12.07.2015 Views

In-service safety inspection and testing of electrical equipment

In-service safety inspection and testing of electrical equipment

In-service safety inspection and testing of electrical equipment

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1.3 INTERPRETATION1.3.1The terms ‘normative’ <strong>and</strong> ‘informative’ have been used in this St<strong>and</strong>ard to define the application <strong>of</strong> theappendix to which they apply. A ‘normative’ appendix is an integral part <strong>of</strong> a St<strong>and</strong>ard <strong>and</strong> subject to thesame level <strong>of</strong> compliance as if it were in the body <strong>of</strong> the St<strong>and</strong>ard, whereas an ‘informative’ appendix isprovided for information <strong>and</strong> guidance, <strong>and</strong> may indicate good practice. Non-compliance with aninformative appendix will not be seen as non-compliance with the St<strong>and</strong>ard.1.3.2 Shall <strong>In</strong>dicates a statement is m<strong>and</strong>atory to achieve compliance with this St<strong>and</strong>ard.1.3.3 Should <strong>In</strong>dicates a statement is preferred as indicating good practice, but is not m<strong>and</strong>atory.1.3.4 May <strong>In</strong>dicates the existence <strong>of</strong> an option.1.3.5 Clause references are provided without prefix as the clause number only, for example 2.3.21.4 DEFINITIONSFor the purpose <strong>of</strong> this St<strong>and</strong>ard, the following definitions shall apply:1.4.1 Accessible earthed parts(a)Accessible earthed parts are a conductive part <strong>of</strong> <strong>electrical</strong> <strong>equipment</strong>, required to be connected toa protective earth, which:(i)(ii)(iii)Are separated from live parts by basic insulationCan be touched with the jointed test finger as specified in AS 60529, <strong>and</strong>Are not a live part but can become live if basic insulation fails.(b)The term accessible earthed parts does not apply to the following:(i)(ii)Parts separated from live parts by double insulation or reinforced insulation, or by othermetal parts themselves earthed or having double insulation or reinforced insulationMetal nameplates, screwheads, covers or plates, <strong>and</strong> their means <strong>of</strong> fixing, which cannotbecome live in the event <strong>of</strong> failure <strong>of</strong> insulation <strong>of</strong> live parts, or be exposed to arcing contactwith live partsNOTE — ‘Failure <strong>of</strong> insulation’ in this context is taken to include accidental bridging <strong>of</strong> an insulatinggap by metal, or partially conducting material, such as carbon dust or moisture, as well as <strong>electrical</strong>breakdown.(iii)Parts within an enclosure, the cover <strong>of</strong> which requires the use <strong>of</strong> a tool for its removalNOTE — A key is not considered to be a tool except where special circumstances prevail, for example,the use <strong>of</strong> the key is restricted to technical <strong>service</strong> personnel having an appropriate level <strong>of</strong>electrotechnical training.(iv)Parts within <strong>equipment</strong>, the configuration <strong>and</strong> mass <strong>of</strong> which are such that the parts are notaccessible during normal use <strong>and</strong> movement <strong>of</strong> the <strong>equipment</strong>.NOTE — Non-metallic material that is conductive to a degree, <strong>and</strong> may contribute to a hazardouscondition arising shall be deemed to be an accessible earthed part, subject to the above provisions.1.4.2 Accessible unearthed partsAccessible unearthed parts are all external parts that are not connected to the protective earthingconductor <strong>and</strong> are separated from live parts by double insulation or reinforced insulation, <strong>and</strong> includesparts used to support the <strong>equipment</strong> in operation.1.4.3 Class I <strong>equipment</strong> (basic insulated, protectively earthed <strong>equipment</strong>)Equipment in which protection against electric shock does not rely on basic insulation only, but whichincludes an additional level <strong>of</strong> protection, in that conductive accessible parts are connected to the7 <strong>of</strong> 46

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!