<strong>MLX90615</strong>Infra Red Thermometer4 Glossary of TermsPTATPORHFODSPFIRIIRIRDCLPFFOVSDA,SCLTaToESDEMCTBDProportional To Absolute Temperature sensor (package temperature)Power On ResetHigh Frequency Oscillator (RC)Digital Signal ProcessingFinite Impulse Response. Digital filterInfinite Impulse Response. Digital filterInfra-RedDirect Current (for settled conditions specifications)Low Pass FilterField Of ViewSerial Data, Serial CLock – SMBus compatible communication pinsAmbient Temperature measured from the chip – (the package temperature)Object Temperature, ‘seen’ from IR sensorElectro-Static DischargeElectro-Magnetic CompatibilityTo Be Defined5 Maximum ratingsParameter.<strong>MLX90615</strong>Supply Voltage, VDD (over voltage)5VSupply Voltage, VDD (operating)3.6 VReverse Voltage0.5 VOperating Temperature Range, TA-40…+85°CStorage Temperature Range, TS-40…+125°CESD Sensitivity (AEC Q100 002)2kVDC sink current, SDA pin25 mADC clamp current, SDA pin10 mADC clamp current, SCL pin10 mATable 1: Absolute maximum ratings for <strong>MLX90615</strong>Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-maximumratedconditions for extended periods may affect device reliability.3901090615 Page 4 of 30 Data SheetRev 00128/Aug/2008