MLX90615

MLX90615

MLX90615

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MLX90615</strong>Infra Red Thermometer7 Electrical SpecificationsAll parameters are preliminary for T A = 25 ˚C, V DD =3V (unless otherwise specified)Parameter Symbol Test Conditions Min Typ Max UnitsSuppliesExternal supply V DD 2.6 3 3.6 VSupply current I DD No load 0.8 1.5 mASupply current(programming)Power-down supplycurrentPOR levelI DDprNo load, erase/write EEPROMoperations1.5 mAIsleep No load, SCL and SDA high 1.1 3 µAV PORPower On ResetPower-up, power-down andbrown-out0.8 1.5 1.9 VV DD rise time T POR Ensure POR signal 20 msOutput valid Tvalid After POR 0.5 sEEPROMData retention Ta = +85°C 10 yearsErase/write cycles Ta = +25°C 100,000 TimesErase/write cycles Ta = +85°C 40,000 TimesErase cell time Terase 5 msWrite cell time Twrite 5 msPulse width modulationPWM resolution PWMres Data band 10 bitPWM output periodPWM T,H,defFactory default high frequencyPWM, HFO factory calibrated1.024 msPWM output periodPWM T,LLow frequency PWM,HFO factory calibrated102.4 msPWM period stabilitydPWM TInternal oscillator factorycalibrated, over the entireoperation range and supplyvoltage-15 +15 %Output low Level PWM LO I sink = 2 mA 0.2 VOutput sink current Isink PWM Vout,L = 0.5V 10 mA3901090615 Page 6 of 30 Data SheetRev 00128/Aug/2008