2006 International Building Code• SECTION 1605 LOAD COMBINATIONS• 1605.2 Load combinations using strengthdesign or load <strong>and</strong> resistance factor design1605.2.1 Basic load combinations1.2D + 1.6(L r or S or R) + (f 1 L or 0.8W)1.2D + 1.6W + f 1 L + 0.5(L r or S or R)0.9D + 1.6W0.9D + 1.0ENOTE: F <strong>and</strong>/or H loads have been left outof the above equations<strong>SEAoT</strong> State Conference November 6-8, 2008 Houston TX <strong>SEAoT</strong> - 23