APPENDIX C.6 Vessel <strong>Vieques</strong> <strong>II</strong> Condition SurveyM/V <strong>Vieques</strong> <strong>II</strong>ON. D1041579, 695 PASSENGERSCONDITION SURVEYCS-01-March/15/2011Inspection Date: February 28, 2011Condition Survey Date: March 15, 2011Inspected by: Eng. Carlos E. ClaudioLocation: Fajardo Terminal, Playa Puerto Real, Puerto RicoBuilt: 1996LOA: 150 FT., NET/GR Ton: 61/90Hull: AluminumPropulsion/Gear: Detroit Diesel (4) 16V92TI / Twin DiscPropellers: Michigan Dyna-quad, 42” x 44”Actual Status: Out of service, Dry dock inspection expires, Aug/31/12Next Annual COI expires, due1


Index:Scope of WorkAnalysisCondition Survey Report2


Scope of Work:The purpose of this report is to present actual operating conditions ofM/V <strong>Vieques</strong> <strong>II</strong> as per owner’s instruction after a visual inspection ofon board equipment.Pictures and comments report presentation of outstanding items to becorrect in way to maintain vessel in operating conditions.Analysis and recommendations on immediate and long termsmaintenance projections included.3


Analysis:Vessel in excellent condition with just minor maintenance work to beaccomplished.Underwater cleaning is recommended to increase speed and fuel efficiency.Vessel in excellent conditions.4


Condition Survey ReportVessel: <strong>Vieques</strong> <strong>II</strong>Report Date: March 15, 2011Inspection Date: .February 28, 2011Report: Condition Survey, CS-01-March/15/2011By: Carlos E. ClaudioLocation - Fore Peak Tank:Fore Peak bilge suction valve and reach rod assembly install:Fore Peck tank missing valveLocation Void Space No. 1 (Bow Thruster):Remove water from bilges, maintain access manhole cover gasket at seat area:5


High water level alarm relocate to lower position to avoid water level reachingbow thruster electrical motor.Location Void Space No. 3 (Fire Sprinklers Tanks, Air Conditioning):Air conditioning pump overboard discharge hole thru connect nipple at stbd aft.Location – Engine Room:6


Main Engine No. 3 reinstallation:Main Engine 3Lowering EngineEngine foundationsEngines mount in really bad conditions where replacement will be required.Clean bilges from oily waste water and disposal:7


Exhaust cooling water connections leaks repair and insulation renewal:8


Packing Boxes 1, 2, 3, 4 – add packing and adjust as required.10


Packing Box No.1Packing Box No.211


Packing Box No. 3 Packing Box No. 4Main Engine No. 2 exhaust inboard flex connector leaks.Fire and Bilge pump water seals renew:12


Fire & Bilge PumpsBilge Pump sealFire Pump seal13


Fire damper maintain at test for proper operation:Fire Damper 1Damper access plate14


Fire Damper 2Damper access plateGenerator No. 2 overheated, test for proper operation.Location – Pilot House:15


Wheel loose at helm shaft, remove nut and add flat washer.Location – Underwater Hull:Clean bottom with diver of any marine growth.16