12.07.2015 Views

Mn/DOT SD-15 April 2, 2012 Schedule of Materials Control P a g e 1 ...

Mn/DOT SD-15 April 2, 2012 Schedule of Materials Control P a g e 1 ...

Mn/DOT SD-15 April 2, 2012 Schedule of Materials Control P a g e 1 ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Mn</strong>/<strong>DOT</strong> <strong>SD</strong>-<strong>15</strong> <strong>April</strong> 2, <strong>2012</strong> <strong>Schedule</strong> <strong>of</strong> <strong>Materials</strong> <strong>Control</strong> P a g e 44VII. Metallic <strong>Materials</strong> and Metal Products (cont.)PayItemNo.25452554256425542557Kind <strong>of</strong> MaterialSpec.No.Minimum RequiredAcceptance Testing(Field Testing Rate)2. Steel Sign Posts 3401 Visual Inspection &Certification from Contractor <strong>of</strong>compliance with Domesticsource requirement under 1601,if applicable.3.Posts for Traffic & FenceA. Steel fence posts, brace bars,and rails2557 3. FenceB. Components: includescup, cap, nut, bolt, end clamp,tension band, truss rodtightener, hog ring, tie wire,tension stretcher bar, trussrod, clamp, & tension wire34033406Visual InspectionMinimum RequiredSampling Rate forLaboratory TestingTwo posts per shipment <strong>of</strong>each mass per unit length.Submit shortest full sizedlength <strong>of</strong> each weight, not ascrap piece.One sample per 500 pieces.Submit full length for postsused in the ground (line,terminal, "C" and anchorposts), and 5' length <strong>of</strong> top railand brace bar.3376 Visual Inspection 1 each <strong>of</strong> cup, cap, nut, bolt,end clamp, tension bands,truss rod tightener, 12 hogrings, 6 tie wires, 1 tensionstretcher bar; 1 truss rod, cutto 2-foot min. with threadedsection, 3 feet <strong>of</strong> tensionwire.SampleSizeSeenoteNotesForm 024<strong>15</strong> or 2403Check domestic steel requirement under 1601Form 024<strong>15</strong> or 2403Check domestic steel requirement under 1601Special Provision. Retain Certificate <strong>of</strong>Compliance and certified mill analysis in projectfile.See link for certification form on right side <strong>of</strong>page, www.dot.state.mn.us/materials/lab.htmlForm 024<strong>15</strong> or 2403Check domestic steel requirement under 1601Special Provision. Retain Certificate <strong>of</strong>Compliance in the project file.See link for certification form on right side <strong>of</strong>page, www.dot.state.mn.us/materials/lab.html2557 1. 3. FenceC. Gates3379 Visual Inspection No sample required. Seenotes.Form 024<strong>15</strong> or 2403Check domestic steel requirement under 1601Special Provision. Retain Certificate <strong>of</strong>Compliance in the project file.See link for certification form on right side <strong>of</strong>page,www.dot.state.mn.us/materials/lab.html2557 3. FenceD. Barbed Wire3376 Visual Inspection. One full height sample per 50rolls1 m(3 ft)Form 024<strong>15</strong> or 2403Check domestic steel requirement under 1601Special Provision. Retain Certificate <strong>of</strong>Compliance in the project file.See link for cert. form on right side <strong>of</strong> page,www.dot.state.mn.us/materials/lab.html

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!