ivf workstations - G603Microscope, light source and camerasMost microscopes can be integrated into the G603. Also modelswith ergo tubes can be integrated.The unit is delivered with the K-SYSTEMS LS12 light source withintegrated light intensity control using the main keyboard.PT-100 temperature sensorEnlarged top front window for maximum comfortG603 has been made with an extra large hole covered by a specialair tight fabric.The enlarged hole for microscope oculars allow the user to movethe microscope and the oculars in the desired positioning and givesexcellent fit for any user and supports larger microscopes.Digital interface supporting wide range of camerasThe G603 supports the new camera interfaces available in themarket such as USB, Firewire or HDMI. Analogue interface is alsoavailable.Innerwall G603Depending on the type of the microscope camera, one of the abovementionedconnectors can be incorporated.External Quality ControlFor improved external quality control – it is possible to do externalmeasurements of CO 2 and Temperature. No disassembling of theunit will be required since a special opening has been made on theback of the G603 for reaching this sensor without any tools. Thehole is blinded with a removable plastic insert. The sensor can easilybe connected / removed due to calibration purposes.External CO 2 Vaisala sensor (option)• For quality control to comply with new EU regulations• To be connected to handheld CO 2 monitor or central monitoringsystemExternal temperature sensor (option)• To detect temperature fluctuations• For improved temperature control• Prepared for pin sensor PT100 element or othersBackwall G603Easy access for CO2 andtemperature sensorwww.k-systems.dk 9


ivf workstations - G603Technical Specifications on G603OrderCode 25000Overall dimensions (WxDxH):940x830x1720mmTabletop (WxD):940x500 mmWeight112 kgMax load on overall working area:10 kgGas and Temperature AccuracyTemperature Accuracy (table top)Better than ±0.25°C of deviationCO 2 gas control Better than ±0.25%O 2 gas control Better than ±0.30%Ambient ConditionsMax/min ambient temperature during operationMax/min storage temperature:Temperature Accuracy (table top)25/20°C55/5°CBetter than ±0.25°C of deviationHumidityMax humidity during operationMax storage humidity75% r.H; non-condensending75% r.H; non-condensendingFiltersInternal Air Quality—Grade A (Air is constantly circulated through HEPA, VOC√filters and a UV Light):Main Filter HEPA (H14 according to DIN EN 1822)VOC FilterHigh-efficiency, acid-washed, granular-activated carbon)Gas Inline FilterDecontamination Programme:50mm HEPA disc filter for the protection of internal circuitsUV Light enclosureUV-C (254 nm)UV-LightUV Light EnclosureUV-C (254nm)IlluminationInternal lampG9—LEDVoltageRated Voltage (system) - VBlower VoltagePowerPower ConsumptionCO2 InletN2 Inlet1/n/PE AC, 110-120V or 220-240V AC 50-60Hz100 V /AC700 VA (Max)1.0 bar / 14.5 PSI1.0 bar / 14.5 PSI10www.k-systems.dk


ivf workstations - l100K-SYSTEMS IVF <strong>Workstations</strong>K-SYSTEMS <strong>Workstations</strong> are dedicated to IVF and the many ARTtechniques. The idea is to achieve the best possible environment forgametes and embryos during the various procedures. This requirescontrol of temperature and humidity in order to maintain correctpH level.K-SYSTEMS <strong>Workstations</strong> offer the possibility to control theseparameters and in addition assure that everything takes place inan aseptic environment, created by a laminar flow with a very lownoise level for your comfort.K-SYSTEMS IVF <strong>Workstations</strong> are offered in three versions.The 100 Series Workstation offers you state of the art technologyand a wide range of options to respond to your specific IVF needsand techniques.The 200 Series Workstation offers a biohazard functionalityproviding simultaneous product and operator protection. Elegantdesign combined with functionality, gives you an optimum solution.The 400 Series Workstation is the entry level range. Itaccommodates the needs of basic IVF procedures in a lean coststructure, without compromising performance or the renownedK-SYSTEMS quality.www.k-systems.dk 11


ivf workstations - l100The 100 Series WorkstationThe 100 Series workstations are designed to meet high expectationsand to respond to specific demands in the IVF process. K-SYSTEMSoffer a variety of models and configuration so your workstation canbe equipped to meet your needs.All workstations have a noise level of only 51 db and an integratedwarmed area (Alu Heat System) in the table top based on a stablecontrolled temperature. Various heating patterns are available. Allworkstations come as standard with K-SYSTEMS heated glass stage.The table top is prepared for one or two stereomicro scopes and lightsource bases. Most stereomicroscopes can be incorporated.Additionally, all models have a gassing and humidification systemintegrated in the back wall with heated gas coming throughtwo nozzles in the table top, making it possible to avoid largefluctuations in CO 2 conditions. The warmed surface is controlledwith the assistance of 3 sensors controlling each heated area.In addition, this series offers a wide range of options which can beincorporated into the workstations (see page 16-17).Available in 4, 5 and 6 foot lengths (120, 150 and 180 cm).Two year warranty.K-SYSTEMS AluHeat TechnologyAluHeat was developed by K-systems and is a result of years ofexperience in manufacturing heat exchangers.AluHeat is an aluminium composite construction with an integratedwarming element and temperature sensors.The warmed mass of aluminium gives off a solid distribution of warmthand secures an even and stable temperature of the table top, which isresistant to thermal shock. Thermal shock is caused by overshooting thetemperature when, for example, a cold element is placed on the tabletop. This typically happens when using electrical heating systems.Advantages such as low maintenance, improved heating of the criticalarea around the light opening, and the absence of a noisy source ofcontamination i.,e. water bath, have proven to be invalauble in morethan 1,500 AluHeat system installed world wide.Some features are standard and some have a list of choices.Additionally, we also offer a variety of options at additional costs.In the following the various:• Models (page 13-14)• Features (page 15-16)• Options (16-17)are described.12www.k-systems.dk


