12.07.2015 Views

Why OCTAX Laser shot

Why OCTAX Laser shot

Why OCTAX Laser shot

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Laser</strong> ShotSystem for ARTBased on the scientificwork of specialists atEPFL and CHUVLausanne the mostadvanced 1.48 μminfrared diode lasershave been developed.<strong>Laser</strong>s using thistechnology presentlyare the most widelyused systems in theworld with the largestnumber of installationsand treatments.EyeWareImaging SoftwareThe <strong>OCTAX</strong> <strong>Laser</strong> Shotis the first digitallycontrolled laser systemincluding <strong>OCTAX</strong>EyeWare imagingsoftware for digitalimage or video processingalso offeringa large number ofadvanced features.Ref.No. 19310/0148Components• <strong>OCTAX</strong> <strong>Laser</strong> Shotmodule• <strong>OCTAX</strong> EyeWareBASIC• <strong>OCTAX</strong> <strong>Laser</strong> Lens• <strong>OCTAX</strong> Eye USBcamera• ComputerCost for <strong>OCTAX</strong> systemcompatible computersare not included in<strong>OCTAX</strong> system pricing.Software specificationComputer hardware: Intel Processor based, 2,8 GHz,Microsoft® Windows 7/Vista/XP<strong>Laser</strong> targeting: Live video display with crosshairand measurement grid overlayMeasurement: Direct calibration and directinteractive measurementImaging software: Image archival includingmeasurement locationsImage database: Access to image data viadatabase organized per patient and treatmentpolarAIDEAutomatic assessment of oocyte quality and beyond<strong>OCTAX</strong> polarAIDE is the next generation integrated polarization microscopy system based on<strong>OCTAX</strong> ICSI Guard technology*.Take advantage of <strong>OCTAX</strong>´s modular high endtechnology for evaluating your oocytes:<strong>OCTAX</strong> polarAIDE TM is available as stand-alonesystem, as an upgrade to <strong>OCTAX</strong> ICSI Guard TMor as an add-on to <strong>OCTAX</strong> <strong>Laser</strong> Shot TM systems.All functions are handled by one easy-to-usesoftware: <strong>OCTAX</strong> EyeWare TM is the uniqueplatform for the control of all <strong>OCTAX</strong> products:laser, polarization microscopy, image processing,data storage and motorized stage.Main Features• Quantification of the birefringence of the zona pellucida• Automatic scoring of the developmental potential of oocytes in seconds• Orientation-independent live imaging of the meiotic spindle• Simultaneous view of oocyte morphology and spindle• Self-calibrating, no active calibration required• One button instant on/off function for convenient use• Spindle imaging under normal light intensity (bright field)• Full <strong>OCTAX</strong> <strong>Laser</strong> Shot TM and Fertilase® compatibility, i.e. one camera, one software and onedatabase for laser control, spindle visualization and image processing• Support of all <strong>OCTAX</strong> EyeWare TM features (image acquisition and archival, video and time lapsevideo recording, biometric measurements etc.)<strong>Laser</strong> module specification<strong>Laser</strong>: 1.48 μm Infrared Diode <strong>Laser</strong> class 1MPower in Focus: 90-130 mW +/-5 %(depending on the microscope model)Irradiation time: 0.1-10.0 ms, in 0.1 ms stepsDrilling precision: < 1 μmDrilling reproducibility: < 1 μmDrilling range with one <strong>shot</strong>: ~ 1 μm to ~ 25 μm(depending on the zona pellucida characteristics)Beam position stability: < 5 μm per month<strong>OCTAX</strong> USB 2.0 cameraResolution: 1280 x 1024 pixelFrame rate: up to 30 fps<strong>OCTAX</strong> <strong>Laser</strong> Shot system has received 510(k) clearance by the FDA/USA for <strong>Laser</strong> Assisted HatchingMetaphase II oocyte, polarAIDE TM in bright fieldoptics.Metaphase II oocyte, polarAIDE TM active, combinedmode using red/green processed image. Red areaindicates high birefringence.Metaphase II oocyte, polarAIDE TM active scoringmode. Pink area indicates high birefringence.Colour-coded numerical score for oocyte qualityis displayed automatically.System Components• Circular polarizer and GIF filter• Liquid crystal analysis slider• High resolution <strong>OCTAX</strong> USB 2.0 digital camera• <strong>OCTAX</strong> polarAIDE TM softwarepolarAIDE TM is currently available for• Nikon Ti, TE2000, TE200/300, Diaphot 200/300• Olympus IX 50/70 and IX 51/71• Zeiss Axio Observer, Axiovert 200, 135, 100• Leica DMIRB, DMI 4000, DMI 6000• other microscopes on requestFor operating <strong>OCTAX</strong> polarAIDE TM , oocytes have to be placed in glass bottom dishes instead of plastic dishes. A heated stage is mandatory to maintain optimumtemperature. <strong>OCTAX</strong> polarAIDE TM supports high resolution live video display (1280x1024 pixel) on selected computer hardware.* Patents pending. polarAIDE TM is currently not available in U.S.A.Photo courtesy CHUV, Lausanne, Switzerland20 21


