Chapter 2 - Safety and PrecautionsSafety Instructions2.1 Safety InstructionsSafety Considerations - DC Powered EquipmentCAUTIONCautionRisk of electric shock and energy hazard.Disconnecting one Power Interface Unit (PIU)disconnects only one PIU module. To isolate theBTS completely, disconnect both PIUsATTENTIONRisque de décharge électrique et d'electrocution.La déconnection d'un seul module d'alimentation(PIU) n'isole pas complètement la Station de Base.Pour cela, il faut impérativement débrancher lesdeux modules d'alimentation (PIU).Lithium BatteryRestricted Access Area: The DC powered equipment should only be installed in a Restricted AccessArea.<strong>Installation</strong> Codes: The equipment must be installed according to the latest edition of the countrynational electrical codes. For North America, equipment must be installed in accordance with the USNational Electrical Code and the Canadian Electrical Code.Overcurrent Protection: A readily accessible, listed branch circuit overcurrent protective device, rated40A for the modular BTS, must be incorporated in the building wiring.CAUTION: This equipment is designed to permit connection between the earthed conductor of the DCsupply circuit and the grounding conductor at the equipment.<strong>Installation</strong> instructions:• The equipment must be connected directly to the DC Supply System grounding electrode conductor.• All equipment in the immediate vicinity must be grounded in the same way, and not be groundedelsewhere.• The DC supply system is to be local, i.e. within the same premises as the equipment.• There shall be no disconnecting device between the grounded circuit conductor of the DC source(return) and the point of connection of the grounding electrode conductor.The battery on the NPU card is not intended for replacement by the customer. The NPU module shouldbe sent for battery replacement every 8 years.CAUTIONTo avoid electrical shock, do not perform any servicing unless you are qualified to do so.Line VoltageBefore connecting this instrument to the power line, make sure that the voltage of the power sourcematches the requirements of the instrument.<strong>4Motion</strong> <strong>Installation</strong> <strong>Manual</strong>13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!