ivf workstations - l100<strong>Workstations</strong> prepared for one Microscope (Stereo or Integrated Microscope)L124 IVFDesigned as a single workspacefor the mounting of a stereomicroscope.Overall dimensions(WxDxH):1246x735x2020mm /49x29x80”L126 IVFDesigned as a singleworkplace and forthe mounting of astereomicroscope, rightsided (standard) or leftsided.Offers adequateworkspace forintegration of moreoptions like anincubator and amonitor in the backwall.Overall dimensions(WxDxH):1846x735x2020mm / 73x29x80”L125 IVFDesigned as a single workplaceand for the mounting ofa stereomicroscope, rightsided (standard) or left sided.Compared to L124 this modelsoffers more table space.Overall dimensions(WxDxH):1546x735x2020mm /61x29x80”L124 ICSIDesigned as one workplaceand prepared for an invertedmicroscope – for performingICSI / IMSI under a laminarflow. The integrated Anti-Vibration table, is workingindependently of theworkstation.Overall dimensions(WxDxH):1246x735x2020 mm /49x29x80”For available options see page 16-17.Standardfeatures:Warmed Glass Stage (not L124 ICSI) The Control Panel The Gassing and Humidification System (not L124 ICSI)www.k-systems.dk 13


ivf workstations - L100<strong>Workstations</strong> prepared for two Microscopes (Stereo and/or Integrated MicroscopeL126 Dual IVFDesigned with two workplaces and for mounting of twostereomicroscopes.A dual workstation offers the potential to simultaneously set up aperfect rotation system / organize division of work and keep theworkflow of individuals undisturbed.Overall dimensions (WxDxH): 1846x735x2020mm / 73x29x80”L126 MPDesigned as two workplaces – the right side is for mountingof a stereomicroscope and left side is dedicated to an invertedmicroscope for performing ICSI / IMSI in clean air. The MP version iscost and space saving by integrating the Anti-Vibration facilities intothe workstation while at the same time giving overall aseptic workconditions.Overall dimensions (WxDxH): 1846x735x2020mm / 73x29x80”For available options see page 16-17.Vertical Laminar Air FlowWarmed Area of the Table Top (not L124 ICSI)Electrical outlet inside the cabinet14www.k-systems.dk


Standard features - L100Standard features forK-SYSTEMS <strong>Workstations</strong> L100SeriesVertical Laminar Air Flow and Low Noise LevelTo create the aseptic workspace, vertical laminar air flow is used.The air flow is filtered through 2 filter systems, a V.O.C pre-filter anda HEPA filter.The K-Systems L100 series IVF Workstation fall in the category ofclass 100 cabinet, where the air flow is taken in from the back ofthe cabinet. The air flow is within the range of 0.31-0.34 m/s duringnormal condition. A low speed mode is available.The system runs at a noise level of only 51 dbThe Warmed Area of the Table TopThe integrated heating system of the table top is an Alu CompositeHeat Exchanger, where the temperature is controlled from thecontrol panel at the table top. The temperature setting can be inCelsius or Fahrenheit.The warmed surface is controlled with the Assistance of 3 sensors/area with a temperature accuracy of ±0.4ºC with a scale runningfrom ambient to 42.9°CVarious heating patterns are available, however please be aware ofadditional costs if standard solution is not chosen. For possibleconfigurations please see below.Please also be aware that if left-sided heating pattern is chosenthere might be limitations in the options that can be offered.Model T-845 R (Standard)Model T-745 R (only L126MP-standard)430 mm430 mm800 mm700 mmModel T-1045 RModel T-1645 R (only L126)430 mm430 mm1000 mm1600 mmBright and ergonomically optimal working conditionsThe table top is made of stainless steel with the warmed areamarked as a slightly darker area. To give the best possible workingconditions, the front of the table top has been shaped with roundededge. This ergonomically shaped edge is made to avoid pressurepoints on the arms of the operator during microscopy.Inside the cabinet the side panels of hardened glass give a brightand user friendly work environment.K-SYSTEMS Alu Composite Heat ExchangerThe integrated warmed area – AluHeat is a result of years ofexperience in manufacturing heat exchangers. AluHeat is analuminium composite construction with an integrated warmingelement and temperature sensors.The warmed mass of aluminium gives off a solid distribution ofwarmth and secures an even and stable temperature of the tabletop, which is resistant to thermal shock. Thermal shock is caused byovershooting the temperature when, for example, a cold elementis placed on the table top. This typically happens when usingelectrical heating systems. Advantages such as low maintenance,improved heating of the critical area around the light opening, andthe absence of a noisy source of contamination i.,e. water bath,have proven to be invaluable in more than 1,500 AluHeat systeminstalled world wide.Each heated area is controlled by 3 sensors providing astable temperature of the entire warmth area.www.k-systems.dk 15


