11.07.2015 Views

k-SySTEMS iVF Workstations

k-SySTEMS iVF Workstations

k-SySTEMS iVF Workstations

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

optional features - L100Extra Large Warmed Area in the Table TopAs standard, the table top is partially warmed around the work areaof the microscope. As an option, an extra-large warmed area of theworkstation can be incorporated in the L124, L125 and L126 Single(not possible on L126Dual, L126MP).See page 15 for various heating patterns.Order code: 23052 (L124 and L125)Order code: 52280 (L126)Electrical outlet inside the cabinetOn request, additional electrical outlets can be provided. Numberand placement depends on the type of your Workstation.Order code: 11182UV-LightOn request a UV-light with timer can be incorporated.Order code: 11184Model T-1045 R430 mm1000 mmModel T-1645 R (only L126)430 mm1600 mmExternal Gassing OutletOn request an External Gassing Outlet can be incorporated.Order code: 11181L100 IVF Standard FeaturesL124 L124 L125 L126 L126 L126IVF ICSI IVF IVF Dual MPVertical Laminar Flow X X X X X XV.O.C Pre-filter & HEPA FILTRATION X X X X X XAluHeat technology X X X X XPreparation for a Stereomicroscope Right Side X X X XPreparation for a Stereomicroscope Left Side X X XPreparation for 2 Stereomicroscopes (Right & Left position)XIntegrated Internal Humidification System X X X X XHeating surface with 3 Thermal Sensors per working area ( 6 thermal Sensors in L126 Dual) X X X X XIncorporated K-Systems Heated Glass Stage X X X X XElectrical socket 1 unit Right Side (2 units for the L126 Dual, Right & Left Side) X X X X X XCounter for usage hours of the fans X X X X X XTwo speed for the fan ( High & Low) X X X X X XHEPA Filter Alarm indicating HEPA filter need to be checked X X X X X XPossiblity of switching off the left heated surface in an L126 DualXProgramming for an automactic start up of the workstation X X X X X XControl of the Light Intensity of the K-systems light source from the control panel X X X X XAntiVibration Table (AV5) prepared for one inverted microscope X XL100 IVF Optional FeaturesExternal Humidification System GH01•Extra Large Heated Area • • •Incorporated UV Light • • • • • •Adjustable Height • • • • •Intergration of additional Electrical sockets (Maximum 1 outlets in total per workstation) • • • • •Incorporation of a Light Source LS12 / LS11 • • • • •Integrated Incubator • • • • •Integrated Monitor • • • • •Integrated Tunnel • • • • •Integrated Monitor + Tunnel • •Integrated Incubator + Tunnel • •Integrated Incubator + Monitor • •Not applicable X Standard • Optionalwww.k-systems.dk 17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!