cytoScreenAffordable IMSI through digital image enhancementVibration Free Microscopic Table• Compatible with your existing Hoffman ICSI microscope• Computer-enhanced high-magnification microscopy for morphology based sperm selection• No oil immersion, no DIC – practicable for your existing workflow• Cost effective integration into your existing <strong>OCTAX</strong> environment (camera, EyeWare imaging software)• Total magnification adjustable, up to 7,200 x• Use your existing <strong>OCTAX</strong> laser for convenient sperm immobilizationI. System componentsCondenserObjectiveCameraSoftwareExisting Hoffman´s or relief contrastCost saving solution, condenser supports all potential applications60 xLarge field of view allows sperm immobilization without changingmagnification1.3 or 3.0 MegapixelII. Features and performanceImage database, one button image capture, biometric measurement tools,one button online zoom-in function, adjustable image enhancement<strong>OCTAX</strong> polarAIDE TM spindle and zona imaging system and <strong>OCTAX</strong> <strong>Laser</strong>Shot TM microsurgical laser can be integrated into the same softwareenvironmentVibration free table – speciallydeveloped for micromanipulationin IVF labsFour vibration dampers with combinedrubber metal connection and hydraulicbearingSlabMaterial:Dimensions:FrameMaterial:Height:Weight:polished granite120 x 70 x 10 cm(standard),special sizes and wallmounted versions areavailable on requestStainless steel77 - 82 cm, adjustableapprox. 300 kgRef.No. 22047/0000Oil immersionNoEasy handling, no cleaning, works with or without heated glass plateSharpness of the imageTotal magnificationon the screenAnalysis of spermhead shape and vacuolesDishes requiredCompatibilityGood (limited by the physical characteristics of the 60 x objective)improved through digital image processing of the live video> 10,000 x with intermediate magnification 1.6 xFor practical reasons, the optimum range of magnification is between5,000 x and 7,000 xFeasible without restrictionsGlass bottom dishesCan be mounted to most current inverted microscope models used for ICSI22 23


<strong>Why</strong> <strong>OCTAX</strong> <strong>Laser</strong> <strong>shot</strong> TM systems? Unique features of <strong>OCTAX</strong>1. Low power laser system of proven safety in clinical application<strong>OCTAX</strong> TM (the advanced version of Fertilase R ) is absolutely unmatched with regard to its scientificbackground and the safety testing for clinical application. There are more than 70 original paperspublished on the use of Fertilase R / <strong>OCTAX</strong> TM . Almost all scientific papers describing the use of a 1.48µm laser are based on either Fertilase R or <strong>OCTAX</strong> TM and, as a matter of fact, based on a laser withlow power in focus of 100 to 150 mW.Our system is the only laser on which basic safety studies have been done. All fundamentalsafety studies regarding the use of a 1.48 µm laser in ART are based on Fertilase R laser. Theyinvolved histological as well as genetic and scanning electron microscope (SEM) analyses. <strong>OCTAX</strong> TMis the digital version of Fertilase R . Without changing the core settings, <strong>OCTAX</strong> is manufactured anddeveloped by the same scientists as Fertilase R . Hence, the <strong>OCTAX</strong> TM concept combines latesttechnology with continuity and proven safety.Competitors are using higher laser power (300 – 400 mW) and different techniques. They do notclearly indicate the power in focus which is the only relevant parameter for clinical application,because the power of the laser diode will be modified according to optical conditions, to the type ofplastic dishes, the volume of culture media etc. It is too simple to conclude that basic test results withFertilase R / <strong>OCTAX</strong> TM technology are valid for other laser systems which have been continuouslyincreasing laser power. Higher power will lead to higher peak temperatures which cannot becompensated for by just reducing pulse length.The only published follow-up study is based on Fertilase R laser technology: Kanyó K., Konc J.(2001) Follow-up study after non-contact laser hatching. IFFS Melbourne, Abstract Book, p. 49 (posterpresentation). Infertility Center of Buda, St. János Hospital, 1. Diösärok, Budapest, Hungary, 1125.There are around 15,000 babies born after application of Fertilase R / <strong>OCTAX</strong> TM without any adverseeffect being documented. So why take any risk if you could be on the safe side with the wellestablishedmarket leader using a system of proven safety?2. ReliabilityFertilase R / <strong>OCTAX</strong> TM <strong>Laser</strong> <strong>shot</strong> systems are the most used and best known systems worldwide.During the last 10 years, more than 300 systems have been installed worldwide without anyproblems occurring. Many leading IVF centers, researchers and pioneers in IVF are working with oursystem. Just a few examples:• Centro IVI Valencia, Valencia, Spain (Prof. A. Pellicer Martínez)• Department of Gynecological Endocrinology and Reproductive Medicine, University of Bonn,Germany (Dr. M. Montag, Prof. van der Ven; 2 systems)• Free University of Brussels, Belgium (Prof. Van Steirteghem, Prof. Devroy; 2 systems)• Hôpital Antoine Béclère, Clamart, France (Dr. R. Fanchin)• Kato Ladies Clinic, Tokyo, Japan• Obstetrics and Gynecology Hospital, Chongquing, China (Dr. Huang)• Reproductive Biology Associates, Atlanta, USA (Z.P. Nagy, MD, PhD),• Sydney IVF, Sydney, Australia (Dr. J. Catt)• The Egyptian IVF-ET Centre, Cairo, Egypt (Prof. Aboulghar, Prof. Mansour)


