12.07.2015 Views

Software-Update Version 1.0.10 manual In order to keep your door ...

Software-Update Version 1.0.10 manual In order to keep your door ...

Software-Update Version 1.0.10 manual In order to keep your door ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

KTC-2 (MS9)The following chart shows the setting entries:The standard values are shown here, they may however vary.ParametersParameterdesignationSymbolDescription Unit Range OriginalsettingPalmCentral systemLearning cycleOriginal settingWiringCurrent errorstatusError list - - - - -Door diameter Door diameter mm 2000 .. 6500 (systemlearnsdiameter)#el. lockingdevicesElectromechanical bolt lockingdevice no = 0, yes = 1- - C - -0 .. 1 0 U U - C -Hold after s<strong>to</strong>p#X-Pos Au<strong>to</strong>1 - 2Time until the el. brake isreleased after an EmergencyS<strong>to</strong>p0 = brake never released, 1 - 9= after... sec.Number of starting positions inAu<strong>to</strong>matic 1 or 2sec (0 .. 9) sec 1 U U - C -2 .. 5 2 U U - C -SlowS<strong>to</strong>p canopySlowS<strong>to</strong>p time of canopyintegratedsensorssec(0 .. 15) sec16 = ∞16 U U - C -SlowS<strong>to</strong>p wing SlowS<strong>to</strong>p time of wing sensor 0.1sec(0 .. 15.9) sec16.0 = ∞16.0 U U - C -Hold after s<strong>to</strong>pTime until the <strong>door</strong> starts after asafety s<strong>to</strong>p0.1sec(0 .. 9.9) sec 1.0 U U - C -Sec. area s<strong>to</strong>pSummerconfigurationStarting positionSummerDetection range of canopyintegratedsensor in securityarea for SlowS<strong>to</strong>pStarting-positions: 0°/180°Starting-positions: 90°/270° [0],60°/240° [1]mm(d * (pi/3).. 500) mm700 U U - C -(systemreads X-positions)- - - - U0 .. 1 0 U U - C -PosV after safetys<strong>to</strong>pA/M lightingTime system operates inpositioning speed after leavingthe stationary position followinga safety s<strong>to</strong>pAu<strong>to</strong>matic/<strong>manual</strong> lightingcontrol0.1sec(0.0 .. 2.9) sec 1.0 U U - C -0 ... 1 0 (au<strong>to</strong>) U U - C -FUT warm aircurtainFollow-up time of warm aircurtainsec 0 ... 600 10 U U - C -Caption:U = adjustable valueC = resettable value- = non-adjustable valueStand 08.02.2012Technische Änderungen vorbehalten<strong>Software</strong>-<strong>Update</strong>_Ver1010_GB.doc DORMA KT-Systeme Seite 3 von 14

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!