• Possible malfuntions •IDEAL 4810-<strong>95</strong>/EP • IDEAL <strong>4850</strong>-<strong>95</strong>/EP • IDEAL <strong>5221</strong>-<strong>95</strong>EP • IDEAL <strong>6550</strong>-<strong>95</strong>EPIDEAL 4810-<strong>95</strong>EP, IDEAL <strong>4850</strong>-<strong>95</strong>EP,IDEAL <strong>5221</strong>-<strong>95</strong>EP, IDEAL <strong>6550</strong>-<strong>95</strong>EPCut cannot be made.• Measurement has not been reachedcorrectly.• LED "S" X does not turn off.Push the S button again.Check the security cover (see page 40).cminch• Measurement below 9 cmHold the S button O until the measurementis achieved.Only IDEAL 4810-<strong>95</strong>EP• Backgauge I does not move and "AB "is shown on the display.Open the clamp E.Turn the hand wheel to the left as far aspossible.• Backgauge I does not advance to position(Hand-wheel has been turned to the left)."AB " is shown on the display. inform service people.IDEAL"Service"None of the above mentioned methodshelped to solve the problem:Contact Service Team under• www.<strong>ideal</strong>.de "Service"service@krug-priester.com- 44 -