Standard/optional features - L100Warmed Glass Stage and Incorporation of MicroscopesAs embryos are sensitive to temperature fluctuations a controlledheating temperature system is integrated in the microscope lightopening. The system is controlled on the control panel and providesthe highest stability possible of the media in the culture dishesduring microscopy. All L100 series workstations come as standardwith K-SYSTEMS heated glass stage.!Warming Blocks must not be used on the warmed glassstage. This will damage the warmed glass stage.!The table top is prepared for one or two stereo microscopes andlight source bases. Most stereomicroscopes can be incorporated.Optional featuresIncorporated MonitorAn excellent tool for viewing,training and education.The integrated 19” glass paneland high resolution monitorpermit connectivity to amicroscope camera and to anexternal computer.In dual systems, you can switchbetween the two cameras by entering the menu system on thecontrol panel. The viewing panel of glass is designed to secure a nondisturbance of the air flow and is easening the cleaning process.Order Code: 11180Temperature accuracy of +/-0.4ºC. Ambient to 49.9°CThe Control PanelThe control panel is integrated into the table plate, giving easyaccess for the technician. The control panel permits control ofthe following: Fan switch, Alarms, Heat and Temperature settings,Light Source (only K-SYSTEMS Light sources), Light, Timer Function,Various settings.Built in Micro IncubatorReduce the frequency of opening oflarge CO 2 incubators.To optimize your work conditionsinside the work area a 15 ltr MicroIncubator can be an integrated partof your Workstation. The MicroIncubator has two shelves anda two level alarm system. As anoption a glass inner door can besupplied.Order code: 11179The Humidified Gas SystemIn the 100 Series, thehumidified gas system isintegrated in the back wall,using a digital flow meter. Forflushing, the humidified andheated gas is diffused through2 nozzles in the table plate. Tomaintain the pH in the media,glass incubator hoods can beused (optional).Electrical outlet inside the cabinetOne electrical outlet is incorporated as standard for the L124, L125,L126 and 2 outlets for L126 Dual and L126MP.The L100 series is available in 4, 5 and 6 foot lengths (120, 150 and180 cm).Two year warranty.Heated Pass Through TunnelTo improve the work flow andto reduce the time of handlingoocytes in an unheated andunstable environment, the HeatedPass Through Tunnel is a greatalternative to a hatch in the doorbetween the aspiration roomand the embryo lab.The HeatedPass Through Tunnel is made ofstainless steel with integratedheating elements and a top hingedpolycarbonate lid.K-SYSTEMS provides only the Heated Pass Through tunnel withinthe workstation. The hatch in the wall of the building remains theresponsibility of the customer.Order Code: 11167Electrical Adjustable HeightIn search of ergonomics and comfort for the technician, K-SYSTEMS<strong>Workstations</strong> can be supplied with an electrically adjustable heightof the table top. A simple touch button will adjust the height from694 mm to 1094 mm.Only available for L124 IVF.Order Code: 52564 (4-foot model)16www.k-systems.dk


optional features - L100Extra Large Warmed Area in the Table TopAs standard, the table top is partially warmed around the work areaof the microscope. As an option, an extra-large warmed area of theworkstation can be incorporated in the L124, L125 and L126 Single(not possible on L126Dual, L126MP).See page 15 for various heating patterns.Order code: 23052 (L124 and L125)Order code: 52280 (L126)Electrical outlet inside the cabinetOn request, additional electrical outlets can be provided. Numberand placement depends on the type of your Workstation.Order code: 11182UV-LightOn request a UV-light with timer can be incorporated.Order code: 11184Model T-1045 R430 mm1000 mmModel T-1645 R (only L126)430 mm1600 mmExternal Gassing OutletOn request an External Gassing Outlet can be incorporated.Order code: 11181L100 IVF Standard FeaturesL124 L124 L125 L126 L126 L126IVF ICSI IVF IVF Dual MPVertical Laminar Flow X X X X X XV.O.C Pre-filter & HEPA FILTRATION X X X X X XAluHeat technology X X X X XPreparation for a Stereomicroscope Right Side X X X XPreparation for a Stereomicroscope Left Side X X XPreparation for 2 Stereomicroscopes (Right & Left position)XIntegrated Internal Humidification System X X X X XHeating surface with 3 Thermal Sensors per working area ( 6 thermal Sensors in L126 Dual) X X X X XIncorporated K-Systems Heated Glass Stage X X X X XElectrical socket 1 unit Right Side (2 units for the L126 Dual, Right & Left Side) X X X X X XCounter for usage hours of the fans X X X X X XTwo speed for the fan ( High & Low) X X X X X XHEPA Filter Alarm indicating HEPA filter need to be checked X X X X X XPossiblity of switching off the left heated surface in an L126 DualXProgramming for an automactic start up of the workstation X X X X X XControl of the Light Intensity of the K-systems light source from the control panel X X X X XAntiVibration Table (AV5) prepared for one inverted microscope X XL100 IVF Optional FeaturesExternal Humidification System GH01•Extra Large Heated Area • • •Incorporated UV Light • • • • • •Adjustable Height • • • • •Intergration of additional Electrical sockets (Maximum 1 outlets in total per workstation) • • • • •Incorporation of a Light Source LS12 / LS11 • • • • •Integrated Incubator • • • • •Integrated Monitor • • • • •Integrated Tunnel • • • • •Integrated Monitor + Tunnel • •Integrated Incubator + Tunnel • •Integrated Incubator + Monitor • •Not applicable X Standard • Optionalwww.k-systems.dk 17


