Proposed Fire Alarm System with Combination Smoke ... - BC Housing

Proposed Fire Alarm System with Combination Smoke ... - BC Housing

Proposed Fire Alarm System with Combination Smoke ... - BC Housing

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Generic Specification for <strong>BC</strong>H <strong>Proposed</strong> <strong>Fire</strong> <strong>Alarm</strong> <strong>System</strong> for Construction: SECTION 16000Option A – Sounder Base Releases Audible Signal <strong>with</strong>in Suite of OriginOption B – Future Provision for the Capability to Remotely Disengage Sounder Base inDesignated SuitesReference: CFT Engineering Report C5843_R01Rev01, Dated May 28, 2008 and Revised July 16, 2008,Henceforth Referred to as CFT Reportover scale measurements of the drawings.b) The electrical contractor is to be responsible for correcting all work completed contrary tothe intent of the drawings and is to bear all costs of same. Where the intent of thedrawings is not clear, obtain clarification from the engineer before proceeding <strong>with</strong> thework.c) It is the intent of these drawings to provide for an electrical and fire alarm installationcomplete and in operating condition and the electrical contractor is to be responsible forthe supply and installation of all materials necessary to accomplish this.d) Compliance <strong>with</strong> Option AWithin each suite, the smoke/heat (rate of rise) combination detector device complete <strong>with</strong>sounder base is to be installed in accordance <strong>with</strong> the CFT Report, and appropriateCodes and Standards. Sounder base is to activate when the smoke detector portion ofthe smoke/heat (rate of rise) combination detector device (a non-latching device) isdetected <strong>with</strong>in the suite. Also, the system must have the capability of programmingindividual suites to be separately “zoned”. A separate smoke/heat (rate of rise)combination detector device alarm annunciator panel shall be mounted to indicate suitesmoke detection on a per suite basis. Location of annunciator panel to be determined by<strong>BC</strong> <strong>Housing</strong>. Upon activation of the heat detector component of the in-suite combinationdetector (a latching device), the central alarm will sound.Compliance <strong>with</strong> Option BDisengaging of sounder base only permitted <strong>with</strong> approval in writing from the local <strong>Fire</strong>Prevention Officer of the <strong>Fire</strong> Department.For the units where the sounder bases have been disengaged, these units must each stillannunciate as a separate zone on the primary annunciator panel and sound an audibletrouble alarm. In addition, for units which have an activated sounder base, the fire alarmpanel must have the capability of silencing (i.e. sounder base) on a programmed timingbasis.e) The electrical contractor is to be responsible for any damage caused by the improperlocation or carrying out of his work.f) The electrical contractor, in setting out of the work, is to make reference to the electrical,mechanical, structural, and architectural drawings and site conditions. Consult <strong>with</strong> therespective trades in setting out locations for conduit runs, fire alarm panel assemblies,etc., so that conflicts are avoided and symmetrical even spacing is maintained.g) Conduits are to be laid out to avid interference <strong>with</strong> other trades and are to maintainmaximum headroom <strong>with</strong> the minimum number of crossovers.h) <strong>Fire</strong> alarm break glasses are to be installed at not less than 1,200 mm or more than 1,400mm above the finished floor and are to be coordinated <strong>with</strong> the architectural details andare to be adjusted as necessary to coordinate <strong>with</strong> paneling, masonry course line, etc.Page 4 of 7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!