MS <strong>SE</strong><strong>Short</strong> SurveyStandard typesRetractablesupply systems:SafetyFlexibilityProfitabilityEasy to operateServiceInstallation fields:Market placesPlaces of festivitiesHistorical placesPedestrian precintsGymnasiumsAssembling hallsMulti-purpose hallsHangars


Technical dataInstallation fields:Protection stages:Protection equipment:Mains voltage/Frequency:Kind of voltage:Connection value:Feed in cable max. permissible:Equipment, side AMS <strong>SE</strong> 30A StandardInterior - exterior purposesIP 44 for outletsIP 65 for distributorEarth contact class1230/400 V, 50 HzTN-S Systemapprox. 15 kW5 x 16 mm 21 Distributor, 10 partitions1 elcb 40/0,03 A, 4-pol.1 mcb 16 A, B, 3-pol.2 mcb 16 A, B, 1-pol.1 mcb 2 A, C, 1-pol.(heating)MS <strong>SE</strong> 30 NR StandardInterior - exterior purposesIP 44 for outletsIP 65 for distributorEarth contact class 1230/400 V, 50 HzTN-S Systemapprox. 15 kW5 x 6 mm 21 Distributor, 10 partitions1 elcb 40/0,03 A, 4-pol.1 mcb 16 A, B, 3-pol.2 mcb 16 A, B, 1-pol.1 mcb 2 A, C, 1-pol.(heating)Equipment, side B1 CEE 16 A, 5-pol.2 pieces of earthed outlets1 CEE 16 A, 5-pol.2 pieces of earthed outletsWeightConcrete shaft and shaft insert:Device column equipped:DimensionsConcrete shaft (HxWxD):Cover support/sealing compound:Installation depth:Height of stroke:Space for pavement in cover:The top covering is passable underthe provisions of DIN EN 124:Lifting mechanism:Sewage connections:Order-No.:570 kg30 kg795 x 610 x 885 mm110 mm905 mm233 mm50 mmD 400, 40t Point loadThread spindle2 x DN 40MS <strong>SE</strong> 30A-Sta-01220 kg30 kg1030, Ø 490 mm85 mm1115 mm202 mm20 mmB 125, 12,5t Point loadGas pressure spring/Thread spindle1 x DN 40MS <strong>SE</strong> 30NR-Sta-012


Technical dataInstallation fields:Protection stages:Protection equipment:Mains voltage/Frequency:Kind of voltage:Connection value:Feed in cable max. permissible:Equipment, side AMS <strong>SE</strong> 30IN StandardInterior - exterior purposesIP 44 for outletsIP 65 for distributorEarth contact class1230/400 V, 50 HzTN-S Systemapprox. 15 kW5 x 6 mm 21 Distributor, 10 partitions1 elcb 40/0,03 A, 4-pol.1 mcb 16 A, B, 3-pol.2 mcb 16 A, B, 1-pol.1 mcb 2 A, C, 1-pol. (for heating)MS <strong>SE</strong> 30AN StandardInterior - exterior purposesIP 44 for outletsIP 65 for distributorEarth contact class1230/400 V, 50 HzTN-S Systemapprox. 15kW5 x 6 mm 21 Distributor, 10 partitions1 elcb 40/0,03 A, 4-pol.1 mcb 16A, B, 3-pol.2 mcb 16 A, B, 1-pol.1 mcb 2 A, C, 1-pol. (for heating)Equipment, side B1 CEE 16 A, 5-pol.2 pieces of earthed outlets1 CEE 16 A, 5-pol.2 pieces of earthed outletsWeightConcrete shaft and shaft insert:Device column equipped:DimensionsConcrete shaft (HxWxD):Cover support/sealing compound:Installation depth:Height of stroke:Space for pavement in cover:The top covering is passable underthe provisions of DIN EN 124:Lifting mechanism:Sewage connections:Order-No.:200 kg30 kg410 x 570 x 570mm60 mm470 mm202 mm20 mmB 125, 12,5t Point loadThread spindle2 x DN 40MS <strong>SE</strong> 30IN-Sta-01200 kg30 kg410 x 570x 570mm110 mm520 mm233 mm50 mmD 400, 40t Point loadThread spindle2 x DN 40MS <strong>SE</strong> 30AN-Sta-013