technical specifications - L100DimensionsOverall Dimensions(W x D x H)L124 L125 L1261246x735x2020 mm -(49x29x80”)1546x735x2020 mm -(61x29x80’’)1846x735x2020 mm -(73x29x80’’)Workspace/tabletop 1226x553mm - (48 x 22”) 1526x553mm - (60 x 22”) 1826x553mm - (72 x 22”)(WxD)Table Height 835 mm/33” 835 mm/33” 835 mm/33”PowerPower Consumption 552 watt 552 watt 988 wattMains Voltage 230VAC or 115VAC 230VAC or 115VAC 230VAC or 115VACMains Frequency 50Hz/60Hz or 60 Hz 50Hz/60Hz or 60 Hz 50Hz/60Hz or 60 HzCurrent 2.4 A or 4.8 A 2.4 A or 4.8 A 4.3 A or 8.6 ASpecificationsWarmed Surface Optional Optional OptionalAluHeat Technology Electrical controlled heating system Electrical controlled heating system Electrical controlled heating systemTemperature Range Ambient to 42.9 °C/109.22°F Ambient to 42.9 °C/109.22°F Ambient to 42.9 °C/109.22°FTemperature Accuracy +/- 0.2 °C +/- 0.2 °C +/- 0.2 °C- Spot variationTemperature Accuracy +/- 0.4 °C +/- 0.4 °C +/- 0.4 °C- overall variationTemperature Set/Read Digital Readout Digital Readout Digital ReadoutLaminar Flow Vertical Vertical VerticalAir FLow 0.32 m/s/11.3 ft/s 0.32 m/s/11.3 ft/s 0.32 m/s/11.3 ft/sMains Power SupplyHeating Rate230V 50 Hz, 230V 60 Hz,or 115V 60 Hz2 ° C / minuteAudible/Visual alarm for filter change outof range tempera ture.230V 50 Hz, 230V 60 Hz,or 115V 60 Hz2 ° C / minuteAudible/Visual alarm for filter change outof range tempera ture.230V 50 Hz, 230V 60 Hz,or 115V 60 Hz2 ° C / minuteAudible/Visual alarm for timer out ofrange tempera ture.PreFilterMain Hepa FilterElectrical OutletsAshrae 52/76 (grav.) corresponding toEUROVENT 4/5 classification EU 3.Classification H-14 with resistance of130 Pa and an efficiency of MPPS of99.995%.Grid on the inlet.Distribution cloth on the outlet.Dimensions: 1214x464x69 mm.Order Code: 11153Max. 2 safety wall sockets - total load 4A Max.Ashrae 52/76 (grav.) corresponding toEUROVENT 4/5 classification EU 3.Classification H-14 with resistance of130 Pa and an efficiency of MPPS of99.995%.Grid on the inlet.Distribution cloth on the outlet.Dimensions: 1514x464x69 mm.Order Code: 11199Required Power 2.4A / 4.8A 2.4A / 4.8A 4.3A / 8.6ASound Level 51 +/- 2 dB(A) 51 +/- 2 dB(A) 51 +/- 2 dB(A)AlarmsAudible/Visual alarm for outof range tempera ture.Audible/Visual alarm for outof range tempera ture.Ashrae 52/76 (grav.) corresponding toEUROVENT 4/5 classification EU 3.Classification H-14 with resistance of130 Pa and an efficiency of MPPS of99.995%. Grid on the inlet.Distribution cloth on the outlet.Dimensions: 1814x464x69 mm.Order Code: 11154Audible/Visual alarm for outof range tempera ture.MaterialFront/Side Windows Polycarbonate/Glass Polycarbonate/Glass Polycarbonate/GlassWorkstation BodyMild Steel Plate EN 10130 DC01(FePO1) Aluminum AW-1050Mild Steel Plate EN 10130 DC01(FePO1) Aluminum AW-1050Mild Steel Plate EN 10130 DC01(FePO1) Aluminum AW-1050Stand - Steel pipes/steelplateMild Steel Tube EN 10219-1Stainless Steel Tube ST1203 ISO127/DIN 2462/ Mild Steel Plate EN10130 DC01(FePO1) Aluminum EN AW-10501Mild Steel Tube EN 10219-1Stainless Steel Tube ST1203 ISO127/DIN 2462/ Mild Steel Plate EN10130 DC01(FePO1) Aluminum EN AW-1050Mild Steel Tube EN 10219-1Stainless Steel Tube ST1203 ISO127/DIN 2462/ Mild Steel Plate EN10130 DC01(FePO1) Aluminum EN AW-1050AluHeat TechnologyAluminiumHeat ExchangerAluminiumHeat ExchangerAluminiumHeat ExchangerTabletop Stainless steel - AISI 304 Stainless steel - AISI 304 Stainless steel - AISI 304Treatment60 µm polyestercoating pretreated tocorrosion class 160 µm polyestercoating pretreated tocorrosion class 160 µm polyestercoating pretreated tocorrosion class 118www.k-systems.dk


