12.07.2015 Views

4 ac motor controller 220-240 V ac Wm-o - Somfy Architecture

4 ac motor controller 220-240 V ac Wm-o - Somfy Architecture

4 ac motor controller 220-240 V ac Wm-o - Somfy Architecture

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

4 AC Motor Controller <strong>220</strong>-<strong>240</strong> V AC WM-Oanimeo Solo animeo IB+ animeo KNX animeo LONSolutions for commercial buildingsMotor <strong>controller</strong> for roller shutters, screens and exterior Venetianblinds.To individually control four 230 V AC <strong>motor</strong>s through <strong>Somfy</strong> RTStechnology.Autonomous solution for energy saving and user comfort.Ref. 1860231Installation advantagesFunctional advantages> Simple integration of Philips Occuswitch and the <strong>Somfy</strong>-Philipsinterf<strong>ac</strong>e.> Quick installation and connection of the Motor Controllerthrough:1. Integrated strain relief. More safety without additionalexpenditure.2. Spring tension terminals and double terminals. Time savingsthrough not having a junction box.3. Generous design. More sp<strong>ac</strong>e for the connection of singlecables.4. Status feedb<strong>ac</strong>k through LED’s.> Automatic switching between manual and automatic prioritydepending on presence and absence based on room level.> Local user overwrite through <strong>Somfy</strong> radio technolgy RTS.> Smooth dimming of artificial light through Philips Occuswitch.WiringClassificationConnection Cables TwistedpairsMax.distanceThe Motor Controller is an electronically and manually-operated,independently-mounted control.MotorsPhilipsOSD interf<strong>ac</strong>eMin.: 3 x 0.6 mm/22 AWGMax.: 3 x 2.5 mm 2 /14 AWGMin.: 3 x 0.6 mm/22 AWGMax.: 3 x 2.5 mm 2 /14 AWG<strong>220</strong>-<strong>240</strong> V AC Min.: 3 x 1.5 mm 2 /16 AWGMax.: 3 x 2.5 mm 2 /14 AWG— 20 mRecommended 100 m—• Class A control function• Type 1 <strong>ac</strong>tion• Pollution degree: 2• Rated impulse voltage: 4 kV• Temperature of the ball hardness test: 75 ° C• Type X att<strong>ac</strong>hment• Method of att<strong>ac</strong>hment for non-det<strong>ac</strong>hable cords:screwless spring terminal• EMC emission test: U AC= 230 V AC I AC= 0.5 A(EN 55022 Class B emission)


4 <strong>ac</strong> <strong>motor</strong> <strong>controller</strong> <strong>220</strong>-<strong>240</strong> V <strong>ac</strong> <strong>Wm</strong>-oSolutionS for commercial buildingSMotor 230 V/50 HzMotor 1Motor 230 V/50 HzMotor 2Motor 230 V/50 HzMotor 3Motor 230 V/50 HzMotor 4M˜M˜M˜M˜PENUPDownPENUPDownPENUPDownPENUPDownL1NPE-mains230 V50 HzL L N N PE PE PE NPE NPE NM1M2M3F 3.15 AHF 3.15 AHF 3.15 AH<strong>Somfy</strong>animeo IB+Ext.4 AC Motor Controller WM-O <strong>220</strong>-<strong>240</strong> V ACIB1860231IB+ InIBCIB+ OutIBCReset / Prog1 2 3 4M1C0.75 2Junctionbox1 2 3 4M2C0.75 2Junctionbox1 2 3 4M3C0.75 2Junctionbox1 2 3 4PE NM4F 3.15 AHM4C0.75 2JunctionboxExt.A BanimeoRTS module 433.42 MHz1860105GroupcontrolCUPDownIB+<strong>Somfy</strong>animeo IB+4 AC Motor Controller WM-O <strong>220</strong>-<strong>240</strong> V ACPhilipsOSD Interf<strong>ac</strong>ePhilipsMotion SensorRef. 9018301 Ref. 9018305PhilipsMotion SensorPhilipsOSD Interf<strong>ac</strong>eM1CM2CM3C1 2 3 4M4CXDAPHILIPSLCU2080/00OSD <strong>Somfy</strong> Interf<strong>ac</strong>eNLNLDALILRM2080/XXCHARACTERISTICSSupply voltage<strong>220</strong>-<strong>240</strong> V AC / 50/60 HzStand-by current (iec 62301)< 3 mA @ 230 V ACStand-by power (iec 62301)< 0,5 <strong>Wm</strong>ax. <strong>motor</strong> current consumption 4 x 3.0 A, cos ϕ = 0.95Supply voltage of group control input SELV, 16 V DC =Supply voltage of local push buttons SELV, 16 V DC =fuse for all outputs4 x F 3.15 AHterminalsSpring connectorsrunning time per output (relay cont<strong>ac</strong>t)Max. 5 minutesoperating temperature0 ° C to 45 ° Crelative humidity 85 %material of housingCC-ABS polycarbonateHousing dimensions (w x h x d)180 x 255 x 63 mmdegree of protection IP 20Protection classII (looped through PE connection - depending on the installation)conformitywww.somfy.com/ce

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!