<strong>OCTAX</strong> TM laser <strong>shot</strong> system is a maintenance free system. There are no parts to be replaced inspecific intervals nor movable parts prone to disturbances. If necessary, cleaning of opticalcomponents can be done by our local distributors as well as by technicians of microscopemanufacturers. System updates will be provided within short response times by technicians from MTGMedical Technology Vertriebs-GmbH, Germany.3. Unmatched image quality<strong>OCTAX</strong> <strong>Laser</strong> Shot TM is using the latest imaging and computer technologies. It is the only laser <strong>shot</strong>system working with digital instead of analogue cameras. The system excels through outstandingimage quality (see our brochures; all images taken with <strong>OCTAX</strong> USB camera on a Nikon TE2000inverted microscope). Only <strong>OCTAX</strong> is offering two high quality laser objectives (25 x, 40 x) fittingany demands. The objectives support Hoffman´s Modulation Contrast as well as Zeiss PlasDICfor high quality images and live video.4. Advanced features of the <strong>OCTAX</strong> “all in one” systemThe <strong>OCTAX</strong> TM system only needs one USB 2 camera and the EyeWare TM image processing anddatabase software for controlling the laser <strong>shot</strong> system, archiving images and videos, visualizingmeiotic spindles and even for controlling the <strong>OCTAX</strong> TM motorized and heated microscope stages.There are no additional controllers needed.<strong>OCTAX</strong> EyeWare TM is the only system coming with a microsurgical laser which offers in one system• online Web access to patient database, images and video files• unlimited number of images stored in patient database• multi-language software editions: English, German, Chinese, Japanese (additional languages inpreparation)• digital video recording / time lapse video recording without any limit in duration / file size• image capturing from any video source (analogue and digital)• energy guard TM safety system for laser application• the potential to fully integrate the <strong>OCTAX</strong> polarAIDE TM spindle imaging software at any time5. <strong>OCTAX</strong> TM has the experience and know-how – through pioneering work‣ first birth after laser assisted hatching (1.48 µm)‣ first birth after laser assisted blastomere biopsy and PGD‣ first birth after laser assisted polar body biopsy‣ first birth after laser assisted immobilization of spermatozoa (an application to avoid the use ofPVP with ICSI)‣ first pregnancy after laser assisted zona drilling for ICSI‣ first ongoing pregnancy after laser assisted removal of necrotic blastomeres from frozen-thawedembryosSummaryIn summary, the <strong>OCTAX</strong> <strong>Laser</strong> <strong>shot</strong> system TM for ART was developed by the leading scientistsin this field, based on the longest experience with microsurgical laser technology. It wasintroduced into clinical routine and tested to guarantee optimal safety in close cooperationwith embryologists all over the world. A network of disciplines complementing each otherenables <strong>OCTAX</strong> to continuously improve the laser <strong>shot</strong> system and convert trend-setting ideasinto practical application. Fertilase R and its successor <strong>OCTAX</strong> laser <strong>shot</strong> system TM is theoriginal and the gold standard in ART laser technology.TM – Safety – Experience – Precision

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!