Technical dataInstallation fields:Protection stages:Protection equipment:Mains voltage/Frequency:Kind of voltage:Connection value:Feed in cable max. permissible:Equipment, side AMS <strong>SE</strong> 30AH 500 StandardInterior - exterior purposesIP 44 for outletsIP 65 for distributorEarth contact class1230/400 V, 50 HzTN-S Systemapprox. 15 kW5 x 16 mm 22 Distributors, 10 partitions1 elcb 63/0,03 A, 4-pol.6 mcb 16 A, B, 1-pol.1 mcb 2 A, C, 1-pol. (for heating)Equipment, side B6 CEE 16 A, 3-pol.WeightConcrete shaft and shaft insert:Device column equipped:DimensionsConcrete shaft (HxWxD):Cover support/sealing compound:Installation depth:Height of stroke:Space for pavement in cover:The top covering is passable underthe provisions of DIN EN 124:Lifting mechanism:Sewage connections:Order-No.:450 kg50 kg795 x 610 x 885 mm110 mm905 mm400 mm50 mmD 400, 40t Point loadThread spindle2 x DN 40MS <strong>SE</strong> 30AH 500-Sta-014


Technical dataInstallation fields:Protection stages:Protection equipment:Mains voltage/Frequency:Kind of voltage:Connection value:Feed in cable max. permissible:Equipment, side AMS <strong>SE</strong> 50 StandardInterior - exterior purposesIP 44 for outletsIP 67 for distributorEarth contact class1230/400 V, 50 HzTN-S Systemapprox. 30 kW5 x 16 mm 21 CEE 32 A, 5-pol.1 CEE 16 A, 5-pol.2 CEE 16 A, 3-pol.1 Distributor, 13 partitions1 elcb 63/0,03 A, 4-pol.1 mcb 32 A, B, 3-pol.1 mcb 16 A, B, 3-pol.2 mcb 16 A, B, 1-pol.MS <strong>SE</strong>H 50 StandardInterior - exterior purposesIP 44 for outletsIP 67 for distributorEarth contact class1230/400 V, 50 HzTN-S Systemapprox. 30 kW5 x 16 mm 21 Distributor, 13 partitions1 CEE 32 A, 5-pol.1 CEE 16 A, 5-pol.2 CEE 16 A, 3-pol.1 elcb 63/0,03 A, 4-pol.1 mcb 32 A, B, 3-pol.1 mcb 16 A, B, 3-pol.2 mcb 16 A, B, 1-pol.1 mcb 2 A, C, 1-pol.Equipment, side B7 pieces of earthed outlets1 Distributor, 13 partitions1 elcb 40/0,03 A, 4-pol.7 mcb 16 A, B, 1-pol.1 mcb 2 A, C, 1-pol.(for heating)1 High speed clutchTyp GK GK 1 / 2 “1 Freshwater-shut off valveWeightConcrete shaft and shaft insert:Device column equipped:DimensionsConcrete shaft (HxWxD):Cover support/sealing compound:Installation depth:Height of stroke:Space for pavement in cover:The top covering is passable underthe provisions of DIN EN 124:Lifting mechanism:Sewage connections:Order-No.:620 kg65 kg795 x 610 x 885 mm110 mm905 mm466 mm50 mmD 400, 40t Point loadThread spindle2 x DN 40MS <strong>SE</strong> 50-Sta-03450 kg65 kg795 x 610 x 1036mm110 mm905 mm466 mm50 mmD 400, 40t Point loadThread spindle2 x DN 40MS <strong>SE</strong>H 50-Sta-015