ivf workstations - L200The 200 Series <strong>Workstations</strong>The 200 Series are biological safety cabinets - protecting both theproduct and the operator.For maximum protection of the operator against hazardous orpotentially hazardous microorganisms, this microbiological safetycabinet is equipped with a complete air velocity control system.Two HEPA-filters as well as recirculation of the air flow (70%recirculation - 30% Exhaust through HEPA-filter) guarantees thesafety of operator while working at a BioSafety Cabinet. The averageair velocity inside the work chamber is 0.35 m/s. The air velocity ismeasured with an external aneometer inside the work chamber inan horizontal plane according to the EN12469 standards.The control panel is conveniently incorporated into the table plateand easy to reach. The table plate is developed to assure a correctwork position.There are 2 different models to choose from:L 224 - 4 foot (120cm)L 226 - 6 foot (180cm)Options for both models include built-in monitor, electrical socketand incorporated UV-light with timer.The K-Systems BioSafety Cabinets are developed according to thestandards of the EN12469 - one of the most important standards inthe EU for setting the standards for BioSafety Cabinets.As standard, all models have a constant temperature controlledtable top based on the AluHeat Systems – prepared for one or twostereomicroscopes and light bases. All models have as a standardK-SYSTEMS AluHeat TechnologyAluHeat was developed by K-systems and is a result of years ofexperience in manufacturing heat exchangers.AluHeat is an aluminium composite construction with an integratedwarming element and temperature sensors.The warmed mass of aluminium gives off a solid distribution of warmthand secures an even and stable temperature of the table top, which isresistant to thermal shock. Thermal shock is caused by overshooting thetemperature when, for example, a cold element is placed on the tabletop. This typically happens when using electrical heating systems.Advantages such as low maintenance, improved heating of the criticalarea around the light opening, and the absence of a noisy source ofcontamination i.,e. water bath, have proven to be invalauble in morethan 1,500 AluHeat system installed world wide.the K-SYSTEMS warmed glass stage incorporated into the tabletop. As an option we offer a stand alone gassing and humidificationsystem – GH01- making it possible to avoid large fluctuations inCO 2 conditions.For more information on standard features and options please seepage 21-22.The class II workstation from K-SYSTEMS has easy access forcleaning due to the convenient and accessible tray below thetable plate. The advantage is that both microscope light base andmicroscope can remain mounted on the table top during cleaning.Two year warranty.www.k-systems.dk 19


ivf workstations - L200<strong>Workstations</strong> prepared for oneStereomicroscopeL224 IVFDesigned as a single workplaceand for the mounting of astereomicroscope, right sided(standard) or left sided.Overall dimensions (WxDxH):1246x800x2020 mm /49x32x80”L226 IVFDesigned as a single workplaceand for the mounting of astereomicroscope, right sided(standard) or left sided 6 foot,180 cm.Overall dimensions (WxDxH):1846x800x2020 mm /73x32x80”<strong>Workstations</strong> prepared for twoStereomicroscopesL226 Dual IVFDesigned as twoworkplaces and formounting of twostereomicroscopes.A dual workstationoffers the potential tosimultaneously set up aperfect rotation system /organize division of workand keep the workflow ofindividuals undisturbed.Overall dimensions(WxDxH):1846x800x2020 mm /73x32x80”For available options see page 22.Standardfeatures:Warmed Glass Stage The Control Panel Vertical Laminar Air FlowWarmed Area of the Table Top20www.k-systems.dk


Standard features - L200Standard features for K-Systems<strong>Workstations</strong> L200 SeriesVertical Laminar Air FlowTo create the aseptic workspace, vertical laminar air flow is used inall cabinets. In the L200 series the air is recirculated in a HEPA-filtersystem where 70% is being recirculated. 99,995% of all particlesdown to 0,3µ are removed.The Table TopThe table top is made of stainless steel with the warmed areamarked as a slightly darker area. To give the best possible workingconditions, the front of the table top has rounded edge. Thisergonomically shaped edge is made to avoid pressure points on thearms of the operator during microscopy.In the Class II cabinets (200 series) the mean inflow velocity toachieve operator protection is at minimum 0.25 m/s, while themean downflow velocity is 0.30-0.40 m/s.The Warmed Area of the Table TopThe integrated heating system of the table top is an Alu CompositeHeat Exchanger, where the temperature is controlled from thecontrol panel at the table top. The temperature setting can be inCelsius or Fahrenheit.Model T-845 R (Standard)410 mm800 mmK-SYSTEMS Alu Composite Heat ExchangerThe integrated warmed area – AluHeat is a result of years ofexperience in manufacturing heat exchangers. AluHeat is analuminium composite construction with an integrated warmingelement and temperature sensors.Bright and ergonomically optimal working conditionsInside the cabinet the side panels of hardened glass give a brightand user friendly work environment For work space with astereo-microscope there will be a sliding window. If there are nomicroscope preparations - there will be a fixed window.The warmed mass of aluminium gives off a solid distribution ofwarmth and secures an even and stable temperature of the tabletop, which is resistant to thermal shock. Thermal shock is caused byovershooting the temperature when, for example, a cold elementis placed on the table top. This typically happens when usingelectrical heating systems. Advantages such as low maintenance,improved heating of the critical area around the light opening, andthe absence of a noisy source of contamination i.,e. water bath,have proven to be invaluable in more than 1,500 AluHeat systeminstalled world wide.Each heated area is controlled by 3 sensors providing astable temperature of the entire warmth area.www.k-systems.dk 21


