PRODUCT DATAAmerican Standard Heating & Air ConditioningGeneralDataProduct SpecificationsModel No. 1 <strong>4A7B3</strong>042D1 <strong>4A7B3</strong>048D1 <strong>4A7B3</strong>060D1Electrical Data V/Ph/Hz 2 208/230/1/60 208/230/1/60 208/230/1/60Min Cir Ampacity 26 28 35Max Fuse Size (Amps) 45 50 60Compressor Duration ® - SCROLL Duration ® - SCROLL Duration ® - SCROLLRL Amps - LR Amps 19.9 - 105 21.8 - 117 26.8 - 134Outdoor Fan FL Amps 1.0 1.0 1.0Fan HP 1/5 1/5 1/5Fan Dia (inches) 27.5 27.5 27.5Coil Spine Fin Spine Fin Spine FinRefrigerant R-410A 9/2-LB/OZ 6/13-LB/OZ 8/0-LB/OZLine Size - (in.) O.D. Gas 3 3/4 7/8 7/8Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8Charge Spec. Subcooling 10° 10° 10°Dimensions H x W x D (Crated) 34.4 x 35.1 x 38.7 34.4 x 35.1 x 38.7 42.4 x 35.1 x 38.7Weight - Shipping 228 235 261Weight - Net 196 203 226Start Components NO NO NOSound Enclosure NO NO NOCompressor Sump Heat NO NO NOOptional Accessories: 4Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501AEvaporator Defrost Control AY28X079 AY28X079 AY28X079Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004Start Kit BAYKSKT263 BAYKSKT263Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103Refrigerant Lineset 5 TAYREFLN7* TAYREFLN3* TAYREFLN3*Accessory Description and UsageAnti-Short Cycle Timer — Solid state timing device that preventscompressor recycling until five (5) minutes have elapsedafter satisfying call or power interruptions. Use in area withquestionable power delivery, commercial applications, longlineset, etc.Evaporator Defrost Control — SPST Temperature actuatedswitch that cycles the condenser off as indoor coil reachesfreeze-up conditions. Used for low ambient cooling to 30°Fwith TXV.Rubber Isolators — Five (5) large rubber donuts to isolatecondensing unit from transmitting energy into mounting frameor pad. Use on any application where sound transmissionneeds to be minimized.Hard Start kit — Start capacitor and relay to assist compressormotor startup. Use in areas with marginal power supply, onlong linesets, low ambient conditions, etc.Extreme Condition Mount Kit — Bracket kits to securelymount condensing unit to a frame or pad without removing anypanels. Use in areas with high winds, or on commercial rooftops, etc.ARI Standard Capacity Rating ConditionsARI STANDARD 210/240 RATING CONDITIONS —(A) Cooling 80°F DB, 67°F WB air entering indoor coil,95°F DB air entering outdoor coil.(B) High Temperature Heating 47°F DB, 43°F WB air enteringoutdoor coil, 70°F DB air entering indoor coil.(C) Low Temperature Heating 17°F DB, 15°F WB air enteringoutdoor coil, 70°F DB air entering indoor coil.(D) Rated indoor airflow for heating is the same as for cooling.ARI STANDARD 270 RATING CONDITIONS — (Noise ratingnumbers are determined with the unit in cooling operation.)Standard Noise Rating number is at 95°F outdoor air.DATA SUBJECT TO CHANGE WITHOUT NOTICE 5


PRODUCT DATAAmerican Standard Heating & Air ConditioningModelNomenclatureOutdoor Units4 T T R 3 0 3 6 B 1 0 0 0 A AGas Furnaces A U D 2 B 0 8 0 A C V 3 2 A ARefrigerant Type2 = R-224 = R-410ATRANEProduct TypeW = Split Heat PumpT = Split CoolingProduct FamilyZ = Leadership – Two StageX = LeadershipR = Replacement/RetailB = BasicA = Light CommercialFamily SEER0 = 10 3 = 13 6 = 161 = 11 4 = 14 8 = 182 = 12 5 = 15 9 = 19Split System Connections 1-6 Tons0 = BrazedNominal Capacity in 000s of BTUsMajor Design ModificationsPower Supply1 = 200-230/1/60 or 208-230/1/603 = 200-230/3/604 = 460/3/60Secondary FunctionMinor Design ModificationsUnit Parts IdentifierAir Handlers –Residential4 T E E 3 F 3 6 A 1 0 0 0 A AHeat Pump /Cooling Coils2 T X C B 0 3 6 A C 3 H C A ARefrigerant Type4 = R-410A2 = R-22ApplicationTE = Fully ConvertibleTG = Semi ConvertibleTF = Front ReturnTV = VerticalProduct FamilyE = Leadership – Variable SpeedP = LeadershipC = Replacement/RetailB = BasicFlow Control3 = Nonbleed TXV4 = FCCV*Feature Identifier0 = Standard UnitF = Air-TiteNominal Capacity in 000s of BTUsMajor Design ModificationsPower Supply1 = Single PhaseElectrical Connection0 = Pig TailsB = Circuit BreakerD = Pull DisconnectFuture Option – Factory Installed Heater Nominal KW ValueMinor Design ModificationsUnit Parts IdentifierNOTE: There will be a phase-in of new model numbers for newair handlers over next 2 years.*Shipped with R-22 FCCVRefrigerant Type2 = R-22 4 = R-410AProduct FamilyT = Premium (Heat Pump or Convertible Coil)C = Standard (Cooling Only)Coil DesignX = Direct Expansion Evaporator CoilProduct FamilyC = Cased A CoilA = Uncased A CoilF = Cased Horizontal Flat CoilCoil Width (Cased / Uncased)A = 14.5" / 13.3" C = 21.0" / 19.8" H = 10.5"B = 17.5" / 16.3" D = 24.5" / 23.3"Refrigerant Line Coupling0 = BrazedNominal Capacity in 000s of BTUsMajor Design ChangeEfficiencyC = Standard S = Hi EfficiencyRefrigerant Control3 = TXV – Non-BleedCoil CircuitryH = Heat PumpC = Cooling OnlyAirflow ConfigurationA = Upflow OnlyU = Upflow / DownflowH = Horizontal OnlyC = Convertible – Upflow, Downflow, Left AirflowM = Convertible – Upflow, Downflow, Left or Right AirflowMinor Design ChangeUnit Parts Identifier6 DATA SUBJECT TO CHANGE WITHOUT NOTICE