Technical dataInstallation fields:Protection stages:Protection equipment:Mains voltage/Frequency:Kind of voltage:Connection value:Feed in cable max. permissible:Equipment, side AMS <strong>SE</strong> 56 StandardInterior - exterior purposesIP 44 for outletsIP 67 for distributorEarth contact class 1230/400 V, 50 HzTN-S Systemapprox. 50 kW5 x 50 mm 21 CEE 63 A, 5-pol.1 CEE 16 A, 5-pol.3 pieces of earthed outlets1 Distributor, 18 partitions1 elcb 63/0,03 A, 4-pol.1 mcb 63 A, B, 3-pol.1 mcb 16 A, B, 3-pol.3 mcb 16 A, B, 1-pol.MS <strong>SE</strong>H 56 StandardInterior - exterior purposesIP 44 for outletsIP 67 for distributorEarth contact class 1230/400 V, 50 HzTN-S Systemapprox. 40 kW5 x 16 mm 21 CEE 63 A, 5-pol.1 CEE 16 A, 5-pol.3 pieces of earthed outlets1 Distributor, 18 partitions1 elcb 63/0,03 A, 4-pol.1 mcb 63 A, B, 3-pol.1 mcb 16 A, B, 3-pol.3 mcb 16 A, B, 1-pol.1 mcb 2 A, C, 1-pol. (heat.)Equipment, side B1 CEE 32 A, 5-pol.2 CEE 16 A, 5-pol.2 CEE 16 A, 3-pol.1 Distributor, 18 partitions1 elcb 63/0,03 A, 4-pol.1 mcb 32 A, B, 3-pol.2 mcb 16 A, B, 3-pol.2 mcb 16 A, B, 1-pol.1 mcb 2 A, C, 1-pol. (heat.)2 High speed clutchTyp GK 1“ (Freshwater)2 Ball taps(Freshwater-shut off valve)1 High speed clutchStorz 52-C 2” DIN 14037(sewage)WeightConcrete shaft and shaft insert:Device column equipped:DimensionsConcrete shaft (HxWxD):Cover support/sealing compound:Installation depth:Height of stroke:Space for pavement in cover:The top covering is passable underthe provisions of DIN EN 124:Lifting mechanism:Sewage connections:Order-No.:650 kg7 kg965 x 632 x 928 mm110 mm1075 mm520 mm50 mmD 400, 40t Point loadThread spindle2 x DN 40MS <strong>SE</strong> 56-Sta-03710 kg75 kg965 x 632 x 1084 mm110 mm1075 mm520 mm50 mmD 400, 40t Point loadThread spindle2 x DN 40MS <strong>SE</strong>H 56-Sta-016


Technical dataInstallation fields:Protection stages:Protection equipment:Mains voltage/Frequency:Kind of voltage:Connection value:Feed in cable max. permissible:Equipment, side AMS <strong>SE</strong> 80 StandardInterior - exterior purposesIP 44 for outletsIP 55 for distributorEarth contact class 1230/400 V, 50 HzTN-S Systemapprox. 130 kW5 x 150 mm 21 CEE 125 A, 5 pol. 3 Distributor, 10 partitions1 CEE 32 A, 5-pol. 1 elcb 125/0,3 A, 4-pol.1 CEE 16 A, 5-pol. 1 elcb 63/0,03 A, 4-pol.6 pieces of earthed outlets 1 mcb 125 A, C, 3-pol.1 fuse D-02, 63A, 3-pol. 1 mcb 32 A, B, 3-pol.1 mcb 16 A, B, 3-pol.5 mcb 16 A, B, 1-pol.MS SV 80 StandardInterior - exterior purposesIP 44 for outletsEarth contact class1230/400 V, 50 HzTN-C System4 x 150 mm 2 (Feed in cable)until 4 x 50 mm 2 (Leading out cable)Equipment, side BWeightConcrete shaft and shaft insert:Device column equipped:DimensionsConcrete shaft (HxWxD):Cover support/sealing compound:Installation depth:Height of stroke:Space for pavement in cover:The top covering is passable underthe provisions of DIN EN 124:Lifting mechanism:Sewage connections:Order-No.:1 CEE 63 A, B, 5-pol. 3 Distributor, 10 partitions1 CEE 32 A, B, 5-pol. 1 elcb 63/0.3 A, 4-pol.2 CEE 16 A, B, 5-pol. 1 elcb 63/0.03 A, 4-pol.6 pieces of earthed outlets 1 mcb 63 A, B, 3-pol.1 fuse D-02, 63A, 3-pol. 1 mcb 32 A, B, 3-pol.2 mcb 16 A, B, 3-pol4 mcb 16 A, B, 1-pol.1 mcb 2 A, C 1-pol.(for heating)2120 kg80 kg1350 x 1400 x 1110 mm130 mm1480 mm590 mm50 mmC 250, 25t Point loadThread spindle2 x DN 40MS <strong>SE</strong> 80-Sta-014 leading off cableswith NH-00 pre-fuse2120 kg80 kg1350 x 1400 x 1110 mm130 mm1480 mm590 mm50 mmC 250, 25t Point loadThread spindle2 x DN 40MS SV 80-Sta-017


<strong>SE</strong>-Kurz-1003_ETechnical alternations are subject to change without prior notice.Prices subject to change without prior notice. Our terms of deliveryand payment are in validity.i<strong>Moser</strong> <strong>Systemelektrik</strong>Erikaweg 1D-78141 SchönwaldTelefon 0049(0)77 22/96 97-0Fax 0049(0)77 22/96 97-11info@moser-systemelektrik.dewww.senkelektrant.de