Standard/ optional features - L200Heated Glass StageA controlled heating temperature system is integrated in themicroscope light opening. The system is controlled on the controlpanel and provides the highest stability of the media in the culturedishes during microscopy.!Warming Blocks must not be used on the warmed glassstage. This will damage the warmed glass stage.Temperature accuracy of +/-1ºCThe Control PanelTher control panel is integrated into the table plate, giving easyaccess for the technician. The control panel permits control of thefollowing:• Fan switch• Alarms• Heat and Temperature settings• Light Source (only K-systems Light sources)• Light• Timer function• Various settingsOptional featuresIncorporated MonitorAn excellent tool for viewing, training and education.The integrated 19” glass panel and high resolution monitor permitconnectivity to a microscope camera and to an external computer.In dual systems, you canswitch between the twocameras by entering themenu system on thecontrol panel.The viewing panel of glassis designed to secure anon disturbance of the airflow and is easening thecleaning process.Order Code: 11180The Humidified Gas SystemIn the 200 series a stand alone humidified gas system, GH01, canbe offered. The GH01 is plugged into the inner-wall, has a digitalflow meter and a choice of flow rate between 0-50 litres per hour.The flow rate is adjusted on the analog proportional needle valve,positioned on the side of the cabinet for easy access. The waterfor humidification of the gas is heated up to 39,5 °C by a heatingelement. This level of temperature ensures approximately 37,5°C atthe exit point of the supplied length of tubing. For more informationsee page 37.Order Code: 31059Airspeed sensorFor optimal perfomance of the system an airspeed sensor isincorporated, which provides information on when the HEPA-filterrequires changing.UV-LightOn request a UV-light with timer can be incorporated.Available for all series.Order code: 1118422www.k-systems.dk


features - L200L200 IVF Standard FeaturesL224IVFL226IVFL226DualVertical Laminar Flow X X XDouble HEPA FILTRATION X X XAluHeat technology X X XPreparation for a Stereomicroscope Right Side X XPreparation for a Stereomicroscope Left Side X XPreparation for 2 Stereomicroscopes (right & Left position)XHeating surface with 3 Thermal Sensors per working area X X XIncorporated K-Systems Heated Glass Stage X X XIntegrated camera adapter X X XCounter for usage hours of the fans in the Menu System X X XHEPA Filter Alarm indicating HEPA filter needs to be checked X X XProgramming for an automatic start up of the workstation X X XAir Speed Sensor X X XControl of the Light Intensity of the K-systems light source from the control panel X X XL200 IVF Optional FeaturesIncorporation of a Light Source LS14 • • •Integrated monitor • • •Integrated camera Socket 1 unit. ( 2 units for the L226 Dual) Standard is 4 pins socket • • •Incorporated UV Light • • •External Humidification System GH01 • • •Integrated of additional Electrical sockets (max 2) • • •Not applicableXStandard• Optionalwww.k-systems.dk 23


ivf workstations - l400The 400 Series <strong>Workstations</strong>The L400 series accomdates the needs of basic IVF procedures in alean cost structure. Even though there are fewer optional features, itstill guarantees performance and the renowned K-SYSTEMS quality.All workstations have a very low noise level comfort and anintegrated warmed area in the table top based on a stablecontrolled temperature AluHeat System. Various heating patternsare available.The table top is prepared for one or two stereomicroscopes andlight source bases. Most stereomicroscopes can be incorporated.Additionally, all models can be offered with a stand alone gassingand humidification system – GH01- making it possible to avoidlarge fluctuations in CO 2 conditions.K-SYSTEMS AluHeat TechnologyAluHeat was developed by K-systems and is a result of years ofexperience in manufacturing heat exchangers.AluHeat is an aluminium composite construction with an integratedwarming element and temperature sensors.The warmed mass of aluminium gives off a solid distribution of warmthand secures an even and stable temperature of the table top, which isresistant to thermal shock. Thermal shock is caused by overshooting thetemperature when, for example, a cold element is placed on the tabletop. This typically happens when using electrical heating systems.Advantages such as low maintenance, improved heating of the criticalarea around the light opening, and the absence of a noisy source ofcontamination i.,e. water bath, have proven to be invalauble in morethan 1,500 AluHeat system installed world wide.Available in 3, 4 and 6 foots lenghts (90, 120 and 180 cm).Two year warranty.<strong>Workstations</strong> prepared for one StereoMicroscopeL423 IVFDesigned as a singleworkplace and forthe mounting of astereomicroscope,right sided (standard)or left sided.Overall dimensions(WxDxH):946x730x1720 mm /37x29x68”L424 IVFDesigned as a singleworkplace and forthe mounting of astereomicroscope,right sided (standard)or left sided.<strong>Workstations</strong> prepared for twoStereomicroscopesL426 Dual IVFDesigned with twoworkplaces and forthe mounting of twostereomicroscopes.A dual workstationoffers the potential tosimultaneously set up aperfect rotation system /organize division of workand keep the workflow ofindividuals undisturbed.Overall dimensions(WxDxH):1846x730x1720 mm /73x29x68”Overall dimensions (WxDxH):1246x730x1720 mm / 49x29x68”L426 IVFDesigned as a single workplace and for the mounting of astereomicroscope, right sided (standard) or left sided.Overall dimensions (WxDxH):1846x730x1720 mm / 73x29x68”www.k-systems.dk 25