PRODUCT DATAAmerican Standard Heating & Air ConditioningElectricalDataSCHEMATIC DIAGRAMS(SEE LEGEND)<strong>4A7B3</strong>018,024,030, and 036D1 <strong>4A7B3</strong>042D1DATA SUBJECT TO CHANGE WITHOUT NOTICE 7


PRODUCT DATAAmerican Standard Heating & Air ConditioningElectricalData<strong>4A7B3</strong>048 and 060D1SCHEMATIC DIAGRAMS(SEE LEGEND)PRINTED FROM D155205P01 REV008 DATA SUBJECT TO CHANGE WITHOUT NOTICE


PRODUCT DATAAmerican Standard Heating & Air ConditioningDimensions<strong>4A7B3</strong> OUTLINE DRAWINGNOTE: ALL DIMENSIONS ARE IN MM (INCHES)MODELS BASE FIG. A B C D E F G H J K<strong>4A7B3</strong>018D 3 1 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 5/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)<strong>4A7B3</strong>024D 3 1 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 5/8 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)<strong>4A7B3</strong>030D 3 1 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 3/4 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)<strong>4A7B3</strong>036D 3 1 832 (32-3/4) 829 (32-5/8) 756 (29-3/4) 3/4 3/8 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20)<strong>4A7B3</strong>042D 4 1 741 (29-1/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20)<strong>4A7B3</strong>048D 4 1 741 (29-1/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20)<strong>4A7B3</strong>060D 4 1 943 (37-1/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20)From Dwg. D15307410 DATA SUBJECT TO CHANGE WITHOUT NOTICE


PRODUCT DATAAmerican Standard Heating & Air ConditioningMechanicalSpecification OptionsGeneralThe <strong>4A7B3</strong>-D models shall be fullycharged from the factory for matched indoorsection and up to 15 feet of piping.This unit must be designed to operateat outdoor ambient temperatures ashigh as 115°F. Cooling capacities shallbe matched with a wide selection of airhandlers and furnace coils that are ARIcertified. The unit is certified to UL 1995.Exterior must be designed for outdoorapplication.CasingUnit casing is constructed of heavygauge, galvanized steel and paintedwith a weather-resistant powder paint.Corrosion and weatherproof CMBP-G30DuraTuff base.Refrigerant ControlsRefrigeration system controls includecondenser fan and compressor contactor.High and low pressure controls areinherent to the compressor. Anotherstandard feature is the liquid line dryer.CompressorThe Duration ® compressor featuresinternal over temperature and pressureprotector, total dipped hermetic motorand thermostatically controlled sumpheater. Other features include centrifugaloil pump, and low vibration and noise.Condenser CoilThe Spine Fin coil shall be continuouslywrapped, corrosion resistantall aluminum with minimum brazedjoints. This coil is 3/8 inch O.D. seamlessaluminum glued to a continuousaluminum fin. Coils are lab tested towithstand 2,000 pounds of pressure persquare inch. The outdoor coil provideslow airflow resistance and efficient heattransfer. The coil is protected on all foursides by louvered panels.Low Ambient CoolingAs manufactured, this unit has a coolingcapability to 55°F. The addition ofan evaporator defrost control permitsoperation to 30°F. The addition of a lowambient kit with TXV permits low ambientcooling to 0°F.AccessoriesThermostats — Heating/Cooling(manual and automatic changeover).Sub-base to match thermostat and lockingthermostat cover.Evaporator Defrost Control — SeeLow Ambient Cooling.Outdoor Thermostat — Supplementalheat outdoor ambient lockout from46 to –10°F.DATA SUBJECT TO CHANGE WITHOUT NOTICE 11


PRODUCT DATAAmerican Standard Heating & Air ConditioningSince the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.Technical Literature - Printed in U.S.A.American Standard Heating & Air ConditioningTroup HighwayTyler, TX 75707DATA SUBJECT TO CHANGE WITHOUT NOTICE 12