12.07.2015 Views

Lochinvar - API of NH

Lochinvar - API of NH

Lochinvar - API of NH

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Designer’s Guide / Knight XL BoilerLOCHINVAR CORPORATION300 MADDOX SIMPSON PKWYLEBANON, TN 37090www.lochinvar.comSystem Supply SensorA sensor to be mounted in the supply line <strong>of</strong> the primary system loop. When the SmartSystem is programmed to operate <strong>of</strong>f the outlet sensor (default setting), and the systemsupply sensor is connected, it will control the firing rate based on this sensor. Thissensor should always be installed, even when inlet temperature control is programmedfor control.Outdoor Air Reset with Outdoor SensorA sensor mounted outside the building. The Smart System control will adjust systemtemperature based on this sensor.TipDRAW THE SENSORS AND THE SENSOR LOCATIONS INTO YOUR BUILDING AND PIPING PLANS.SMART SYSTEM OPERATIONAL FEATURESThe following is a list <strong>of</strong> just a few <strong>of</strong> the many other operational features built-in to the SmartSystem control. For the complete list <strong>of</strong> features with more detailed explanations plusprogramming parameters, refer to the Installation & Operation Manual, the Service Manual or theUser Manual.ClockThe Smart System has a clock for date and time. This must be set for record keepingand night setback functions.DHW PriorityOn a DHW call for heat, the Smart System control will interrupt a Space Heating call forheat, switching <strong>of</strong>f the boiler pump and turning on the DHW pump.Freeze ProtectionThe Smart System control automatically monitors the water temperatures and willoperate the pump and if necessary, fire the appliance to protect the heat exchanger fromfreezing.Anti-CyclingThe Smart System control will monitor burn cycles and force a minimum <strong>of</strong>f time toreduce short cycling.Night SetbackThe Smart System will reduce the Space Heating or DHW setpoints during periods wherethe building is unoccupied. This is a programmable parameter.Service ReminderThe Smart System control can display a reminder to the customer that it is time for aservice call. This time frame is a programmable parameter.AND MOREOpen / Shorted Sensor DetectionFan Speed Low & Fan Speed HighFlame Current SupportFlue Temperature LimitingOutlet Temperature LimitingDHW versus SH CyclingLow Voltage BlockingMonitoring <strong>of</strong> Safety DevicesRamp DelayRun Time and Cycle CountTemperature Rise LimitingGradient LimitingHigh Limit OperationLow Water Cut<strong>of</strong>f Protection26

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!