optional features - l400Optional featuresWarmed Glass StageEmbryos are sensitive to temperature fluctuations.A controlled heating temperature system can be integrated in themicroscope light opening. The system is controlled on the controlpanel and provides the highest stability of the media in the culturedishes during microscopy.Order code: 53381!Warming Blocks must not be used on the warmed glassstage. This will damage the warmed glass stage.The Humidified Gas SystemIn the 400 series a stand alone humidified gas system, GH01, canbe offered. The GH01 is plugged in into the inner-wall, has a digitalflow meter and a choice of flow rate between 0-50 litres per hour.The flow rate is adjusted on the analog proportional needle valve,positioned on the side of the cabinet for easy access. The waterfor humidification of the gas is heated up to 39,5 °C by a heatingelement. This level of temperature ensures approximately 37,5°C atthe exit point of the supplied length of tubing. For more informationsee page 40.Order code: 31059Temperature accuracy of +/-0.4ºCUV-LightOn request a UV-light with timer can be incorporated.Available for all series.Order code: 11184The Table Top –Extra Large Warmed AreaAs a standard, the table top is partially warmed around the workarea of the microscope. As an option, an extra-large warmed area ofthe workstation can be incorporated. (not possible on L423 or L426Dual.Order code: 23052 (L424)Order code: 53176 (L426)Electrical outlet inside the cabinetOn request, electrical outlets can be provided. Number andplacement depends on the type of your Workstation.Order code: 11182L400 IVF Standard FeaturesL423IVFL424IVFL426IVFL426DualVertical Laminar Flow X X X XV.O.C Pre-filter & HEPA FILTRATION X X X XAluHeat technology X X X XPreparation for a Stereomicroscope Right Side X X XPreparation for a Stereomicroscope Left Side X X XPreparation for 2 Stereomicroscopes (right & Left position)XHeating surface with 3 Thermal Sensors per working area ( 6 thermal Sensors in L426 Dual) X X X XCounter for usage hours of the fans in the Menu System X X X XTwo speed for the fan ( High & Low) X X X XHEPA Filter Alarm indicating HEPA filter need to be checked X X X XProgramming for an automactic start up of the workstation X X X XControl of the Light Intensity of the K-systems light source from the control panel X X X XL400 IVF Optional FeaturesExternal Humidification System GH01 • • • •Extra Large Heated Area • •Incorporated UV Light • • • •Incorporated K-Systems Heated Glass Stage • • • •90 mm Light source Opening • • • •Electrical socket 1 unit - placed on the left • • • •Intergration of additional Electrical sockets (only L426 Dual-sensor placement) • •Incorporation of a Light Source LS12 / LS11 • • • •Not applicable X Standard • Optionalwww.k-systems.dk 27


technical specifications - l400DimensionsOverall Dimensions(W x D x H)L423 L424 L426/L426D946x730x1720 mm(37x29x68”)1246x730x1720 mm(49x29x68”)1846x730x1720 mm(73x29x68”)Workspace/tabletop (WxD) 940x500 mm (37x20”) 1240x500 mm (49x20”) 1840x500 mm (73x20”)Table Height 835 mm/33” 835 mm/33” 835 mm/33”PowerPower Consumption 483 watt 662 watt 933 wattMains Voltage 230VAC or 115VAC factory set 230VAC or 115VAC factory set 230VAC or 115VAC factory setMains Frequency 50Hz/60Hz or 60 Hz 50Hz/60Hz or 60 Hz 50Hz/60Hz or 60 HzCurrent 2,1 A or 4,2 A 2,9 A or 5,8 A 4,1 A or 8,2 ASpecificationsWarmed Surface Optionel Optionel OptionelAluHeat Technology Electrical controlled heating system Electrical controlled heating system Electrical controlled heating systemTemperature Range Ambient to 42.9 °C/109.22°F Ambient to 42.9 °C/109.22°F Ambient to 42.9 °C/109.22°FTemperature Accuracy +/- 0.2 °C +/- 0.2 °C +/- 0.2 °C- Spot variationTemperature Accuracy +/- 0.8 °C +/- 0.8 °C +/- 0.8 °C- overall variationTemperature Set/Read Digital Readout Digital Readout Digital ReadoutLaminar Flow Vertical Vertical VerticalAir flow 0.40 m/s/14.12 ft/s 0.32 m/s/11.3 ft/s 0.40 m/s/14.12 ft/sMains Power Supply230V 50 Hz, 230V 60 Hz, or115V 60 Hz230V 50 Hz, 230V 60 Hz, or115V 60 HzHeating Rate 2 ° C / minute 2 ° C / minute 2 ° C / minuteAlarmsMain Hepa FilterAudible/Visual alarm for outof range tempera ture.MD50LA-33-GW.The filter efficiency of the mainfilter is 99.999% of particles0.3 µm (D.O.P. test)Order code: 11279Audible/Visual alarm for outof range tempera ture.MD50LA-33-GW.The filter efficiency of the mainfilter is 99.999% of particles0.3 µm (D.O.P. test)Order code: 1153Required Mains Cut-out 2,1 A or 4,2 A 2,9 A or 5,8 A 4,1 A or 8,2 A230V 50 Hz, 230V 60 Hz, or 115V 60HzAudible/Visual alarm for outof range tempera ture.MD50LA-33-GW.The filter efficiency of the mainfilter is 99.999% of particles0.3 µm (D.O.P. test)Order code: 1154MaterialFront and Side Windows Polycarbonate/Glass Polycarbonate/Glass Polycarbonate/GlassWorkstation BodyMild Steel Plate EN 10130 DC01(FePO1) Aluminum AW-1050Mild Steel Plate EN 10130 DC01(FePO1) Aluminum AW-1050Mild Steel Plate EN 10130 DC01(FePO1) Aluminum AW-1050Stand - Steel pipes/steelplateMild Steel Tube EN 10219-1Stainless Steel Tube ST1203 ISO127/DIN 2462/ Mild Steel Plate EN10130 DC01(FePO1) Aluminum EN AW-10501Mild Steel Tube EN 10219-1Stainless Steel Tube ST1203 ISO127/DIN 2462/ Mild Steel Plate EN10130 DC01(FePO1) Aluminum EN AW-10501Mild Steel Tube EN 10219-1Stainless Steel Tube ST1203 ISO127/DIN 2462/ Mild Steel Plate EN10130 DC01(FePO1) Aluminum EN AW-10501AluHeat Technology Aluminium Heat Exchanger Aluminium Heat Exchanger Aluminium Heat ExchangerTabletop Stainless steel - AISI 304 Stainless steel - AISI 304 Stainless steel - AISI 304Treatment60 µm polyestercoating pretreated tocorrosion class 160 µm polyestercoating pretreated tocorrosion class 160 µm polyestercoating pretreated tocorrosion class 128www.k-systems.dk


