12.07.2015 Views

Air-to-water reversible heat pumps - Euroconfort

Air-to-water reversible heat pumps - Euroconfort

Air-to-water reversible heat pumps - Euroconfort

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

QUICK SELECTION<strong>Air</strong>-<strong>to</strong>-<strong>water</strong> <strong>reversible</strong> <strong>heat</strong> <strong>pumps</strong>AQUALIS INVERTERAQUALIS INVERTER33H44HMinimum Nominal Maximum Minimum Nominal MaximumHeating capacity +7°C 5.3 10.2 11.9 5.3 12.2 14.535°CCOP 3.79 4 3.72 3.53 3.81 3.92Heating capacity -7°C 3.5 6.6 10.5 3.3 7.3 11.4COP 2.7 2.68 2.28 2.36 2.32 2.11Heating capacity +7°C 4.9 9.9 10.2 5.1 11.4 12.445°CCOP 3.07 3.14 2.68 3 3.04 2.76Heating capacity -7°C 3.3 6.3 10.3 3.1 7.2 10.6COP 2.1 2.1 1.87 1.83 2.03 1.63Heating capacity +7°C 4.7 9.3 10.54 4.8 10.7 12.655°CCOP 2.47 2.48 2.33 2.4 2.35 2.38Heating capacity -7°C 3.1 6.4 9 2.9 6.5 9.3COP 1.72 1.94 1.3 1.53 1.76 1.13Energy rating A BSupply voltage230 V - 1 - 50 HzSound level dB(A) (1) 37 46 47 37 48 49(1) 5 m from unit, 1.5 m from floor, directivity 2 ± 3 dBA at 10°CCOMPOSITIONHermetic compressor- DC INVERTER rotary scroll compressor. Two scrolls (onefixed and one orbiting).- Built-in electric mo<strong>to</strong>r cooled by suction gas.- Mo<strong>to</strong>r protected by internal winding sensor.- Noise insulation.Water-<strong>to</strong>-refrigerant <strong>heat</strong> exchangers- Brazed plates.- AISI 316 stainless steel intermediate and end plates.- High-performance, optimised plate patterns.- Thermal insulation.<strong>Air</strong>-cooled <strong>heat</strong> exchanger- Bent coil, copper tubes and aluminium fins.Standard components- Reversing valve.- Suction accumula<strong>to</strong>r.- Liquid tank.- Electronic expansion valve.- Dryer.- Crankcase <strong>heat</strong>er.Electrical panel- Box conforms <strong>to</strong> EN 60335 standard.- Main earth connection.- Electronic control unit with microprocessor:· Uses a <strong>water</strong> law <strong>to</strong> adjust the hot <strong>water</strong> or chilled <strong>water</strong>temperature based on the outdoor temperature.· Boiler backup mode: au<strong>to</strong>matically runs the <strong>heat</strong> pump andboiler, either alternately or simultaneously, using a setting thatcan be adjusted based on the outdoor temperature.· Moni<strong>to</strong>rs the operating and safety settings.· Displays the temperatures on the terminal.· <strong>Air</strong> setpoints in comfort unit and RFHC mode.· Controls the unit.· Two-wire remote-control terminal. ON/OFF input control (twoinputs, au<strong>to</strong>matic/load shedding, <strong>heat</strong>ing - cooling/absence).- 5-minute short-cycle protection.- Optimised defrosting.Control and safety unit- High-pressure safety switch.- Pressure sensors (HP/LP).- Two frost sensors (exchanger <strong>water</strong> outlet and exchangerrefrigerant outlet).- Water sensors on exchanger <strong>water</strong> inlet and outlet.- Coil sensor.- Outdoor sensor.- Suction sensor.Built-in hydraulic module- Safety valve set at 4 bar.- Manual air bleed valve.- Multispeed circula<strong>to</strong>r.- Differential <strong>water</strong> pressure switch.Accessories (option) (for installation on site)- Insulated hose assemblies.- Anti-vibration mounts.- Screen filter with ball valve kit.- Filling kit.- Loop <strong>heat</strong>er.2AIR CONDITIONING - HEATING - REFRIGERATION - AIR HANDLING - HEAT EXCHANGE – NA 09.669 B

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!