at meets the<br />

economical demands.<br />

ity and facilitates thermal bridge free<br />

construction. Wood is therefore the<br />

preferred material for building passive<br />

houses. For the Christophorus<br />

House, wood was combined with<br />

high-quality insulation materials,<br />

resulting in a thermal bridge free<br />

construction of highest airtightness<br />

and excellent passive house values.<br />

The energy supply:<br />

sustainable and costeffective.<br />

Eight Duplex geothermal probes of<br />

100 m length are used to exploit the<br />

earth – both as a heat source and a<br />

heat sink – for this building. During<br />

the heating period, the heat pump<br />

supplies the building with additional<br />

warmth via the deep probes. In<br />

summer, the same system is used for<br />

cooling – with a minimum consumption<br />

of energy. Distribution of the<br />

cooling resp. heating medium in the<br />

house is done via 560 m2 of heating/cooling<br />

ceilings and floor elements.<br />

An on-grid photovoltaic system<br />

with a peak output of 9.8 kW<br />

ensures that the power needed for<br />

the heat pump resp. for operating<br />

pumps and fans is largely supplied<br />

in a CO2-neutral way.<br />

The water concept:<br />

self-cleaning and<br />

economical.<br />

The entire amount of greywater and<br />

rainwater is cleaned with the help of<br />

three biological sewage treatment<br />

plants and recycled as service water<br />

for flushing toilets, irrigating plants<br />

and washing cars. In this way, the<br />

consumption of potable water is<br />

reduced to a minimum. Nearly 70 %<br />

of the required hot water is generated<br />

by the thermal solar system.<br />

Annual space heating requirement (HWB)<br />

acc. to PHPP: 14.00 kWh/m2a Heating demand acc. to PHPP: 14.00 W/m 2<br />

Pressure test n50: 0.40 1/h<br />

U-values of structural components:<br />

External wall: 0.11 W/m 2 K Roof: 0.11 W/m 2 K<br />

Cellar ceiling/floor: 0.13 W/m 2 K Glazing: 0.70 W/m 2 K<br />

Uw total window: 0.79 W/m 2 K Acc. to PHI Certificate<br />

The bottom line:<br />

exemplary.<br />

Compared to a conventional office<br />

building, the Christophorus House<br />

realizes primary energy savings of<br />

approx. 275,000 kWh/a (average).<br />

Heating and cooling is largely done<br />

in a CO2-neutral way. Yearly reduction:<br />

75 tons of CO2 compared with<br />

conventional construction. All this is<br />

achieved while providing a most<br />

comfortable indoor climate: about<br />

40-50 % air humidity and temperatures<br />

of 21-23°C.<br />

Planning: Dipl. Ing. Albert P. Böhm<br />

and Mag. Helmut Frohnwieser<br />

Developer: BBM (Procurement<br />

Services of the MIVA). Contact:<br />

Franz X. Kumpfmüller<br />