12.07.2015 Views

Int'l Package Insert - IRIS Diagnostics

Int'l Package Insert - IRIS Diagnostics

Int'l Package Insert - IRIS Diagnostics

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

iChem®VELOCITY Urine Chemistry StripsMATERIAL SAFETY DATA SHEETREF: 800-7204, 800-7204-001Conforms to OSHA and EU 91/155/CEEIris <strong>Diagnostics</strong>A Division of <strong>IRIS</strong> International, Inc.9172 Eton AvenueChatsworth, CA 91311Phone (818) 709-1244Emergency (800) 776-4747


iChem®VELOCITY Urine Chemistry StripsREF: 800-7204, 800-7204-001Conforms to OSHA and EU 91/155/CEESection 1: Company and Product IdentificationProduct Name:iChemVELOCITY StripsPart Number(s): 800-7204, 800-7204-001Manufacturer:Iris <strong>Diagnostics</strong>, a Division of <strong>IRIS</strong> International, Inc.Distributor and Emergency Phone Number:Iris <strong>Diagnostics</strong> - (800) 776-4747 or (818) 709-1244 or contact local poisoncontrol centerSection 2: Composition and Information on IngredientsHazardous Ingredients:These products are manufactured on reagent-impregnated paper that may containconstituents, which have been considered as cancer suspect agents. However, theweight percent of these within the iChemVELOCITY reagent strips are respectivelyless than 0.1% and are well below the OSHA hazard limits. Refer to 29 CFR 1910.1200Hazard Communication Standard,Composition: Bilirubin: 2,4 dichlorobenzene diazonium salt 2.9%Urobilinogen: Fluorodiazonium tetrafluoroborate 0.6%Ketones: Sodium nitroprusside 2.0%; Glycine 70.5%Ascorbic Acid: 2,6-dichloro-phenol-indophenol 0.7%Glucose: Glucose oxidase 1.8%; Peroxidase 0.9%; Tetramethylbenzidinedihydrochloride 3.5%Protein: Tetra-bromophenol blue 0.2%Blood: Cumene hydroperoxide 14.5%; Tetramethylbenzidine dihydrochloride 2.9%pH: Bromthymol blue 18.8%; Cresol red 1.2%; Methyl red 1.3%Nitrite: Sulfanilamide 3.7%; N-(naphthyl)-ethylenediammonium dihydrochloride 0.3%Leukocytes: Indoxylcarbonic acid ester 0.4%; Diazonium salt 0.2%Specific Gravity: Bromthymol blue 4.6%Section 3: Hazards IdentificationPhysical Hazards:May be harmful if ingested. May cause eye and skin irritation.Potential Health Effects Summary:Does not meet EU, OSHA or WHMIS criteria for hazardous materials.Product HazardClassifications:EU: Not listed WHMIS: Exempt US OSHA: Not listedSection 4: First Aid MeasuresIngestion:Eye Contact:Skin Contact:Rinse mouth, give copious amounts of water to dilute the substance, Nevergive anything by mouth to an unconscious person. Immediate medical attentionis required.If product is splashed in eyes, wash eyes under gently running water for atleast 15 minutes, making sure that the eyelids are held open. If irritation orredness develops, obtain medical attention.Immediately wash thoroughly with soap and water. Immediately seek medicaladvice if it causes itchiness and inflammation etc.1


iChem®VELOCITY Urine Chemistry StripsSection 5: Fire Fighting MeasuresFlash Point:Flammable LimitsAuto-ignition Temperature:Extinguishing Media:Special Fire and Explosion Hazards:Hazardous Combustion Products:Protective Equipment for Firefighters:N/AN/AN/AUse extinguishing media suitable for surrounding fire.NoneNoneNoneSection 6: Accidental Release MeasuresPersonal Precautions:Spill and Leak Procedures:Environmental Precautions:Avoid skin and eye contact; use good laboratory practices.No special hazards determined.Absorb into inert solid or dilute with a large quantity of water and flush intoan approved wastewater treatment system. Comply with all applicable legalregulations.Section 7: Handling and StorageHandling Precautions:Recommended Storage Conditions:Other Precautions/Special Hazards:Use good laboratory practices; avoid eye and skin contact.To maintain efficacy, store according to the instructions on the productlabeling.None.Section 8: Exposure Controls and Personal ProtectionEXPOSURE LIMITSUS OSHA:ACGIH:DFG MAK:Engineering Controls:Eye Protection:Skin Protection:None established.None established.None established.Use in well ventilated area.Safety glasses should be worn to prevent eye contact.Impervious gloves should be worn to prevent skin contact.Section 9: Physical and Chemical PropertiesPhysical State:This is a dry reagent strip and consists of a plastic strip affixed withreagent areas.Section 10: Stability and ReactivityStability:Hazardous Incompatibilities:Hazardous Decomposition Products:Stable under normal temperatures and pressures.U/ANot available2


iChem®VELOCITY Urine Chemistry StripsSection 11: Toxicological informationToxicity Data for Hazardous Ingredients:Primary Routes of Exposure:Potential Effects of Acute Exposure:Potential Effects of Chronic Exposure:Symptoms of Overexposure:Carcinogenicity:Other Effects:N/ASkin or eye contact.None identified.None identified.No specific symptoms identified.No ingredients in this product are listed as carcinogens by ACGIH, IARC, NTP,OSHA or 67/548/EEC Annex I.None identified.Section 12: Ecological informationEcotoxicity:Biodegradability:Mobility:No results of ecological studies are available.No results of biodegradability studies are available.No results of mobility studies are available.Section 13: Disposal ConsiderationsWaste Disposal:Dispose of used strips as biohazardous waste in accordance with all applicableregulations. Any disposal practice must be in compliance with company,local, state and federal laws and regulations. (Contact country, local or stateenvironmental agency for specific rules.)Section 14: Transport InformationTransportation of this product is not regulated under ICAO, IATA, US DOT, European ADR/RVD, or Canadian TDG.Section 15: Regulatory InformationUS Federal and State Regulations This product is not classified as a dangerous preparation according to 1999/45/EC and 67/548/EEC and 2001/58/EC.Section 16: Other InformationFor further information, please contact Iris <strong>Diagnostics</strong>N/A = Not ApplicableU/A = UnavailableA Division of <strong>IRIS</strong> International, Inc.9172 Eton AvenueChatsworth, CA 91311Phone 1.818.709.1244U.S. Toll Free 1.800.776.4747© Copyright 2012 Iris <strong>Diagnostics</strong>. All rights reserved.300-8032 CThe above information is believed to be accurate and represents the best informationcurrently available to us. However, Iris <strong>Diagnostics</strong> makes no representation as to itscomprehensiveness or accuracy. It should be used only as a guide and as a supplementto information concerning this product available from other sources. Individuals mustexercise their independent judgment and make their own investigations in determiningthe suitability of this information for a particular purpose. Iris <strong>Diagnostics</strong> makes no warrantyof merchantability or any other warranty, expressed or implied, with respect to theinformation set forth herein or to which the information refers. Iris <strong>Diagnostics</strong> will notbe responsible for damages resulting from the use of or reliance upon this information.Disposal of hazardous materials may be subject to local laws or regulations.iChem ® VELOCITYIS A REGISTERED TRADEMARK OF <strong>IRIS</strong> INTERNATIONAL INC.11/8/2012

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!