limit current curves of <strong>the</strong> insertsCTSE (16A) series CMCE and CME series CMSE seriesCP seriescurves curves curvesdiagram CTSE 06 poles1630diagram CME and CMCE 03 poles30diagram CMSE 03 polesload curvesworking current (A)1412108641,0 mm 20,5 mm 22,5 mm 21,5 mm 2working current (A)2826242220181614121081,5 mm 2 1,0 mm 22,5 mm 20,5 mm 2 4,0 mm 2 (CMCE 03)working current (A)2826242220181614121081,0 mm 2 0,5 mm 21,5 mm 22,5 mm 26624400 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)200 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)200 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)diagram CTSE 10 poles1630diagram CME and CMCE 06 poles30diagram CMSE 06 poles142,5 mm 228262,5 mm 228261,0 mm20,5 mm 2working current (A)12108641,5 mm 2working current (A)242220181614121081,5 mm 21,0 mm 2 0,5 mm 2 4,0 mm 2 (CMCE 06)working current (A)242220181614121081,5 mm 21,0 mm 2 0,5 mm 22,5 mm 26624400 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)200 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)200 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)diagram CTSE 16 poles1630diagram CME and CMCE 10 and 20 poles30diagram CMSE 10 and 20 polesworking current (A)1412108641,0 mm 2 0,5 mm 21,5 mm 22,5 mm 2working current (A)2826242220181614121081,5 mm 22,5 mm 21,0 mm 2 0,5 mm 2 4,0 mm 2 (CMCE 10-20)working current (A)2826242220181614121081,5 mm 21,0 mm 2 0,5 mm 22,5 mm 22646400 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)200 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)200 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)diagram CTSE 24 poles1630diagram CME and CMCE 16 and 32 polesdiagram CP 06 and 12 poles55working current (A)1412108641,0 mm 20,5 mm 21,5 mm 22,5 mm 2working current (A)2826242220181614121081,5 mm 22,5 mm 24,0 mm 2 (CMCE 16-32)1,0 mm 2 0,5 mm 2working current (A)50454035302520154,0 mm 2 6,0 mm 22,5 mm 2200 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)64200 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)1051,5 mm 200 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)32
limit current curves of <strong>the</strong> insertsCX 8/24 series CX 12/2 series CX 4/2 seriesCX 6/36 seriesCX 4/0 seriescurves curves curvesworking current (A)working current (A)diagram CX 8/24 power poles3028262422202,5 mm 218161,5 mm142121086441,0 mm 2 4,0 mm 2diagram CX 12/2 power poles50020 10 20 30 40 50 60 70 80 90 100 110 120 1300ambient temperature (°C)0 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)diagram CX 8/24 auxiliary poles16142,5 mm 212101,5 mm 281,0 mm 260,5 mm 2working current (A)454035302520151054,0 mm 2 6,0 mm 2working current (A)diagram CX 4/2 poles201,5 mm 2 1816141210864200 10 20 30 40 50 60 70 80 90 100 110 120 130 140ambient temperature (°C)diagram CX 4/2 poles20working current (A)load curves21,5 mm 2 1800 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)Note: for connec<strong>to</strong>r with power poles and auxiliarypoles simultaneously loaded in <strong>the</strong> combinationsgdiagram CX 4/0 polesworking current (A)10 mm 2161412108working current (A)10 mm 2 16 mm 26power polesauxiliary poles4.0 mm 2 2.5 mm 22.5 mm 2 1.5 mm 21.5 mm 2 1.0 mm 21.0 mm 2 0.5 mm 2with power / auxiliary current ratios = 1.6 / 1corrente d’esercizio (A)4200 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)70diagram CX 6/36 power poles0 10 20 30 40 50 60 70 80 90 100 110 120 130 140ambient temperature (°C)diagram CX 4/2 polesworking current (A)6560555045403530252015104,0 mm 2 6,0 mm 2working current (A)16 mm 2201,5 mm 2 1816141210864working current (A)500 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)200 10 20 30 40 50 60 70 80 90 100 110 120 130ambient temperature (°C)33