Service manual - Logamax plus GB142 (USA/CA) - en - Buderus
Service manual - Logamax plus GB142 (USA/CA) - en - Buderus
Service manual - Logamax plus GB142 (USA/CA) - en - Buderus
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
7DiagnosisRepl. BBpage 3421Check that the tank filling pumpis running.Is the tank fillingpump running?NoCheck that during hot water mode there is a120V AC voltage on the tank filling pump.Yes45page 37Is the tank filling pumpbeing activated?NoCheck the connection board to make sure thatthere is 120V AC on both contacts L and N ofconnection PS (gray) during hot water mode.Yes46page 37Doesthe connection boardhave on both contacts L and N ofconnection PS 120V AC during hotwater operation?YesReplace the supplycord of the tank-fillingpump.NoCheck the fuse on the connection board.Value: 5A. See page 84.Is the fuseon the connection boardokay?YesCheck the cable loom of the device.NoReplace the fuse onthe connection board.See page 84.Is the cable loom okay?YesReplace the circuit board.NoReplace the cableloom.Is the tank filling pumprunning?NoYes44page 838page 3136<strong>Logamax</strong> <strong>plus</strong> <strong>GB142</strong>-24/30/45/60 - We reserve the right to make any changes due to technical modifications!