard <strong>and</strong>Enterprise Editions<strong>IBM</strong> i 7.1Express, St<strong>and</strong>ard <strong>and</strong>Enterprise EditionsLinuxRed Hat EnterpriseLinux 5.5Red Hat EnterpriseLinux 6Novell SUSE LinuxEnterprise Server 10 SP3Novell SUSE LinuxEnterprise Server 11<strong>Power</strong>HA<strong>Power</strong>HA SystemMirrorfor AIX 6.1 3 St<strong>and</strong>ard <strong>and</strong>Enterprise Editions<strong>Power</strong>HA SystemMirrorfor AIX 7 3 St<strong>and</strong>ardEdition<strong>Power</strong>HA SystemMirrorfor i 6.1<strong>Power</strong>HA SystemMirrorfor i 7.1 St<strong>and</strong>ard <strong>and</strong>Enterprise Editions<strong>IBM</strong> <strong>Systems</strong> Director for <strong>Power</strong>Express, St<strong>and</strong>ard <strong>and</strong>Enterprise EditionsMediumP30LargeP50LargeP50N/A Supported Supported SupportedN/A Supported Supported SupportedSupported Supported Supported SupportedSupported Supported Supported SupportedSupported Supported Supported SupportedSupported Supported SupportedSupportedSP1N/A Supported Supported SupportedN/A Supported Supported SupportedN/A Supported Supported SupportedN/A Supported Supported SupportedN/A Supported Supported Supported1 – Note that AIX 6.1 <strong>and</strong> AIX 7.1 Express Edition may be used for partitions of up to 4 cores <strong>and</strong> 8 GB of memory per core.2 – <strong>IBM</strong> Statement of Direction to support AIX 6.1 TL 3 SP7, TL4 SP7 <strong>and</strong> TL5 SP3 on the <strong>Power</strong> 795 server.3 – <strong>Power</strong>HA SystemMirror for AIX 6.1 is supported with both AIX 5.3 <strong>and</strong> AIX 6.1. <strong>Power</strong>HA SystemMirror for AIX 7 is supported with both AIX 6.1 <strong>and</strong> AIX 7.1.21


Performance NotesThe performance information contained herein is current as of the date of this document. All performancebenchmark values <strong>and</strong> estimates are provided “AS IS” <strong>and</strong> no warranties or guarantees are expressed or impliedby <strong>IBM</strong>. Buyers should consult other sources of inform ation, including system benchmarks, to evaluate theperformance of a system they are considering.rPerf (Relative Performance) is an estimate of commerc ial processing performance relative to other <strong>IBM</strong> UNIX®systems. It is derived from an <strong>IBM</strong> analytical model which us es characteristics from <strong>IBM</strong> internal workloads, TPC<strong>and</strong> SPEC benchmarks. The rPerf model is not intended to represent any sp public benchmark results <strong>and</strong>should not be reasonably used in that way. The model si mulates some of the system operations such as CPU,cache <strong>and</strong> memory. However, the model does not simulate disk or network I/O operations.rPerf estimates are calculated based on systems with the la test levels of AIX <strong>and</strong> other pertinent software at thetime of system announcement. Actual performance will va ry based on application <strong>and</strong> guration speci cs. The<strong>IBM</strong> eServer pSeries® 640 is the baseline reference sy stem <strong>and</strong> has a value of 1.0. Although rPerf may beused to approximate relative <strong>IBM</strong> UNIX commercial proc essing performance, actual system performance mayvary <strong>and</strong> is dependent upon many factors including sy stem hardware guration <strong>and</strong> software design <strong>and</strong>guration. Note that the rPerf me thodology used for the POWER6 processor- based systems is identical to thatused for the POWER5 processor-based systems. Variati ons in incremental system performance may be observedin commercial workloads due to changes in the underlyi ng system architecture. For additional information aboutrPerf, contact your local <strong>IBM</strong> or <strong>IBM</strong> authorized reseller.Commercial Processing Workload (CPW) is a relative measure of performance of systems running the <strong>IBM</strong> ioperating system. Performance in client environments ma y vary. The value is based on maximum gurations.Please refer to the “<strong>IBM</strong> <strong>Power</strong> <strong>Systems</strong> Performance Capabilities Reference—<strong>IBM</strong> i operating system Version6.1” at the following Web site for a complete descrip tion of CPW <strong>and</strong> the CPW ra ting for <strong>IBM</strong> <strong>Power</strong> <strong>Systems</strong>.(ibm.com/systems/i/advantages/perfmgmt/pdf.pcrm.pdf )All performance estimates are provided “AS IS” <strong>and</strong> no wa rranties or guarantees are expressed or implied by<strong>IBM</strong>. Buyers should consult other sources of informat ion, including system benc hmarks <strong>and</strong> application sizingguides to evaluate the performance of a system they are considering buying. Actual system performance mayvary <strong>and</strong> is dependent upon many factors including sy stem hardware guration <strong>and</strong> software design <strong>and</strong>guration. <strong>IBM</strong> recommends application-oriented testi ng for performance predictions. Additional informationabout the performance benchmarks, values <strong>and</strong> system s tested is available from your <strong>IBM</strong> marketingrepresentative or <strong>IBM</strong> Authorized Reseller or