laminar flow hoodsTechnical specifications:L124 LAFOverall dimensions (WxDxH)L125 LAFOverall dimensions (WxDxH)L126 LAFOverall dimensions (WxDxH)L 423Overall dimensions (WxDxH)L 424Overall dimensions (WxDxH)L 426Overall dimensions (WxDxH)Laminar Flow Hoods1246x735x2020 mm/49x29x80”1546x735x2020 mm/61x29x80”1846x735x2020 mm/73x29x80”946x730x1720 mm/37x29x68”1246x730x1720 mm/49x29x68”1846x730x1720 mm/73x29x68”L100 LAF Standard FeaturesL124LAFL125LAFL126LAFLaminar Flow HoodsThe class 100 line is designed for product protection using verticalair flow.There are 2 different series to choose from:L100 seriesL400 seriesHEPA filters guarantee particle free air. The easy to reach controls,ergonomically shaped table plate, and a very low noise level ensurecomfort for the operator. Not only do all of K-Systems LaminarFlow Hoods adhere to the norms and standards which regulate theindustry, but we continuously strive to improve operator comfortwith respect to ergonomics and noise levels.An elegant design means that not only are these units pleasant tothe eye, but their smooth lines enable quick and easy cleaning.The Laminar Flow Hood based on the L100 series have 3 differentmodels to choose from:L124 LAF (120 cm) - L125 LAF (150 cm) - L126 LAF (180 cm)The laminar flow hoods based on our L400 series have 3 differentmodels to choose from:L423 LAF (90 cm) - L424 LAF (120 cm) - L426 LAF (180 cm)Both Series has an elegant design with a bright and userfriendlywork area.Vertical Laminar Flow X X XV.O.C Pre-filter & HEPA FILTRATION X X XCounter for usage hours of the fans X X XTwo speed for the fan ( High & Low) X X XHEPA Filter Alarm indicating HEPA filter need tobe checkedX X XProgramming for an automactic start up of theworkstationX X XL100 LAF Optional FeaturesIncorporated UV Light • • •Adjustable Height•Intergration of additional Electrical sockets(Maximum 2 outlets in total per workstation)• • •Integrated Monitor • • •L400 LAF Standard FeaturesL423LAFL424LAFL426LAFVertical Laminar Flow X X XV.O.C Pre-filter & HEPA FILTRATION X X XCounter for usage hours of the fans in the MenuSystemX X XTwo speed for the fan ( High & Low) X X XHEPA Filter Alarm indicating HEPA filter need tobe checkedX X XProgramming for an automactic start up of theworkstationX X XL400 LAF Optional FeaturesIncorporated UV Light • • •Electrical socket Maximum 2 units - (placedcenter and/or left)• • •XNot applicableStandard• OptionalThe characteristic of the cabinets are the low level of noise from thefan and the bright work environment.Two year warranty.www.k-systems.dk 29


Biosafety cabinetsBioSafety CabinetsThe 200 Series are biological safety cabinets, for both product andoperator protection. Available in 4 and 6 foot width (120 and 180cm).For maximum protection of the operator against hazardous orpotentially hazardous microorganisms, this microbiological safetycabinet is equipped with a complete air velocity control system. TwoHEPA-filters as well as recirculation of the air flow (70% recirculation- 30% Exhaust through HEPA-filter) guarantees the safety of theoperator while working at a BioSafety Cabinet. The average airvelocity inside the work chamber is 0.35 m/s. The air velocity ismeasured with an external aneometer inside the work chamber in ahorizontal plane according to the EN12469 Standard.The control panel is conveniently incorporated into the table plateand easy to reach. The table plate is developed to assure a correctwork position.Options for both models include built-in monitor, electrical socketand incorporated UV-light with timer.The K-Systems BioSafety Cabinets are developed according to thestandards of the EN12469 - one of the most important standards inthe EU for setting the standards for BioSafety Cabinets.Technical specifications:L 224Overall dimensions (WxDxH)L 226Overall dimensions (WxDxH)BioSafety Cabinets1246x800x2020 mm/49x32x80”1846x800x2020 mm/73x32x80”An elegant design means that not only are these units pleasant to theeye, but their smooth lines enable quick and easy cleaning, due to theconvenient and accessible tray below the table top.L200 Biosafety Standard Features L224 L226Vertical Laminar Flow X XDouble HEPA FILTRATION X XCounter for usage hours of the fans in the Menu System X XHEPA Filter Alarm indicating HEPA filter need to becheckedX XProgramming for an automactic start up of theworkstationX XFixed Window X XL200 Biosafety Optional FeaturesIncorporated UV Light • •Intergration of additional Electrical sockets(Maximum 2 outlets in total per workstation)• •Integrated Monitor • •Air Speed Sensor • •Kit for preparation for connection to external exhaustfilter• •Sliding window - placement of centre of opening (410mm from side; adjustable 280-420 mm from tableplate)• •Placement of openings; horizontally: 410 mm from sidevertical: adjustable 280 to 420 mm from tabletop• •X Standard • Optional30www.k-systems.dk