access the following on the Web:SPEC – http://www.spec.org TPC – http://www.tpc.orgMore information• Contact your <strong>IBM</strong> Business PartnerIng. Mariano Esterlus<strong>IBM</strong> <strong>Power</strong> <strong>Systems</strong> SSRAvnet Technology Solutions ArgentinaEsmeralda 715 4to piso - Buenos Airesmariano.esterlus@avnet.comwww.ats.avnet.com• Access the <strong>Power</strong> <strong>Systems</strong> Products <strong>and</strong> Serv ices page on <strong>IBM</strong>’s World Wide Web server atibm.com/systems/power <strong>and</strong> then select the appropriate hardware or software option• Product announcement letters <strong>and</strong> Sales Manual containing more details on hardware <strong>and</strong> softwaregs are available at ibm.com/common/ssi• More detailed benchmark <strong>and</strong> performance information is available atibm.com/systems/p/hardware/benchmarks , ibm.com/systems/p/hardware/system_perf.html <strong>and</strong> atibm.com/systems/i/solutions/p erfmgmt/resource.html .22


© <strong>IBM</strong> Corporation 2011<strong>IBM</strong> CorporationIntegrated Marketing Communications<strong>Systems</strong> <strong>and</strong> Technology GroupRoute 100Somers, New York 10589Produced in the United States of AmericaJune 2011All Rights ReservedThis document was developed for products <strong>and</strong>/or services offered in the United States. <strong>IBM</strong> may not offer the products, features or servicesdiscussed in this document in other countries. The information may be subject to change without notice. Consult your local <strong>IBM</strong> businesscontact for information on the products, features <strong>and</strong> services available in your area.All statements regarding <strong>IBM</strong> future directions <strong>and</strong> intent are subject to change or withdrawal without notice <strong>and</strong> represent goals <strong>and</strong>objectives only. These are identified by SOD.<strong>IBM</strong>, the <strong>IBM</strong> logo, Active Memory, AIX, BladeCenter, EnergyScale, <strong>Power</strong>, POWER, POWER6, POWER6+, <strong>POWER7</strong>, <strong>Power</strong>HA, <strong>Power</strong>VM,<strong>Power</strong> <strong>Systems</strong> <strong>and</strong> <strong>Power</strong> <strong>Systems</strong> Software are trademarks or registered trademarks of International Business Machines Corporation in theUnited States or other countries or both. A full list of U.S. trademarks owned by <strong>IBM</strong> may be found at ibm.com/legal/copytrade.shtml .The <strong>Power</strong> Architecture <strong>and</strong> <strong>Power</strong>.org wordmarks <strong>and</strong> the <strong>Power</strong> <strong>and</strong> <strong>Power</strong>.org logos <strong>and</strong> related marks are trademarks <strong>and</strong> service markslicensed by <strong>Power</strong>.org .UNIX is a registered trademark of the Open Group in the United States, other countries or both.Linux is a registered trademark of Linux Torvalds in the United States, other countries or both.TPC-C <strong>and</strong> TPC-H are trademarks of the Transaction Performance Processing Council (TPPC).SPECint, SPECfp, SPECjbb <strong>and</strong> SPECweb are trademarks of the St<strong>and</strong>ard Performance Evaluation Corp (SPEC).InfiniB<strong>and</strong>, InfiniB<strong>and</strong> Trade Association <strong>and</strong> the InfiniB<strong>and</strong> design marks are trademarks <strong>and</strong>/or service marks of the InfiniB<strong>and</strong> TradeAssociation.Other company, product <strong>and</strong> service names may be trademarks or service marks of others.<strong>IBM</strong> hardware products are manufactured from new parts or new <strong>and</strong> used parts. Regardless, our warranty terms apply.Photographs show engineering <strong>and</strong> design models. Changes may be incorporated in production models.Copying or downloading the images contained in this document is expressly prohibited without the written consent of <strong>IBM</strong>.This equipment is subject to FCC rules. It will comply with the appropriate FCC rules before final delivery to the buyer.Information concerning non-<strong>IBM</strong> products was obtained from the suppliers of these products or other public sources. Questions on thecapabilities of the non-<strong>IBM</strong> products should be addressed with the suppliers.All performance information was determined in a controlled environment. Actual results may vary. Performance information is provided “AS IS”<strong>and</strong> no warranties or guarantees are expressed or implied by <strong>IBM</strong>.When referring to storage capacity, total TB equals total GB divided by 1000; accessible capacity may be less.The <strong>IBM</strong> home page on the Internet can be found at ibm.com .This brochure provides detailed technical specifications of all <strong>IBM</strong> <strong>POWER7</strong> processor-based <strong>Power</strong> <strong>Systems</strong> servers <strong>and</strong> BladeCenterblades in a tabular, easy-to-scan format for easy comparison between systems. These systems are UNIX (AIX), <strong>IBM</strong> i <strong>and</strong> Linux operatingsystem servers. Not all features listed in this document are available on all three operating systems.POB03022-USEN-1023